RDP Electronics
Group: RDP GROUP

Signal conditioner for LVDT transducer with digital display
0 - 150 Hz | E308/9 RDP Electronics

Signal conditioning is required where the output of a transducer needs to be boosted or changed into a form suitable for the monitor or logging device which will be used. Our digital display units have a built-in monitor device in the form of the digital display as well as analogue output.

Both E308 and E309 have high and low limits with voltage-free relay outputs. The E308 has a shunt calibration facility to enable calibration checks to be made.

A very wide range of gain adjustment ensures that our amplifiers are compatible with the vast majority of LVDT and strain gauge sensors available from any manufacturer.

Although they have a digital display, these units are entirely analogue and are configured using switches and potentiometers, there is no set-up software to learn.
  • zoom



standListOtherProduct www di En 2012-06-23-04