Transducer amplifiers

12 companies | 21 products
exhibit your products

& reach your clients in one place, all year round

Exhibit with us
{{#pushedProductsPlacement4.length}} {{#each pushedProductsPlacement4}}
{{product.productLabel}}

{{product.productLabel}} {{product.model}}

{{#if product.featureValues}}
{{#each product.featureValues}} {{content}} {{/each}}
{{/if}}
{{#if product.productPrice }} {{#if product.productPrice.price }}

{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{/if}} {{/if}}
{{#if product.activeRequestButton}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}} {{#each product.productTagAssociationList}}
{{/each}}
{{/each}} {{/pushedProductsPlacement4.length}}
{{#pushedProductsPlacement5.length}} {{#each pushedProductsPlacement5}}
{{product.productLabel}}

{{product.productLabel}} {{product.model}}

{{#if product.featureValues}}
{{#each product.featureValues}} {{content}} {{/each}}
{{/if}}
{{#if product.productPrice }} {{#if product.productPrice.price }}

{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{/if}} {{/if}}
{{#if product.activeRequestButton}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}} {{#each product.productTagAssociationList}}
{{/each}}
{{/each}} {{/pushedProductsPlacement5.length}}
signal amplifier
signal amplifier
2634

Voltage: -10 mV - 10,000,000 mV

... vibration measurements in industrial environments Type 2634 is a compact, two-stage charge amplifier which conditions the output signal from piezoelectric transducers before onward transmission to the measuring/analysis ...

signal amplifier
signal amplifier
IMA2R

Voltage: 0 V - 10 V
Current: 0 mA - 20 mA

... isolation of supply Most common output signals available For DIN EN rail mounting IMA2-R amplifiers are complete signal processing units for potentiometric transducers and convert potentiometric output signals into ...

signal amplifier
signal amplifier
ATA-1372A

Voltage: 35 V - 70 V
Current: 2 A
Power: 70 W

... Product Overview • The ATA-1372A is a constant voltage output wide band amplifier with a bandwidth of DC~3 MHz, a maximum output voltage of 70 Vp-p, and a maximum output power of 70 Wp. • This product features four-quadrant output characteristics, ...

See the other products
Xi'an Aigtek Electronic Technology Co., Ltd.
signal amplifier
signal amplifier
ATA-4011C

Voltage: 80 V - 160 V
Current: 2.12 A
Power: 169.6 W

... ATA-4011C High Voltage Power Amplifier
Maximum Output Voltage: 160Vp-p (±80 Vp)
Maximum Output Power: 169.6Wp
Bandwidth (-3dB): DC~1.2MHz
Slew Rate: ≥426V/μs
RoHS compliant
CE compliant

INTRODUCTION
The ATA-4011C ...

See the other products
Xi'an Aigtek Electronic Technology Co., Ltd.
high-voltage amplifier
high-voltage amplifier
ATA-2022B

Voltage: 0 V - 100 V
Current: 500 mA
Power: 50 W

... Product Overview • The ATA-2022B is a constant high voltage output amplifier with a bandwidth of DC~lMHz, amaximum output voltage of200 Vp-p, and a maximum output power of 50 Wp • This product features four-quadrant output characteristics, ...

See the other products
Xi'an Aigtek Electronic Technology Co., Ltd.
power amplifier
power amplifier
MP108

Voltage: 200 V
Current: 10 A
Power: 100 W

... The MP108 is a 10A, 200V power operational amplifier that features a very high 300kHz of power bandwidth for piezoelectric actuator and transducer drive applications. The MP108 has optional features such as four-wire ...

See the other products
Apex Precision Product
signal amplifier
signal amplifier
E308, E309

Voltage: 5 mV - 90,000 mV
Current: 60 A - 100 A

... Signal conditioning is required where the output of a transducer needs to be boosted or changed into a form suitable for the monitor or logging device which will be used. Our digital display units have a built-in monitor device in the ...

signal amplifier
signal amplifier
LCA-460

Voltage: 0.63 mV - 640 mV
Current: 0 mA - 20 mA

... LCA-460 Strain Amplifi er Signal Conditioner Modules for Strain Gages Transducers LCA-460 strain amplifier signal conditioner is ideal for applications wherein high performance signal conditioning is needed, and critical ...

isolation amplifier
isolation amplifier
TR225

Voltage: 0 V - 10 V
Current: 0 mA - 20 mA

... • Isolating amplifier for implementation on standard signals • Galvanic isolation between input, output and power supply • About 18 Vdc unregulated supply voltage, max. 25 mA • Supply voltage 230 Vac/115 Vac • Plastic housing for ...

sound amplifier
sound amplifier
HIFU

Power: 20 W - 500 W
Frequency: 500 kHz - 5,000 kHz

... HIFU multi-channel amplifier For user applications: - Histotripsy - Thermal ablation - Sonodynamic therapy - Therapeutic delivery - Sonoporation - Gene therapy - Cardiology - Neurology - Oncology - Cleansing Our amplifier, ...

power amplifier
power amplifier
STV 22 GL

Voltage: 20 V - 253 V
Current: 0 mA - 20 mA

... The STV 22 GL isolating amplifier with supply is used for the galvanic isolation and amplification of DC signals (mA). Description The connected transducer is directly supplied by means of a galvanically isolated ...

signal amplifier
signal amplifier
AMPLI-Block

Voltage: 24 V
Current: 4 mA - 20 mA

... AMPLI-Block is a load cell/ transducer amplifier. AMPLI-Block offers many benefits in a compact design such as very easy set up and two outputs (one with adjustable filter). AMPLI-Block may be used with one or two load ...

in-line amplifier
in-line amplifier
iAMP2™ series

Voltage: 0 V - 10 V
Current: 0 mA - 1 mA

... compact amplifier module that connects 'inline' via cables with standard industrial connectors, or via cables with flying leads and connectors, to DFE tension transducers Model Ti22 iAmp2's function is to convert ...

signal amplifier
signal amplifier
ME131871-00

Voltage: 50, 2 mV
Current: 4 mA - 20 mA

... AMPLI-Block is a load cell/ transducer amplifier. AMPLI-Block offers many benefits in a compact design such as very easy set up and two outputs (one with adjustable filter). AMPLI-Block may be used with one or two load ...

exhibit your products

& reach your clients in one place, all year round

Exhibit with us
DirectIndustry RFQ: Free quotation comparison tool
Receive and compare quotations for free
Describe your project
We select
the best suppliers
Compare quotations and complete your purchase