General description :
For very special applications, BMG LABTECH offers dedicated plate readers, such as the NEPHELOstar, RUBYstar and LUMIstar OPTIMA. The NEPHELOstar, a laser-based microplate nephelometer, is used for solubility testing of compounds as well as for detection of bacterial growth.
The NEPHELOstar microplate nephelometer detects particles in liquid samples by measuring forward scattered light when a laser beam is directed through the solution. This scattered light is detected at angles of up to 80 degrees, making it approximately thirty times more sensitive than tradional transmission readers that measure the reduction in direct light passing through a sample well.
Flexibily and performance of the NEPHELOstar allow more applications to be adaped to microplate-based laser nephelometry than ever before:
- Automated drug solubility screening
- Microbial growth kinetics monitoring
- Precipitation and polymerization monitoring
|
|
|
|
|
|
The Aurora Nephelometer delivers increased accuracy in studying particulates and their source of origin.
The effects of air pollution on human health and lifestyle are of a major concern today. There are many parameters contributing to air pollution, of which airborne particulates are a major contributor.
Nephelometers give indications of air quality by measuring the light scattering of particles in the air. This translates to visibility measurements and information for global warming studies.
The “new generation” of Aurora nephelometer is available in four models:
Aurora 1000 Nephelometer (single wavelength)
Aurora 2000 Nephelometer (PM2.5 correlation)
Aurora 3000 Nephelometer (3 wavelengths with backscatter)
Aurora 4000 Nephelometer (polar nephelometer)
The wavelengths are characterized as follows:
Blue : 450nm Fine & ultra fine particulates (wood fires, automobiles)
Green : 525nm Visibility (smog, fog and haze)
Red : 635nm Large particulates (pollen, sea salt etc)
Applications
- Visibility Measurements (Airports, City pollution, AAQMS)
- Dust/Sand storm monitoring and early detection networks
- Global warming studies (light scattering/radiation balance)
- Bushfire/pollution monitoring and early detection networks
- PM2.5 mass measurement correlation studies
Features
- Low power instrument (ideal for remote applications)
- Low maintenance
- Low cost of ownership
- Advanced LED light source
- Compact and portable
|
|
POCKET Colorimeter II
More than 30 flexible, single parameter instruments
- Easy operation
- Small enough for almost any pocket
- Reliable results without a mains connection
- Rugged construction yet lightweight
DR 800 series—compact colorimeters
The DR 800 models are preprogrammed for different numbersof tests:
– DR 820: 20 tests
– DR 850: 50 tests
– DR 890: 90 tests
All three DR 800s work best in combination with the practical HACH tests for reliable, fast results in wastewater, drinking water and process water analysis.
|
|
|
|
|
|
WTW has developed a new line of field instruments based on optical measurement offering the following capabilities:
• pHotoFlex: photometry, pH
• pHotoFlex Turb: photometry, pH, turbidity
• Turb 430 IR and Turb 430 T: turbidity
The instruments have been designed to extract the optimum performance from the latest generation optics optics with state-of-the-art LED technology.
Remarkable features include:
• Low power consumption
• Robust
• Display-driven user interface
• Waterproof
• Integrated smart cuvette adapter for 16 and 28 mm cuvettes
• Hand held
The exceptional versatility of the pHotoFlex, pHotoFlex Turb and Turb 430 makes them ideal for use in process control, water analysis, and the beverage industry.
Both pHotoFlex and pHotoFlex Turb are equipped with a pH function, measuring the full pH range from –2.00 to 16.00. The pH measurement is simplicity itself, offering automatic temperature compensation and auto buffer recognition.
For turbidity measurement the Turb 430 IR offers a large range from 0-1100 NT/FNU. Outstanding features include: Automatic 3-point calibration, GLP compliant data export via RS 232, calibration record and the setting of a calibration interval.
|
|
Turbidity Meter LAT-N1
Turbidity Meter LAT-N2
Turbidity Meter LAT-N3
Turbidity Meter ATA-K
Turbidity Meter ATS-K
|
|
The PONSEL turbidimeter allow you the possibility to measure the turbidity without water sampler.
You just have to put the sensor into the water to measure turbidity
Range : 0 - 4 000 NTU in 4 ranges
Meter/Datalogger : Field and lobaoraty instrument
-IP67 watertight
-100 000 data memory
Sensor :
-Infra Red nephelometric technology (ISO 7027 compliance)
|
|
The most important parameters needed for water analysis, especially in drinking water are now available in a portable meter.
You can obtain lab performance in the field by using the HI 93102.
It not only measures turbidity, but also pH, total and free chlorine, bromine, iodine, iron and cyanuric acid (CYS).
All this in the palm of your hand and in seconds!
Measurements are made quickly and repeatedly through a sophisticated, yet easy-to-use microprocessor.
In colorimetric mode, users can select between factory preprogrammed calibration or calibrating the meter on their own, and measure either concentration or relative absorbance of the sample.
Up to 25 measured samples can be stored in memory together with time and date.
|
|
Easy to measure turbidity.
You can easily measure the water turbidity anywhere with this portable sensor because it cannot be affected by external disturbance light.
Unnecessary to draw the water.
You just put the probe into the water to measure turbidity. You can avoid the hassle of drawing the water.
High durability
Controller Unit:
Waterproof IP67. Anti-bacterial metrical is used.
Sensor Unit:
Durable SUS316L is used. Optical window is made of sapphire glass.
It is equipped with a rubber to absorb the impact from wear and shock.
|
|
|
|
|
|
The HD25.2 is a digital turbidity meter for laboratory and mobile use, suitable for measurements in drinking water, beverages, waste water and process liquids. The working principle is based on the nephelometric (90° scattered light sensor) and ratiometric method. It is equipped with three light detectors and two LED light sources (white and infrared) which are permanently kept under control in order to guarantee long-term stability. The instrument performs measurements according to the standards EPA 180.1, ISO-NEPH (ISO 7027), EBC and ASBC. It is also able to carry out measures of transmission factor percentage of white and infrared light. Stabilized power supply and advanced electronics garantee optimal performances over time. The HD25.2 is a datalogger that stores up to 999 samples. The data can be transferred from the instrument connected to a PC via the multi-standard RS232C serial port and USB 2.0. The RS232C serial port can be used to transfer the acquired measurements to a 24 col-
umn printer. The dedicated software DeltaLog11 allows instrument management and data processing on PC.
|
|
TURBIDITY MONITOR MODEL TM2200
Chemtrac's new TruTrac turbidimeter continuously monitors, records, and reports (integrated with SCADA) turbidity compliance data for municipal water filtration processes
FEATURES
- USEPA Method 180.1
- Simplified Calibration utilizes Removable Flow Cell.
- Data Storage and Retrieval as a backup to SCADA
- New all in one Design that Incorporates Debubbling and Display
- Multiple Communication Protocols including Modbus RTU & Modbus TCP (Ethernet)
- Quick Inexpensive Calibration using Same Cells that are used in Laboratory Instruments
- Communicates on same Network as Particle Counters
|
|
The microprocessor-based waterproof TN100 meter is an easy-to-use turbidimeter that meets the rigor of rugged field applications. It is a "must -have" for anyone monitoring turbidity on the go. Using an Infrared light source, it delivers laboratory accuracy with a resolution of 0.01 NTU across an extended range of up to 20 NTU (Nephelometric Turbidity Units).
Product Features :
- IP67 Waterproof and Dustproof - Cleaning and maintenance is simple. It floats!
- Automatic Push-Button Calibration (4 points) for unprecedented full-range accuracy
- Sturdy Carrying Kit complete with 4 calibration standards, 3 empty cuvettes, batteries and comprehensive instruction manual
- Power-saving feature allows over 1200 measurements to be taken with a single set of AAA alkaline batteries
- Large Easy-to-Read Display for optimum viewing of measurements with user-friendly message codes for easy troubleshooting
- Meets Performance Criteria as specified by ISO 1727 (DIN EN 27027) method.
|
|
4-beam pulsed light method
Measuring range 0,01...1000 TE/F
0,01 ... 500 EBC
Connections DN 40, 50, 65, 80, 100
Material st. st., PEEK
Max. pressure 6 bar
Max. temperature 0 ... 80°C (short-time 120°C)
Accuracy +/- 1% FS
Output 4...20 mA
|
|
Orion AQ4500 Turbidimeter
The Orion AQ4500 Turbidimeter offers advanced features not available on any other benchtop or portable turbidimeter. The dual source turbidimeter allows the user to quickly and efficiently measure turbidity in the units of their choice.
Product Detail
Data log capacity of up to 100 data points
Dual source to comply with EPA 180.1 and ISO 7027
Nephelometric and Ratiometric measurements with autoranging
IP67 waterproof portable turbidity meter
Readings in the range of 0 - 1000 NTU with a choice of units: NT, FTU, FNU, ASBC or EBC
Includes turbidity standards kit, rugged carrying case and replacement cuvettes
|
|
The turbidity meter, model 7048-Y, is used for online measurement of turbidity of the condensate, feed water, etc., of power plants.
* Calculates turbidity using transmitted light and scattered light
* The measurement result is directly read on the digital meter. Also, the meter is provided with DC 4 to 20 mA analog signal output.
* Cleans stains from the meter as necessary using a washing brush. (A cleaning interval from 1 to 999 hours may be selected.)
|
|
POCKET Colorimeter II
More than 30 flexible, single parameter instruments
- Easy operation
- Small enough for almost any pocket
- Reliable results without a mains connection
- Rugged construction yet lightweight
DR 800 series—compact colorimeters
The DR 800 models are preprogrammed for different numbersof tests:
– DR 820: 20 tests
– DR 850: 50 tests
– DR 890: 90 tests
All three DR 800s work best in combination with the practical HACH tests for reliable, fast results in wastewater, drinking water and process water analysis.
|
|
|
|
|
|
WTW has developed a new line of field instruments based on optical measurement offering the following capabilities:
• pHotoFlex: photometry, pH
• pHotoFlex Turb: photometry, pH, turbidity
• Turb 430 IR and Turb 430 T: turbidity
The instruments have been designed to extract the optimum performance from the latest generation optics optics with state-of-the-art LED technology.
Remarkable features include:
• Low power consumption
• Robust
• Display-driven user interface
• Waterproof
• Integrated smart cuvette adapter for 16 and 28 mm cuvettes
• Hand held
The exceptional versatility of the pHotoFlex, pHotoFlex Turb and Turb 430 makes them ideal for use in process control, water analysis, and the beverage industry.
Both pHotoFlex and pHotoFlex Turb are equipped with a pH function, measuring the full pH range from –2.00 to 16.00. The pH measurement is simplicity itself, offering automatic temperature compensation and auto buffer recognition.
For turbidity measurement the Turb 430 IR offers a large range from 0-1100 NT/FNU. Outstanding features include: Automatic 3-point calibration, GLP compliant data export via RS 232, calibration record and the setting of a calibration interval.
|
|
|
|