• Thermoplastic enclosure
• 2 contacts
• Mounting details to EN 50041
• Compact design
• Wire length up to 10 m
• Release by push button (VD)
• Available without unlocking mechanism (to EN 60947-5-1)
• Wire pull and breakage detection Applied standards - EN 60947-5-1, EN 60947-5-5, EN ISO 13850, EN ISO 13849-1
Enclosure - thermoplastic, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0
Cover - thermoplastic, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0
Degree of protection - IP 67 to IEC/EN 60529
B10d (10 % load) - 200 000
TM - max. 20 years
Contact material - silver
Switching elements - 1 NC/1 NO contact or 2 NC contacts, type Zb
Switching system - snap action, positive break NC contacts
Connection - screw connection terminals
Cable cross-section - min. 0.5 mm², max. 2.5 mm² (incl. conductor ferrules)
Stripping length - 6 mm