- Electricity - Electronics >
- Switch and Relay >
- Technology switch
Technology switches
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}

Primary current: 1,500 mA
Voltage: 24 V
Operating temperature: -25 °C - 70 °C
... required to enable this fine positioning. Furthermore, the sensor box also integrates four shielded tracks in latching reed technology. As such, the sensor box can be installed with ease with just ...
SCHMERSAL

Primary current: 0 mA - 250 mA
Voltage: 0 V - 110 V
The Schmersal thermoplastic enclosure non-contact safety switch mounts easily with four screws. There is no protruding of the actuator which measures 119,5mm x 140mm x 43,3mm. The symmetrical design is suitable for ...
SCHMERSAL

Primary current: 0.6 A
Voltage: 32 V
• - Thermoplastic enclosure • - Electronic contact-free, coded system • - Misaligned actuation possible • - 27 mm x 108.2 mm x 35 mm • - High repeat accuracy of the switching points • - Max. length of the sensor chain 200 m • - ...
SCHMERSAL

Sensors as part of the safety equipment can be used to monitor safety doors as well as other detachable guards. These sensors are useful in making complementary NO/NC contact as well as equivalent and includes two as well as three N/O ...
SICK

Voltage: 6 V - 28 V
Operating temperature: -40 °C - 150 °C
Automotive 2ch 45 mΩ High-Side Switch with Variable OCD and OCD Mask Function BV2HD045EFU-C is a 2-ch high-side switch for automotive application. It has built-in over current protection function, thermal ...

Primary current: 3 A
Voltage: 3 V - 5.5 V
Operating temperature: -40 °C - 150 °C
The BM2LC120FJ-C is an automotive 2ch low side switch IC, which has built-in OCP, TSD, active clamp function. Also, diagnostic function can diagnose OCP, TSD, open load detection function (OLD). AEC-Q100 Qualifies(Grade1) ...

Primary current: 3 A
Voltage: 30, 125, 250 V
... to electric switches) use a standard miniature single pole double throw (SPDT) electrical switch which is UL, SEMKO, VDE and CSA certified. The range of switch models includes #10-32, M5, manual, female ...

Primary current: 15 A
Voltage: 120, 240, 480 V
The CLIPPARD ES-1 Series Switches are designed primarily to coincide with the MPA series actuators. Made from high-grade materials, it ensures serviceability and reliability in delivering optimum results. Its portability makes it easy-to-install ...

Primary current: 5, 3 A
Voltage: 125, 250, 30 V
... sub-miniature air switches. These one of a kind switches use a standard sub-miniature single pole double throw electrical switch certified UL and CSA. These highly flexible and reliable switches also have mechanically-operated ...

Keithley System S46 and S46T RF Microwave Switch Systems S46 and S46T Microwave Switch Systems are designed to simplify the automated switching needed to test a wide range of RF and telecommunication ...

Interface RF Connectors with Switch, 3.9mm Height, DC to 6GHz Interface RF Connector with Switch, 3.9mm High, DC to 6GHz 1. Low insertion loss Typically, 0.08dB at 1GHz Typically, 0.1dB at 2GHz 2. ...

Primary current: 0.1 A - 26 A
The Honeywell Micro Switch is globally compliant and established worldwide for its extended life and repeatability. The technology was originally developed in WW II to support US aircrafts. Advancements ...
Honeywell Advanced Sensing Technologies

Honeywell MICRO SWITCH TP rocker switches are designed for flush mount to the panel for a low profile button or above panel for a distinctive button appearance. The buttons are removable and interchangeable and are available ...
Honeywell Advanced Sensing Technologies

Full-Scale Offering. Clean Slate Engineering. Optimal operator interface for controlling machine function to construction and agriculture equipment OEMs, in addition to aerospace, air transport, armored fighting vehicles. Honeywell toggle ...
Honeywell Advanced Sensing Technologies

... because when stopping a machine, the actuator that is connected to machine guard is detached from head switch. Intended for heavy loaded industrial machines with fast rundown time. The device comes with ...
Telemecanique Sensors

... the switch lid. This switch is also available in 316 stainless steel and is suitable for external use, applications where there are hygiene requirements, and other situations where a level of corrosion ...
Allen-Bradley

Primary current: 6, 3 A
Voltage: 250, 230 V
Operating temperature: -20 °C - 90 °C
... self-extinguishing UL 94 V-0 Degree of protection - IP 65 to IEC/EN 60529 B10d (10 % load) - 200 000 TM - max. 20 years Switch insert - 1 x Ex 14 Contact material - silver Switching system - slow action, positive ...
steute Schaltgeräte

Coded magnetic switches are available in a variety of types. They offer amazing protection against tampering. Made of sturdy plastic, the switches are available with 9m, 6m and 3m cable or connector versions. Switching distances are 4mm ...

Primary current: 25 mA
Voltage: 3 V - 6 V
Operating temperature: -30 °C - 85 °C
X4 with Micro-MaTch socket or FFC connector. High performance, hall-sensed switch for various coding, with mechanical and electrical interfaces, up to 20 Ncm switching torque and optional push function.

Primary current: 0.2, 0.1 A
Voltage: 28 V
Operating temperature: -45 °C - 85 °C
... Shaft Material - Stainless steel Shaft Outer Diameter - 3.2 Shaft Outer Diameter Unit - mm Signal / Coding - Selector Switch Switching Mode - Shorting, Non-shorting Switching Torque - 3 Ncm, 6 Ncm Switching Voltage - < 28 VDC

Voltage: 230 V
... case, a safety gate system with guard locking is the right solution for you. Get to know the big brother of the safety switch PSENmech: The mechanical safety gate system PSENmech with guard locking also holds the ...

Voltage: 105 V - 130 V
OPTO-TOUCH Optical Touch Buttons are zero-force ergonomic replacements for mechanical push buttons. Momentary-action touch buttons with electromechanical relay or solid-state outputs.

Voltage: 12 V - 30 V
... job light Require no physical pressure to operate, eliminating hand, wrist and arm stresses associated with repeated switch operation Offers a cost-effective and easy-to-install pick-to-light solution for areas ...

... dirt and are more accommodating to misalignment than mechanical switches Compact size makes it possible to conceal the switch Three housing styles are available for flat or 30 mm barrel-style mounting All ...

Primary current: 1 mA - 5,000 mA
Voltage: 12 V
Operating temperature: -40 °C - 120 °C
Johnson Electric’s automotive switch product line under the Saia-Burgess brand sets a new standard for high reliability in door locking systems. The technology leading line of L16 microswitches increases ...
Johnson Electric

Primary current: 8, 10, 15 A
Voltage: 28, 250, 125 V
Operating temperature: 0 °C - 85 °C
1500/2500 Series rocker switches are available as Midsize Non-Illuminated and Illuminated, and Hi-Lite Rocker with High Inrush. The 1500H/2500H High Inrush option is designed to handle high inrush currents up to 100A peak inrush for 10 ...
Eaton Commercial Controls

Primary current: 50 mA - 100 mA
Voltage: 5 V - 35 V
The locking systems we use were created according to the DIN EN 1303 standard by well-known lock manufacturers. They are open, mechanical systems which, depending on the environmental conditions, require occasional maintenance (e.g. greasing ...
RAFI GmbH & Co. KG

Primary current: 1 A - 10 A
Voltage: 250, 125, 50, 30 V
The DC contact block is used for signalling and annunciation applications. The snap-action mechanism prevents slow contact opening when the plunger is operated slowly. Quenching of the arc that occurs with DC is supported by two-capacity ...

Primary current: 1 A - 10 A
Voltage: 125, 250, 30, 50 V
The Cam Controller NU 1 is used as a signal and annunciation switch in HV systems. This rugged switching device has cam discs made of insulation material that can be set at 10° intervals. The DC contact blocks are designed ...

... green, OFF: red) IP67 protection structure (IEC standard) SIL 3, PL e rating when used with SFC-N series safety non-contact switch controllers Korea Patent Registration 10-2124203, U.S.A. Patent Registration 16/477358, ...

The MN series magnetic non-contact switches utilize magnetic type detection to monitor opening and closing of actuator doors. The switches can be installed vertically or horizontally, and can also be installed from both sides. Main ...

Primary current: 1 mA - 50 mA
Voltage: 0 V - 30 V
Operating temperature: -20 °C - 55 °C
Benefits for you Safety switch with integrated mounting magnet for process protection (without guard locking monitoring) Integrated CES-AR electronics A special evaluation unit is not required ...
EUCHNER GmbH + Co. KG

Primary current: 80 mA
Voltage: 24 V
Operating temperature: -20 °C - 55 °C
Non-contact safety switch CES-A-C5... • Safety switch with integrated evaluation electronics • Pulsed signals can be switched • 2 safety outputs (semiconductor outputs) • Category 3 / PL e according ...
EUCHNER GmbH + Co. KG

Primary current: 0.25 A - 8 A
Voltage: 300 V
Non-contact safety switch CES-AP-C01-... • Safety switch with integrated evaluation electronics • No series connection • Short circuit monitoring • 2 safety outputs (semiconductor outputs) • Category ...
EUCHNER GmbH + Co. KG

Primary current: 1 A - 3 A
Voltage: 240, 230, 120, 110 V
... Annex K - Double break contacts: High electrical rating due to solid contact bridge and double break contacts - Precision switch: High switching accuracy and resistance to shock and vibration - Magnetic blowout: Optional ...
Schaltbau GmbH

Primary current: 0.5 A - 5 A
Voltage: 60, 120, 230, 240 V
... against the fixed contacts. During each operation this wiping action results in the self-cleaning of the contacts. And it is the switch with gold contacts that makes the most of this effect. Features: - Double break ...
Schaltbau GmbH

Primary current: 1 A - 5 A
Voltage: 110, 120, 230, 240 V
... and vibration resistance. So the typical field of application is medium-voltage switchgear and controlgear. The S820 Series switch is a Form Z SPDT with double-break contacts. Its two mechanically linked rigid contact ...
Schaltbau GmbH

The railway professional. The FBS, a special version of the VNS0, is a switch developed for travel and braking operations used in trams and numerous other railway vehicles. It has been field-tested in practice over ...

On/off switch GS On/off switches according to utilisation category AC-23 (switching of motor loads or other highly inductive loads) according to DIN VDE 0660 Part 100. The regulations in DIN VDE 0113 Part 1 and EN 60204 ...

The Safemaster STS engineered by Dold, is a safety interlock switch that features a complete safety concept. This device offers users a standard expandable system and is composed of a durable stainless steel construction. ...

This product features a 30.5 mm cut out panel and is able to travel a distance of 6 mm. Adding to this, it offers IP66/IP69K lkevel of protection and houses a fairly big touch surface. The user is able to choose between various types ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining