- Electricity - Electronics >
- Switch and Relay >
- Technology switch
Technology switches
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 1,500 mA
Voltage: 1 kV
Diameter / length: 125 mm
... Magnetic track sensor box 4 tracks, 2 optional for fine positioning optional fine positioning tracks with prewarning indication Maintenance-free signal storage and switching in case of power failure Wide angle LED track display ...
SCHMERSAL
Primary current: 0 mA - 250 mA
Voltage: 0 V - 100 V
Diameter / length: 43.3 mm
... Thermoplastic enclosure Non-contact safety switch Does not protrude into the door opening 119,5 mm x 140 mm x 43,3 mm Substitutes door-handle and safety switch, ...
SCHMERSAL
Primary current: 100 A
Voltage: 0.8 kV
Diameter / length: 35 mm
... Max. length of the sensor chain 200 m 2 short-circuit proof PNP safety outputs Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet ...
SCHMERSAL
Voltage: 105 V - 130 V
... OPTO-TOUCH Optical Touch Buttons are zero-force ergonomic replacements for mechanical push buttons. Momentary-action touch buttons with electromechanical relay or solid-state outputs. ...
Voltage: 12 V - 30 V
... Replaces capacitive touch switches and mechanical push buttons Features illuminated base (to provide a bright, easy-to-see job light) solid, flashing or multiple color models available Offers choice of models with red, green ...
... risk of intentional defeat Magnets with different polarizations add security For safety applications, switch must be used with Banner safety controllers or GM-FA-10J safety ...
... Interface RF Connectors with Switch, 3.9mm Height, DC to 6GHz Interface RF Connector with Switch, 3.9mm High, DC to 6GHz 1. Low insertion loss Typically, 0.08dB at 1GHz Typically, 0.1dB at 2GHz 2. Space saving ...
Voltage: 230 V
... The mechanical safety switches PSENmech are suitable for safe monitoring of a movable guard. If guards are opened, the safety switches PSENmech are tripped. The hazardous machine movement ...
Primary current: 25 mA
Voltage: 3.2 V - 5.5 V
Diameter / length: 6 mm
... High performance, hall-sensed switch for various coding, with mechanical and electrical interfaces, up to 20 Ncm switching torque and optional push function Product Features Hall Sensed Switch Various ...
Primary current: 0.1, 0.2 A
Voltage: 28 V
Operating temperature: -45 °C - 85 °C
... Highly robust Ø 1/2" selector with 22.5° indexing angle, up to 6 Ncm switching torque and operating temperature from -45 to 85° C Product Features 22.5°, 30° or 36° indexing angle Qualified by MIL-STD-202G Gold plated contacts ...
... Magnetic Safety Sensors BERNSTEIN offers the user coordinated coded magnetic switches and corresponding actuators. With suitable evaluation (e.g. BERNSTEIN MÜZ), the sensor fulfils the requirements of DIN EN 60947-5-3 ...
... Coded magnetic switches are available in a variety of types. They offer amazing protection against tampering. Made of sturdy plastic, the switches are available with 9m, 6m and 3m cable or connector versions. Switching ...
... Specifications General data Maximum matrix size - 192x192 Matrix configurations - NxN, MxN, NxCC Optical switch options - OPMs VOA Shutter Fiber type - Singlemode ...
... Cable Pull Switches can be installed along or around awkward machinery such as conveyors and provide a constant emergency stop access. The system includes a rope status indicator and emergency stop button mounted on the switch ...
Allen-Bradley
... switches, 2-way switches (transfer switches) or step switches with electrically controlled or manual operation. SPINNER 2-way switches use a hypocycloidic gear. This technology makes ...
Primary current: 0.5 A - 1.2 A
Voltage: 2.7 V - 5.5 V
... Low-resistance power load switches offer reliable overcurrent and thermal protection. They are designed for general-purpose power protection or for applications such as USB, hot-swap and power distribution. The power switches ...
STMicroelectronics
Voltage: 6 V - 28 V
Operating temperature: -40 °C - 150 °C
... Automotive 2ch 45 mΩ High-Side Switch with Variable OCD and OCD Mask Function BV2HD045EFU-C is a 2-ch high-side switch for automotive application. It has built-in over current protection function, thermal shutdown protection ...
ROHM Semiconductor
Primary current: 16 A
Voltage: 690, 220 V
Operating temperature: -20 °C - 60 °C
... pole OFF switch or changeover switch Enclosure made of optical fibre reinforced polyester resin Degree of protection IP66 according to IEC/EN 60529 Clear position indicator 0/1 or ON/OFF Functional Description - ...
Primary current: 1 A - 6 A
Voltage: 240, 125, 24 V
... The S840 snap-action switch is a high-quality microswitch in a conventional design. The mechanical positive opening ensures the opening of the switch, even if the contacts have been fused by a short circuit. The self-cleaning ...
Schaltbau GmbH
Primary current: 10, 16, 22, 6 A
Voltage: 250, 125 V
Operating temperature: 0 °C - 85 °C
... wide circuit in standard or custom colors for illuminated and non-illuminated versions. Custom legends are available on the switch lever and bezel. The 1600H/2600H High Inrush option is designed to handle high inrush currents up to 100A ...
Eaton Commercial Controls
Primary current: 120, 90, 200, 250 mA
Voltage: 24, 28, 12, 15 V
... Latching/Failsafe, SPDT, 50Ω impedance Available in Commercial and Elite models, with 2.92mm connectors. DC-40GHz ...
Teledyne Relays
Primary current: 0.01 mA - 100 mA
Voltage: 0 V - 35 V
Diameter / length: 15 mm
... The RF 15 gold tactile switches have a 15 x 15 mm edge length, reliable gold contacts and a noticeable click. They are used in flat data entry keyboards under overlays or under keycaps, such as RAFI RK 90 keycaps. Flat data entry keyboards ...
RAFI GmbH & Co. KG
Primary current: 5 A
Voltage: 220 V
Diameter / length: 25 mm
... Applications of the
switch:
Widely used in various household appliances, medical devices, military industries, electronic equipment, automation equipment, communication equipment, automotive electronics, power tools, and other ...
Yueqing Tongda Wire Electric Factory
Diameter / length: 160 mm
Height: 240 mm
... strictly forbidden to connect the magnetic switch directly with the power supply, and it must be used in series with the load (such as a relay, etc.). (3) Before selecting and connecting the magnetic switch, confirm ...
Yueqing Tongda Wire Electric Factory
Primary current: 5, 10 A
Voltage: 125, 250 V
Diameter / length: 37.1 mm
... -5A-006-TD1 is a miniature solderable switch designed for compact electrical control applications. It is offered with rated current options 5(2)A and 10(3)A and rated voltages AC 125V / 250V and DC 30V. The switch is ...
Yueqing Tongda Wire Electric Factory
Primary current: 250 mA
Voltage: 24 V
Operating temperature: -20 °C - 60 °C
... machinery Contactless coded electronic sensor Total safety management with an AWAX controller Low cost solution for multi-access applications Level of performance with AWAX controller: up to PL = e Safety category: ...
COMITRONIC - BTI
Diameter / length: 1 mm - 3 mm
Operating temperature: -25 °C - 70 °C
... door holding • Contactless coded electronic sensor • Total safety management with an AWAX controller • Level of performance with AWAX controller: up to PL = e • Safety category: up to 4 with an AWAX ...
COMITRONIC - BTI
Operating temperature: -40 °C - 125 °C
... • Safety category: up to 4 with an AWAX controller • Time before dangerous failure: MTTFd = 100 years • Max. activation distance: 3 mm, 1 mm hysteresis • Holding Force: transmitter + receiver in contact = 20N ...
COMITRONIC - BTI
Primary current: 1 A - 10 A
Voltage: 50, 125, 30, 250 V
Operating temperature: -40 °C - 85 °C
... The DC contact block is used for signalling and annunciation applications. The snap-action mechanism prevents slow contact opening when the plunger is operated slowly. Quenching of the arc that occurs with DC is supported by two-capacity permanent magnets. These ...
Primary current: 1 A - 10 A
Voltage: 50, 30, 250, 125 V
Operating temperature: -40 °C - 85 °C
... The Cam Controller NU 1 is used as a signal and annunciation switch in HV systems. This rugged switching device has cam discs made of insulation material that can be set at 10° intervals. The DC contact blocks are designed to permit series ...
Primary current: 1 mA - 50 mA
Voltage: 0 V - 30 V
Operating temperature: -20 °C - 55 °C
... Safety switch with integrated mounting magnet for process protection (without guard locking monitoring) Integrated CES-AR electronics A special evaluation unit is not required Up to 20 AR devices can be connected in ...
EUCHNER GmbH + Co. KG
Primary current: 80 mA
Voltage: 24 V
Operating temperature: -20 °C - 55 °C
... switched • 2 safety outputs (semiconductor outputs) • Category 3 / PL e according to EN ISO 13849-1 • Unicode Approach direction Can be adjusted in 90° steps Unicode evaluation Each actuator is highly coded (unicode). The switch ...
EUCHNER GmbH + Co. KG
Primary current: 0.25 A - 8 A
Voltage: 300 V
... monitoring • 2 safety outputs (semiconductor outputs) • Category 4 / PL e according to EN ISO 13849-1 • M12 plug connector 5-pin; pin 5 not used • Unicode Approach direction Can be adjusted in 90° steps Short circuit monitoring The ...
EUCHNER GmbH + Co. KG
Primary current: 3 A
Voltage: 30, 125, 250 V
... Clippard MAS series switches (air to electric switches) use a standard miniature single pole double throw (SPDT) electrical switch which is UL, SEMKO, VDE and CSA certified. The range of switch models ...
Primary current: 15 A
Voltage: 120, 240, 480 V
... The CLIPPARD ES-1 Series Switches are designed primarily to coincide with the MPA series actuators. Made from high-grade materials, it ensures serviceability and reliability in delivering optimum results. Its portability makes it easy-to-install ...
Primary current: 5, 3 A
Voltage: 125, 250, 30 V
... has sub-miniature air switches. These one of a kind switches use a standard sub-miniature single pole double throw electrical switch certified UL and CSA. These highly flexible and reliable switches ...
... The Bulldog alignment and rip detection switch is an electro-mechanical system designed to detect dangerous misalignment of the conveyor and also detection of belt tear damage. The switch will detect horizontal misalignment ...
Operating temperature: -20 °C - 55 °C
... The 4B Pull switch is also called as a conveyor safety stop switch which makes it optimal for stopping conveyors. This device is equipped with a double ended pull mechanism has slack or taut wire operation. ...
Primary current: 400 mA
Voltage: 24 V
... hole required in the pane. As door opening buttons CHT51 switches are suitable for the high frequency continuous service used in the passenger transport and building technology. The switches provide ...
CAPTRON
Primary current: 400 mA
Voltage: 24, 12 V
... Description The SENSORswitch CHT6 is designed for adhesive mounting on single glass and switch by touch. The SENSORswitch CHT6 can be switched one sided through single glass. For installation / application it is not required to have ...
CAPTRON
Primary current: 400 mA
Voltage: 24 V
... Description The SENSORswitch CHT61 is designed for adhesive mounting on glass and switch by touch. The SENSORswitch CHT61 can be switched one sided through double glass. For installation / application it is not required to have a hole ...
CAPTRON
... The Safemaster STS engineered by Dold, is a safety interlock switch that features a complete safety concept. This device offers users a standard expandable system and is composed of a durable stainless ...
Primary current: 0 A - 0.5 A
Voltage: 0 V - 100 V
Diameter / length: 14.5 mm
... MCS-100 is an alarm and security switch characterized as either normally open or closed switch. It allows various switching distance with a 10VA maximum switching capacity. This switch ...
Primary current: 0 A - 0.5 A
Voltage: 0 V - 100 V
Diameter / length: 47.5 mm
... MCS-114 is an alarm and security switch characterized as either normally open or closed switch. It allows a 6mm switching distance with a 10VA maximum switching capacity. This switch ...
This product features a 30.5 mm cut out panel and is able to travel a distance of 6 mm. Adding to this, it offers IP66/IP69K lkevel of protection and houses a fairly big touch surface. The user is able to choose between various types of push buttons , ...
Primary current: 5, 15 A
Voltage: 250, 30, 125 V
Operating temperature: -20 °C - 60 °C
... SRT Conveyer Belt Misalignment Switch use various electromechanical and electronic technology to protect equipment and personnel. These safety devices include: – SRT belt misalignment switch – SRS safety ...
Primary current: 15, 5 A
Voltage: 30, 250, 125 V
Operating temperature: -20 °C - 60 °C
... SRS Safety Cable Pull Switch use various electromechanical and electronic technology to protect equipment and personnel. These safety devices include: – SRT belt misalignment switch – ...
Primary current: 2 mA
Voltage: 3 V
... include: output- switch, latch, etc., high temperature resistance, package design and much more. Also available in a micro-power version that operate on 2.5-3.5 V battery voltage with only 5μA average supply current vs. the industry ...
Primary current: 4 mA
Voltage: 24 V
... options include: output- switch, latch, etc., high temperature resistance, package design and much more. Also available in a micro-power version that operate on 2.5-3.5V battery voltage with only 5μA average supply current vs. the industry ...
Primary current: 8, 16, 5 A
Voltage: 380, 250 V
... gas-insulated switchgear, and other high-voltage systems. The XCSK Series Magnetic Blowout Micro Switch is a high-reliability, industrial-grade switch known for its superior mechanical strength and durability. Housed ...
Width: 17.5 mm
Height: 114.5 mm
... Shield-EN series non-contact safety switch is specially designed and developed for compact application, it can be used to monitor various safety doors, safety windows and motion safety ...
Bytorent Technology Co., Ltd.
Width: 117.5 mm
Height: 114.5 mm
... Shield-EN series non-contact safety switch is specially designed and developed for compact application, it can be used to monitor various safety doors, safety windows and motion safety ...
Bytorent Technology Co., Ltd.
Diameter / length: 30 mm
Width: 15.5 mm
Height: 50 mm
... Shield-EN series non-contact safety switch is specially designed and developed for compact application, it can be used to monitor various safety doors, safety windows and motion safety ...
Bytorent Technology Co., Ltd.
Primary current: 400 A - 800 A
Voltage: 240 V - 500 V
... VSS3P0800 The Kutai VSS (Voltage Selector Switch) is unique and easy to operate. By rotating the handle, the operator can change any 10 or 12 lead generator from Hi Y-Y Rated Current 400 Amps to Low Y-YY Rated Current 800 Amps in a few ...
Primary current: 200 A - 400 A
Voltage: 240 V - 500 V
... VSS3P0400 The Kutai VSS (Voltage Selector Switch) is unique and easy to operate. By rotating the handle, the operator can change any 10 or 12 lead generator from Hi Y-Y Rated Current 200 Amps to Low Y-YY Rated Current 400 Amps in a few ...
Voltage: 0.2 V - 1,000 V
... Our voltmeter selector switch meets all of your voltage measurement needs, whether you’re working on a sophisticated industrial system or handling DIY electrical chores. It can handle all voltages, from low to high, AC ...
Voltage: 12 V - 220 V
Operating temperature: -25 °C - 70 °C
... Our illuminated selector switches are made with the highest level of precision, ensuring long-lasting performance and suitability for a variety of industrial applications. Furthermore, KINRED illuminated selector ...
Primary current: 25 A - 150 A
Voltage: 400 V
... Many of our switches are available in enclosed form and suited to direct switching of motors. They have AC-3 breaking capacities as per EN 60947-3. In addition to the standard units, there are special switches, versions with a fuse block ...
Operating temperature: -25 °C - 75 °C
... Sensor type - Magnetic switches Connections - M8 4-pole connector Packaging dimensions HxLxW (mm) - 15 x 150 x 110 Product class - C Custom tariff - 9032890 Connection type - Connector ...
Primary current: 0.25, 6, 4 A
Voltage: 250, 24, 230 V
Operating temperature: -40 °C
... thermoplastic, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0 Actuator stainless steel 1.4301 Switch type type 2 Coding level low coding Degree of protection IP65 (IEC/EN 60529) B10d (10 % load) 2 ...
steute Schaltgeräte
Voltage: 10 V - 28 V
... Switch designs cover broad frequency bandwidths from DC to 46 GHz Power handling capability ranges from 10 watts to 275 watts Impressive performance which includes up to 80 dB Isolation and 15 ms Switching Speed Popular ...
Pasternack Enterprises, Inc.
... accurate pressure control is desired and necessary several pressure switch and control devices are available. For example the universal pressure switch PS 115, the low pressure safety switch ...
Voltage: 4 V
... Window contact for status monitoring of windows and doors. Energy generation by solar power. Battery-free transfer of the opening state of doors and windows. ...
Thermokon Sensortechnik
Primary current: 16 A
Voltage: 230 V - 400 V
... - Key operated power isolation or circuit control switch lock Standard sequence: key release when power «off» - Panel mounting (BOB), at option choice wall-mounted (FOB) - 1 to 5 locks (keys). Multiple lock ref: 2E, 3E, 4E, 5E ...
SECUMS Interlocks
... FG series safety switches with separate actuator with lock Protection degree: IP67 according to EN 60529 with cable gland having equal or higher protection degree. Working method: D working method, locked ...
Pizzato Elettrica
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.