BDBG-09 / IT-09T
Detecting unit of gamma radiation BDBG-09 with information panel IT-09T for constant monitoring
Purpose of use:
-measurement of ambient equivalent dose rate (EDR) of gamma radiation;
-displaying of measurement results of ambient equivalent dose rate of gamma radiation (EDR) that have been obtained from the BDBG-09 detecting unit of gamma radiation;
-displaying of current time;
-displaying of ambient air temperature;
-audio and light alarm at threshold levels exceeding of gamma radiation ERD.
Features:
-Data exchange between the detecting unit and the data panel through RS-485 interface;
-Constant self-testing of BDBG-09;
-Availability of the statistical accuracy of measurement;
-Protection jacket of BDBG-09 is IP67;
-Average service life of the detecting unit BDBG-09 is not less than 10 years;
-EDR display range of IT-09T, µSv/h, 0,1...10(7);
-Ambient air temperature display range of IT-09T from - 40 to + 50C;
-The possibility of programming of three threshold levels for IT-09T within the range of 0.01 µSv/h to 9.99 µSv/h with discreteness of 0.01 µSv/h;
-Threshold levels exceeding signaling - audio (with different soundings for every threshold level), and light (color change of EDR measurement result display);
-The possibility of operation in the network via RS485 interface for IT-09T;
-Power supply of IT-09T from industrial network (220 V) through power adapter;
-Operating mode of IT-09T is 24 hours continuous;
-Mounting method of IT-09T is upright wall-mounted.
Delivery kit:
-IT-09T data panel;
-connecting cable;
-power adapter from 220 V network;
-operating manual;
-BDBG-09 detecting unit of gamma radiation kit.
|
|
|
|
|
|
SAM 940 Revealer with Reachback Program
Confidence factors when identifying radioactive materials are critical to a successful mission. To give your end users an edge over traditional identification methods, the latest in MCA and algorithm technology has been coupled with a new detector material for gamma ray collection. The SAM Revealer comes standard with a 1.5%u201D x 1.5%u201D lanthanum bromide detector (LaBr ) and the QCC%u2122 statistical enhancement transform which provides background subtraction in real time and therefore the highest degree of sensitivity. The SAM is designed to operate in any background (high or low), including Bremsstrahlung or Compton, with the interference subtracted in real time (one second or less). With this advanced identifier, your spectroscopic data collection, isotope identification and data analysis reporting are all automated with exceptional resolution. This large improvement in resolution also allows quick identification of mixed radionuclides, a typical problem with the overlapping peaks of lower resolution sodium.
Peak Resolution
One critical specification for gamma ray detectors is peak resolution. In nuclear spectroscopy, we often express the resolution as a percentage at 662 keV (cesium). For the SAM Revealer, the typical resolution is 2.8%. This is about 2.5 times better than sodium iodide detectors and therefore allows separation of many closely spaced peaks.
|
|
| ... products without technical information |
| |
|
|
|
|
HP(Ge) Planar Detectors GPD (Liquid Nitrogen cooled)
APPLICATION
Gamma and X–ray HPGe detector is intended for the conversion of Gamma and X-ray quantum energy to proportional level. This is accomplished using amplitude electric signals and their amplification for further registration with a nuclear physics apparatus. It is also intended for use as the gamma and X-ray detection component of radiological monitoring for environmental objects in nuclear energetics, industrial production, agriculture, medicine, etc.
FEATURES
- Possibility of choosing a preamplifier type with a resistive or opto-electronic feedback high energy rate up to 15000 MeV/sec;
- Ability to increase the energy rate to 20000 MeV/sec radiation detection in any spatial orientation depending on cryostat modification manufacturing in a portable cryostat;
- Possibility of transportation and storage without cooling.
COMPLETE SET
- HP(Ge) coaxial detector (p-type);
- Preamplifier with cooling input stage;
- Cryostat;
- Spectrometric Device;
- Analysis Software;
- Dewar vessel.