- Electricity - Electronics >
- Switch and Relay >
- Technology switch
Technology switches
Primary current: 16 A
Voltage: 230 V
... Function: Control switches are suitable, amongst other things, for switching electrical consumers or generating static signals for controls. Control switches from series RSS have the capability to switch ...
Doepke Schaltgeräte GmbH
... >The T6 magnetically held toggle is an environmentally sealed, compact switch designed and qualified for aerospace flight-deck applications. The operator manually engages the switch; it remains held by an internal solenoid ...
OTTO
Primary current: 30, 268, 60, 215 mA
Voltage: 24 V
Diameter / length: 70, 92 mm
... with a safety relay unit (SS4 series) Models - SS2-P-110/120/130: Safety Output: Relay, N.O. Contact x 1, Auxiliary Output: N.C. x 1 - SS2-OX-110/120/130: Safety Output: Relay, N.O. Contact x 1, Auxiliary ...
Line Seiki
Voltage: 10 V - 30 V
... Series 1750 Solid State switches are available for use on most Tom Thumb and PHD products for simple interfacing to many types of electrical controllers. These switches are offered in 10-30 VDC current sinking and current ...
PHD, Inc.
... The SFN series safety non-contact door switches utilize magnetic type detection to monitor opening and closing of doors. The dedicated controller allows multiple connection of up to 30 units. The switches ...
Autonics
Primary current: max 16.0 A
Voltage: max 250.0 V
... manufactured by Arcoletric, is a safety cut out switch that has a rated current of 16 ampere and a rated voltage of up to 250 V AC. It incorporates an NC contact, shatter switches and lever slope operations. ...
Arcolectric
... WM-547 Rotary Hand Controls are designed for a variety of off-highway applications. It is infinitely variable between 0° and 90° with applicable uses that include engine RPM, chassis module inputs and hydraulic pump control. The Rotary Hand Control ...
Primary current: 1, 2 A
Voltage: 24, 230 V
Operating temperature: -25 °C - 80 °C
... IDEM’s magnetic, non-contact safety interlocks are designed to conform to IEC 60947-5-3 and be used as directed by ISO12100, ISO14121 and ISO EN14119. They feature magnet and reed technology, providing ...
Idem Safety Switches
Voltage: 24, 12 V
... which monitored function failed leading to the alarm or shutdown magnetic switches do not. Magnetic switches operate basically as a latching relay. Application Magnetic switches and Tattletale annunciators ...
Primary current: 5 A
Voltage: 250 V
... Mounting Mounting cut-out - Ø 22,3 mm Design - raised Front Front dimension - Ø 22 mm Other Attributes Weight - 0,080 kg Operating-/Indication part Lever colour - black Connection Method Terminal - Solder 2.8 x 0.5 mm Actuator Switching ...
EAO France
Primary current: 0.4 A
Voltage: 60 V
... range of ATEX sensors. celduc® relais has EC-type examination certificate Nr. INERIS 04ATEX0105. Groupe II : Open-air industry (other than mines) with possible inflammable dust. Type of devices : 1 for zone 0 (continuous risk) 2 ...
Primary current: 16 A
Voltage: 690 V
... e EN60069-2-27 Shocks resistance as EN600068-2-29 Connections: spring clamp contacts for push buttons, mushrooms, rotary switch screws terminals for cam-switches, buzzers and socket outlets Ambient temperature: operating -25° + 70°C, ...
Giovenzana International B.V.
Primary current: max 21.0 A
Voltage: max 250.0 V
... Versatile miniature snap switch High level of repeat accuracy & contact stability Switching current 0.1 to 21 A at 250 VAC Wide variety of auxiliary actuators and terminal options Housing material PA 6 (T85 versions, ...
CHERRY
Primary current: 100 mA
Voltage: 12 V
... RoHS compliant Excellent contact stability by twin Gold-plated contact mechanism Load life of 30,000 cycles Compatible with automatic mounting Withstands high soldering temperature ...
Nidec Copal Electronics
Primary current: 4 A - 20 A
Voltage: 12 V - 250 V
Operating temperature: -40 °C - 85 °C
... Carling’s V-Series Contura® sealed rocker switches are well known for their cutting edge design, high quality, maximum performance and unmatched reliability. These snap-in rocker switches offer countless options for ...
Carling Technologies
Primary current: 6, 10, 16 A
... Panel mounted selector switches offer a 7-position voltmeter switch and a 4-position ammeter switch for reading line-to-line or line-toneutral voltage and phase current. Each switch can ...
Primary current: 0.4 A
Voltage: 48 V
... PCB Mount Miniature Toggle SwitchesPCB Mount Miniature Toggles 0.4VA Logic Level Base of heat resistant resin meets UL94V-0 flammability rating. Max voltage capability of 48V allows use in medium source applications and increases operating life. ...
NKK Switches
... stop stations now give customers more choices than ever before. IDEC enclosures coupled with IDEC HW and XW emergency stop switches are a perfect match. Our E-stop stations offer a variety of contact configurations; 29, 40 or 60mm mushroom ...
IDEC
... On/off switch GS On/off switches according to utilisation category AC-23 (switching of motor loads or other highly inductive loads) according to DIN VDE 0660 Part 100. The regulations in DIN VDE 0113 Part 1 and EN 60204 ...
... prevented by a tab which retracts when not required - Insulating material ensures electrical safety - Design and shape help avoid build-up of dirt and make the switch easy to clean - ISO 13850 illuminated mushroom ...
BACO
Primary current: 16 A
... which are: switches for control, signalling and measuring circuits; switches, selector switches and step switches like for transformers and welding apparatuses; group switches like for ...
Primary current: 16 A - 40 A
... Rotary cam switch GX series, ON-OFF switch 3 poles 16A, for front mounting with red/yellow handle padlockable in 0 and protection covers, front plate 48X48mm •Type of product: ON/OFF switches •Switching ...
Primary current: 170 mA - 450 mA
Voltage: 24 V - 28 V
... Single pole, miniaturised aircraft simulator switch with extremely fast magnetic trip time. Blade, screw and wire wrap terminals. Aircraft style threadneck and push/pull button with white trip indicator ring. Current rating marked on ...
Voltage: 3 V
... Fit for sun-blinds and awnings. Frequency: 433.92 MHz. Range: Up to 200m (Open-field) ...
... Every electric switch onboard has to meet the highest demands. Mastervolt offers a wide choice of stylish, waterproof switches for a range of onboard functions. All fully waterproof switches (IP66) ...
... Flush Silhouette Switches LB Series Selector Switches Flush bezel projects only 2mm from front of panel Lever Operator (Photo: Left) 2-position and 3-position selector switches. Maintained and other various spring return ...
IDEC USA
Primary current: 0.13 A - 1 A
Voltage: 1 V - 24 V
Diameter / length: 22 mm
... areas •Zero power required for keypad operation •Mimics a dry contact switch closure •Eliminates RFI, EMI and ESD issues •Five year warranty • Switch Function – N.O. Momentary • Switch Voltage – 0-24 ...
Barantech
Primary current: 3, 5 A
Voltage: 28, 115 V
... environmentally sealed switches that are constructed for applications where high reliability and extreme environment temperature are demanded. This is suitable for commercial, military aircraft and space applications. These switches ...
Haydon Kerk Pittman
Primary current: 3, 0.5 A
Voltage: 125 V
... Double pole single throw switch Stainless steel face plate The Edwards 6537 pull cord switch provides emergency call activation. The call may be reset at the initiating switch. Cords are replaceable ...
EDWARDS SIGNALING
Primary current: 12 A
Voltage: 690 V
... Measuring 3-phase switches 48x48mm Ammetric switches, 3 currents Voltmetric switches, 3 linked voltages Voltmetric switches, 3 linked voltages + 3 phase voltages lt allows to use only one meter to measure, by scanning, the linked ...
Primary current: 0.25 A - 200 A
Voltage: 600 V
... loads, these solid state switches have accurate, very low fixed or user adjustable setpoints, which are activated when the desired amperage is reached. The adjustable CSSGA2100NN and CSSGA2100R1 units have LED’s, which indicate switch ...
Primary current: 0.25 A - 16 A
Voltage: 24 V - 690 V
... Protection degree: IP65 Operating temperature according to the reference standard: -25°C+70°C IK degree at 20°C: IK05 - IK09 Material: Engineering plastic EN 60947-5-1 Low-voltage switchgear and controlgear Part 5-1: control circuit devices and ...
Primary current: 10 A
Voltage: 30 V
The Camlock All Brass 7-Pin Octagon Radial Pin Tumbler S28 is utilizable for applications such as smooth key controlled switching is needed, having the extra advantage of being able to make part of a expanded keyed similar system by this product. It also ...
Camlock Systems
... A big 'Rotate to Set' special needs switch featuring a unique patented variable pressure mechanism with diameter 127mm. Simply rotate the coloured top to increase or decrease the actuation force required. Use on a tabletop or mount on ...
Voltage: 65 V
... BOP Max. (G):110 BOP Min. (G):10 BRP Max. (G):-10 BRP Min. (G):-110 Description:BIPOLAR HIGH VOLTAGE HALL EFFECT LATCH Output Current (mA):25 Package:TO-92S Status:Active Supply Current Typ. (mA):3 Supply Voltage (VCC) Max. (V):30 Supply Voltage ...
Primary current: 100 A - 200 A
Voltage: 20 mV - 40 mV
... G&H Technology switches provide extremely high reliability, one-time actuation and can be used to permanently open or close single or multiple electrical circuits. Applications include terminating an event or sequence ...
Cooper Interconnect
Voltage: 2.7 V - 24 V
... latch range: ±0.4mT to ±80mT Wide magnetic switch range: ±1.5mT to ±66mT Programmable hysteresis: 1mT to 36mT Product description Melexis’ Latch & Switch sensor ICs use an innovative magnetic technology ...
Melexis
Voltage: 90 V - 250 V
... A 2U (3.5 high), reconfigurable Microwave Switching chassis which comes with a LAN or IEEE-488 interface. RF Relays configurable in a wide assortment of relay form factors, 1x2 to 1x12 with or without internal terminations Reliability 10 Million operations Repeatability ...
Giga-tronics Incorporated
Primary current: 0.3 A
Voltage: 24 V
Operating temperature: -10 °C - 55 °C
... 7mm ON / 20mm OFF The MAGNASAFE MS5 are compact, non-contact safety switches designed for use with modern safety relays. Encapsulated into red ABS housings, the MS5 safety switches ...
Mechan Controls
Primary current: 0.2 A
Voltage: 24 V - 250 V
... Compact Housing Wide 10mm sensing LED indication Up to PLe/Cat.4 with ZANDER safety relay High tolerance to misalignment 2 NC/1NO transistor circuits Protection category IP67 ...
Zander GmbH & Co. KG, Hermann
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.