Voltage: 24 V
Current: 0 mA - 250 mA
Pyxis is an analogue amplifer for load cells, microprocessor controlled, compact and easy to use. It is installed on flexographic, rotogravure, cutting, etc. machines to detect the tension of the laminates. Its HW/SW con
Voltage: 0 V - 10 V
Frequency: 1 kHz
... be implemented in one housing for the DIN carrier rail. This means that it can be located either in the switch gear cabinet, or in the immediate neighborhood of the sensor. Users who want to put the ...
Voltage: 0 V - 10 V
Sensor Profibus Module - 9221 The newly developed sensor PROFIBUS module model 9221 is predestined for the integration of various analog sensor output signals into complex, net worked and peripheral automation structures. This module ...
Voltage: 5 V - 10 V
Current: 4 mA - 20 mA
Frequency: 0 Hz - 1,000 Hz
Amplifier Module - 9243 The amplifier module model 9243 is used wherever measurement signals from strain gauges, potentiometric sensors or DC/DC sensors have to be converted into standard signals. Simply ...
Voltage: 20 V - 30 V
Description Four switching points •Four switching points NO / NC programable •Measured value displayed by amplifier APPLICATION: PLANTS & MACHINES | FOOD & BEVERAGES •Four switching points either NO / NC ...
Voltage: 20 V - 30 V
... Output of the analog value as current or voltage •Analog value with cable breakdown protection •Measured value displayed by amplifier APPLICATION: PLANTS & MACHINES | FOOD & BEVERAGES •One switching point either ...
Voltage: 10 V - 30 V
Current: 4 mA - 20 mA
... The DIN mounting rail amplifier GM40 amplifies the signals of SG sensors to output signals conforming to standards. The narrow housing shape allows spacesaving mounting near the sensors ...
Lorenz Messtechnik
Voltage: 12 V - 24 V
Current: 40 mA
... switch between Light ON and Dark ON modes using control wires. The amplifiers can be easily mounted on DIN rails and Is compatible with various fiber optic cables from Autonics.
Voltage: 0 V - 10 V
Current: 0 mA - 20 mA
... isolation of supply Availibility of most common output signals For mounting at DIN EN-mounting rail System adjustment (IMA2 and strain gage sensor) on request IMA2 DMS amplifier ...
Voltage: 0 V - 10 V
Current: 0 mA - 20 mA
... supply Availibility of most common output signals For mounting at DIN EN-mounting rail IMA2-R amplifiers are complete signal processing units for potentiometric transducers and convert ...
Voltage: 0 V - 10 V
Current: 0 A - 20 A
... most common output signals For mounting at DIN EN-mounting rail System calibration (IMA2 and LVDT) on request IMA2 LVDT amplifiers are complete signal processing units for inductive ...
Voltage: 12 V - 24 V
Voltage: 10 V
Current: 4 mA - 20 mA
... series is suitable for use in strain gauges bridge like in 24 bit acquisition circuit, with a programmable gain. The digital amplifier is also utilized in 3 analog outputs, toward a supervision unit. The unit functions ...
ASA-RT s.r.l.
Voltage: 24 V - 230 V
• for all standard signals - with wide-range power supply unit • for snapping onto top-hat rail (DIN EN 50022-35) The isolation amplifier DTVU20 is mainly used for the conversion ...
1CH audio translator module. Supplied with DIN-Rail Mounting adaptor.
3CH audio translator module. Supplied with DIN-Rail Mounting adaptor.
Voltage: 24, 110, 220 V
Current: 25 mA
These units are very versatile as they can be used with all NAMUR, NPN and PNP sensors, functioning with relay ON or OFF load with a timing function in both states. Furthermore they have a programmable time scale from 0,03 seconds ...
Voltage: 12, 110, 220 V
Current: 50 mA
These instruments are made up of a transformer an amplifier and a transistor, a rectifying circuit and one or two output relays with changeover contacts, respectively in the ALNC and ALN2 types. They are used to supply ...
Voltage: 12, 110 V
Current: 25 mA
These instruments are made up of a transformer an amplifier and a transistor, a rectifying circuit and one or two output relays with changeover contacts, respectively in the ALNC and ALN2 types. They are used to supply ...
Voltage: 230, 110, 24 V
Current: 6 A
Frequency: 60, 50 Hz
... One channel (2100) or two channels (2200) design. • Adjustable sensitivity from 1S. • Relay output. • Alarm led. • DIN rail mounting.
Voltage: 230, 24 V
Current: 5 A
Frequency: 60, 50 Hz
... connected, a system of dosage and safety can be realized • Adjustable sensitivity from 10S. • Double relay output. • DIN rail mounting. CONTROL AND ADJUSTMENT Control Disconnect the electrodes ...
Voltage: 24, 230 V
Current: 5 A
Frequency: 60, 50 Hz
... metering, and safety. ● Adjustable sensitivity and delay. ● 2 measuring channels ● Microprocessor technology ● DIN rail mounting
Voltage: 24 V - 260 V
Current: 300 mA
Frequency: 50, 60 Hz
... circuits on the input lines. The configuration dip-switches are easily accessible removing the front panel. Suitable for DIN rail mounting. Technical data: • Supply voltage: see ...
BDC ELECTRONIC S.r.l.
Voltage: 24 V - 260 V
Current: 5 A
Frequency: 50, 60 Hz
... short circuits on the input lines. The configuration dip-switches are easily accessible removing the front panel. Suitable for DIN rail mounting. Technical data: • Supply voltage: ...
BDC ELECTRONIC S.r.l.
Voltage: 24 V - 260 V
Current: 300 mA
Frequency: 50, 60 Hz
... circuits on the input lines. The configuration dip-switches are easily accessible removing the front panel. Suitable for DIN rail mounting. Technical data: • Supply voltage: see ...
BDC ELECTRONIC S.r.l.
Current: 10 mA
... frequency response charge amplifier forms an integral part of the 04 System, and can be interfaced directly with digital displays and vibration analysers. For applications requiring permanent instrumentation, a DIN ...
Voltage: 24, 110, 230 V
Current: 4 mA - 20 mA
Frequency: 50 Hz - 60 Hz
... -proof models Applications - Power supply and switching amplifier for 2-wire transmitters - Switching amplifier for 4-wire active transmitters - Dedicated switching amplifier ...
Voltage: 115, 230, 24 V
ISG-A series: Single channel opto sensors with automatic setting, providing high sensitivity over the full range. ISG-N series: Single channel opto sensors with manual setting, providing high range, high power and dust immunity.
Pantron Instruments GmbH
The Fiber Optic Amplifier is a photoelectric sensor from the FX Series. It is designed with a standardized DIN rail fiber optic for mounting power supplies. This device comes with a Teach-in ...
Voltage: 0 V - 10 V
Current: 4 mA - 20 mA
... can be configured to set thresholds such as net, gross, peak and valley. Powered from a wide ranging DC supply, the DIN rail amplifier is supplied with 2 part screw connectors for ease ...
Voltage: 20 mV - 4,000 mV
Current: 4 mA - 20 mA
The DR7 is a DIN rail mounting amplifier designed to install in suitable cabinets along with other similar devices. To reduce electrical noise, system problems and the risk of accidental ...
Voltage: 0 V - 10 V
Current: 0 mA - 20 mA
EMGZ310.ComACT – Digital Tension Measuring Amplifier with Optional Operation via FMS-comACT App •Free FMS-ComACT app •3 key operation with LCD, simple procedures for offset and calibration. •Detachable terminal ...
FMS Force Measuring Systems AG
Voltage: 207 V - 253 V
Current: 2 A
Power: 2 W
Application: Isolating switch amplifier with intrinsically safe control circuit class [Ex ia] IIC for inductive contacts according to DIN 19234 or NAMUR or mechanical contacts in hazardous industrial ...
Manfred Jünemann Mess- und Regeltechnik GmbH
Voltage: 75 mV - 20,000 mV
Current: 0 mA - 20 mA
LVDT & RVDT Amplifiers Single and multi channel LVDT & RVDT Amplifiers with precise, low-noise standard analogue outputs for industrial applications. Altheris offers a wide range of industrial amplifiers, ...
In-Rail-Bus Power Terminal The 6.2 mm wide IsoPAQ-Connect power terminal is used for supplying the In-Rail-Bus DIN rail connector with supply voltage. Two separate and ...
Voltage: 12 V - 24 V
Current: 0 mA - 20 mA
Power: 5 W
About the TLB Digital Amplifier Weight amplifier and indicator for Omega/DIN rail mounting suitable for back panel; space-saving vertical shape. Key features TLB • ...
Voltage: 0 V - 10 V
Current: 0 mA - 20 mA
... and mains galvanically separated Modular design Housing for DIN rail mounting 12-pole, 82 x 22.5 x 98.8 mm (h x w x d) Brief Description The active universal isolating ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining