loading in progress... Please wait

www.alphasense.com
Video à traiter ou en cours de traitement (idVideo:En)
Selected product 
gas sensor

Photoionization gas sensor (PID)


With a PID the sample gas is exposed to deep ultraviolet light from a lamp. The emitted light ionises targeted gases in the sample so they can be detected by the gas detector and reported as a concentration (ppb or ppm).

The Alphasense PID can be installed in portable and stationary gas monitors that accept either Alphasense Ltd CH-A3 or other manufactures compatible pellistor cells. Thus providing complete PID capability in a package that has the same dimensional and electrical profile as Pellistors (providing the electronics input circuit is designed to take the sensor’s output range). This opens up an incredible variety of environmental and safety applications in industrial, commercial and residential markets.

The Alphasense PID sensor is offered in two models. They are virtually insensitive to humidity changes, providing unparalleled performance in a variety of applications.

PID-A1 has a linear dynamic range of 100-ppb to 6,000-ppm (Isobutylene).

PID-AH has a linear dynamic range of 5-ppb to 50-ppm (Isobutylene).

The Sensors include a Detector with 10.6eV Lamp, Lamp Driver, Amplifier Circuitry, Removable Electrode Stack & Particulate Filter.

More specifications...

Other products from -

Alphasense

 
back

soc-pmea www di En 2008-07-30-26