Primary current: 3 A
Voltage: 230, 24 V
Diameter / length: 32.7 mm
... • Metal enclosure • Design to EN 50047 • Actuator heads can be repositioned in steps 4 x 90° • Different contact options • Latching force 12N or 30N depending on variant ...
SCHMERSAL
Primary current: 3 A
Voltage: 24, 230 V
Diameter / length: 32.7 mm
... • thermoplastic enclosure with foldable latching cover • Design to EN 50047 • Actuator heads can be repositioned in steps 4 x 90° • Different contact options • Latching force 12N or 30N depending on variant ...
SCHMERSAL
Primary current: 10 A
Voltage: 6 kV
Diameter / length: 30 mm
... Thermoplastic enclosure
Double-insulated
Long life
Universal coding
Large wiring compartment
High level of contact reliability with low voltages and currents
Slotted holes for adjustment, circular holes for location
Insensitive ...
SCHMERSAL
Primary current: 4 A
Voltage: 12 V - 30 V
... In-line switches, motion detectors and PWM controllers with M12 connectors Switch options with rugged metal housings Perfect for dc-powered task lights, indicators, or tower lights 3-wire dimmers are compatible with PWM models of many ...
BANNER ENGINEERING CORP.
... Available spans range from 6 to 100 m Trip and latch switch models are available Minimum switch life is 1 million operations Heavy-duty switch housings withstand harsh environments ...
BANNER ENGINEERING CORP.
... risk of intentional defeat Magnets with different polarizations add security For safety applications, switch must be used with Banner safety controllers or GM-FA-10J safety ...
BANNER ENGINEERING CORP.
... Interface RF Connectors with Switch, 3.9mm Height, DC to 6GHz Interface RF Connector with Switch, 3.9mm High, DC to 6GHz 1. Low insertion loss Typically, 0.08dB at 1GHz Typically, 0.1dB at 2GHz 2. Space saving ...
Voltage: 230 V
... The mechanical safety switches PSENmech are suitable for safe monitoring of a movable guard. If guards are opened, the safety switches PSENmech are tripped. The hazardous machine movement ...
PILZ
Primary current: 10 A
Voltage: 240 V
Operating temperature: -30 °C - 80 °C
... Mechanical safety switch, with radius actuator, contacts: 1 N/O, 1 N/C. Technical data Utilisation cat. AC15/DC13sta. - EN 60947-5-1 Environmental data Protection type, housing - Mechanical data Connection ...
PILZ
Primary current: 10 A
Voltage: 240 V
Operating temperature: -30 °C - 80 °C
... Mechanical safety switch, with radius actuator, contacts: 2 N/C. Technical data Relay outputs Utilisation cat. AC/DC1 stand. - EN 60947-4-1 Utilisation cat. AC15/DC13sta. - EN 60947-5-1 Environmental data Protection ...
PILZ
Voltage: 15 V
Diameter / length: 6 mm
Operating temperature: -25 °C - 85 °C
... Encoder with integrated PCB (with and without debouncing function) and various mechanical interface options Product Features Swiching torque up to 4.5 Ncm Various options and customizations available Various mechanical interface options ...
Elma Electronic AG
Primary current: 10 mA
Voltage: 15 V
Diameter / length: 6 mm
... Coded switch with two shafts, HEX or Gray coding with up to 16 positions on outer and 2 or 3 positions on inner shaft Product Features 22.5° indexing angle (36° indexing angle on request) Various options and customizations ...
Elma Electronic AG
Primary current: 200 mA
Voltage: 42 V
Diameter / length: 1.8, 3 mm
... Coded switch with push function, HEX or Gray coding, push force up to 14 N and up to 3.5 Ncm switching torque Product Features 22.5° or 36° indexing angle Various options and customizations available HEX or Gray coding ...
Elma Electronic AG
Primary current: 10 A
Voltage: 240, 250 V
... BERNSTEIN introduces their Rope Pull switches Series. These strong, double-spanned cable pull switches are primarily used in emergency stop applications. Since every top industries have a fail-safe plan to ensure the ...
Operating temperature: -30 °C - 75 °C
... Safety Rope Pull Switch SRO When it comes to maximum safety on the assembly line, in the production line, or directly at the machine, the Safety Rope Pull Switches ...
... Standard Rope Pull Switches Because of their specifications governed by corresponding standards, these cable pull switches are used exclusively as safety command devices. These switches ...
... Cable Pull Switches can be installed along or around awkward machinery such as conveyors and provide a constant emergency stop access. The system includes a rope status indicator and emergency stop button mounted on the switch ...
Allen-Bradley
Voltage: 0.1 V - 48 V
Operating temperature: -25 °C - 70 °C
Width: 10, 12.5, 8, 7.6 mm
... integration: integration solutions, calculation, safety assessment, cost control, and proven dependable quality. Extensive research at Crouzet has resulted in industrialized and manufactured buttons (one pole, two ...
Voltage: 110 V - 230 V
... Product description
Connected 2-way
switch for local or remote control of lighting. Installation and wiring follow the same scheme as a traditional 2-way
switch. Compatible with loads up to 250 W. Equipped with ...
BTICINO
Primary current: 5, 3 A
Voltage: 250, 30, 125 V
... Separate Construction with Cylindrical 16-dia. Body • Same separate construction as the A16-series Pushbuttons with Miniature Design of 28.5 mm • The same contacts can be used for both standard loads and microloads. • Oil-resistant IP65 models • ...
OMRON
... million cycles in contactors — maintenance‑free across the whole lifecycle. For utilities, OEMs and industrial operators who demand uptime, safety and long-term economy, Siemens vacuum interrupters deliver proven German ...
... switching operations Switching devices can serve to switch lighting systems, motors, and other electrical devices on and off. Switching devices designed for manual operations enable users to switch electrical loads ...
Siemens Low-voltage – Power distribution
Primary current: 0.2 A - 16 A
Voltage: 800 V
... Our ACST series are over-voltage protected triacs that protect themselves by folding back and leading current into the load when subjected to an overvoltage. This feature and the well-dimensioned 10 to 35 mA gate versions as well as its 800 V, 4 to 16 ...
Primary current: 0.5 A - 10 A
Voltage: 110, 230, 240 V
... The snap-action switch S926 is a version with an identical design to the S826 snap-action switch with a polyetherimide (PEI) housing. The dimensions, the switch mechanism and the electrical properties ...
Schaltbau GmbH
Voltage: 6 V - 28 V
Operating temperature: -40 °C - 150 °C
... Automotive 2ch 45 mΩ High-Side Switch with Variable OCD and OCD Mask Function BV2HD045EFU-C is a 2-ch high-side switch for automotive application. It has built-in over current protection function, thermal shutdown protection ...
ROHM Semiconductor
Primary current: 10, 16, 22, 6 A
Voltage: 250, 125 V
Operating temperature: 0 °C - 85 °C
... wide circuit in standard or custom colors for illuminated and non-illuminated versions. Custom legends are available on the switch lever and bezel. The 1600H/2600H High Inrush option is designed to handle high inrush currents up to 100A ...
Eaton Commercial Controls
... The smart light switch combines the reliability of professional security systems and a thoughtful user experience. The entire panel is sensitive to touch and even the hand approaching (at a distance of 15 mm). LightSwitch ...
AJAX
... Failsafe /Latching, SPDT, 50Ω impedance Available in Commercial and Elite models, with 1.85mm connectors. DC-67GHz ...
Teledyne Relays
Primary current: 0.01 mA - 100 mA
Voltage: 0 V - 35 V
Diameter / length: 0.1 mm
... MICON 5 tactile switches offer extreme switching reliability, with a very small space requirement. They can be arranged individually, in rows or as key blocks. For use beneath overlays, we recommend combining the MICON 5 key switches ...
RAFI GmbH & Co. KG
Primary current: 10 A
Voltage: 250 V
Diameter / length: 24 mm
... 20mm Diameter Round Rocker Switches Black Mini Round Black White Red 3 Pin ON-OFF Rocker Switch KCD1 Current:10A, Voltage:250V T105 Approved: TUV ...
Yueqing Tongda Wire Electric Factory
Primary current: 48, 10, 4 A
Voltage: 125, 250 V
Diameter / length: 21.6 mm
Current:10A, 10(1.5)A, 4A/48A Voltage:AC 125V/250V T85, T125 Approved: UL,cUL(CSA),VDE,ENEC,CQC, TUV
Yueqing Tongda Wire Electric Factory
Primary current: 1 A - 3 A
Voltage: 250, 125 V
Diameter / length: 12.8 mm
... Micro Limit
Switch Momentary Push Button
Switch 0.1A/1A/3A 125V AC Mouse
Switch 3Pins Long Handle Roller Lever Arm SPDT 12* 6 *6.5mm
Current:0.1A/1A/3A
Voltage:125V/250V 40T125
Approved: ...
Yueqing Tongda Wire Electric Factory
Primary current: 16 A
Operating temperature: -20 °C - 55 °C
... - IIC Group - Zones 1, 2, 21, 22 - Category 2GD or M2 CSC instrument cabinets are normally used to contain analog needle instruments such as small ammeters and voltmeters. Temperature class - T6 Application / usage - ATEX zone ATEX zone - Zone ...
Voltage: 500, 250 V
Operating temperature: -40 °C - 60 °C
... encapsulated pressure resistant potentiometer - Continuous setting process parameters - Four screw terminals with two clamping points each in increased security (ex e) - Large clamping range for rigid or flexible conductors - ...
Primary current: 12 A
Voltage: 690 V
Diameter / length: 48 mm
... 48x48 current & voltage selector switches • insulation voltage 690V • impulse withstand voltage 4kV • storage temperature -30 +70 °C • screw terminals M3.5 2x2,5mm² • control protection degree IP65 • terminals ...
Primary current: 12 A
Voltage: 690 V
Diameter / length: 57 mm
... Voltage Selector Switch - 4 positions, 3 DIN modules Voltage Selector Switch - 7 positions, 3 DIN modules Current Selector Switch - 4 positions, 3 DIN modules • insulation voltage 690V • impulse ...
Diameter / length: 1 mm - 3 mm
Operating temperature: -25 °C - 70 °C
... door holding • Contactless coded electronic sensor • Total safety management with an AWAX controller • Level of performance with AWAX controller: up to PL = e • Safety category: up to 4 with an AWAX ...
COMITRONIC - BTI
Voltage: 24 V
Operating temperature: -40 °C - 125 °C
... Stainless steel non-contact safety Switch 316L Position control for doors / casings on hazardous machinery Contactless coded electronic sensor Total safety management with an AWAX controller High ...
COMITRONIC - BTI
Operating temperature: -40 °C - 125 °C
... • Safety category: up to 4 with an AWAX controller • Time before dangerous failure: MTTFd = 100 years • Max. activation distance: 3 mm, 1 mm hysteresis • Holding Force: transmitter + receiver in contact = 20N ...
COMITRONIC - BTI
Diameter / length: 22 mm
... Position selector: 2 positions 2-position rotary switch to manage left / right or front / back. ...
Primary current: 3 A
Voltage: 30, 125, 250 V
... Clippard MAS series switches (air to electric switches) use a standard miniature single pole double throw (SPDT) electrical switch which is UL, SEMKO, VDE and CSA certified. The range ...
Primary current: 5, 3 A
Voltage: 125, 250, 30 V
... has sub-miniature air switches. These one of a kind switches use a standard sub-miniature single pole double throw electrical switch certified UL and CSA. These highly flexible and reliable ...
Operating temperature: -20 °C - 55 °C
... The 4B Pull switch is also called as a conveyor safety stop switch which makes it optimal for stopping conveyors. This device is equipped with a double ended pull mechanism has slack or taut wire operation. ...
Primary current: 7, 9 mA
Operating temperature: -40 °C - 85 °C
... Sensata's SR3 Switch Rockers have been developed to provide the reliability required in demanding environmental conditions such as multifunction grips, dashboards or armrest controls for heavy duty industrial applications. ...
Diameter / length: 43, 58.9 mm
Operating temperature: -40 °C - 85 °C
Width: 40.7, 43 mm
... module is standard rocker switch with a single switch function in both directions. RS2 - With the RS2 a double switch function is available in both directions. QS1 - This ...
Primary current: 0 A - 0.5 A
Voltage: 0 V - 100 V
Diameter / length: 14.5 mm
... MCS-100 is an alarm and security switch characterized as either normally open or closed switch. It allows various switching distance with a 10VA maximum switching capacity. This switch ...
Primary current: 0 A - 0.5 A
Voltage: 0 V - 100 V
Diameter / length: 47.5 mm
... MCS-114 is an alarm and security switch characterized as either normally open or closed switch. It allows a 6mm switching distance with a 10VA maximum switching capacity. This switch ...
Voltage: 250 V
Operating temperature: -25 °C - 70 °C
... Selector switch, momentary Operating temperature -25 ... 70°C Switching position -45° idle position 45° momentary Contact type 1NO Approvals DNV, VDE , CCC , cURus , ENEC10 , CE , UKCA Switching function Momentary ...
Georg Schlegel GmbH & Co. KG
... • Operating Temperature : -25 ... 70°C • Storage Temperature : -40 ... 80°C • Mounting Aperture : Ø 30,5mm • Class of Protection : II (protective insulation) • Switching Function : Latching function • Approbations : cULus , CCC , CE , UKCA • Operating ...
Georg Schlegel GmbH & Co. KG
... Toggle head Protection class II (protective insulation) Switching function Maintained function Mounting aperture 26 x 26mm Shape square Front bezel colour anthracite ...
Georg Schlegel GmbH & Co. KG
Voltage: 24, 72, 110 V
Operating temperature: -40 °C - 70 °C
... The S51 lever switch series, specially developed for the rail sector, offers a high degree of robustness as well as a long service life. Typically, this high-quality product is found in driver’s cab consoles of rail traction units. All ...
Primary current: 1 A - 10 A
Voltage: 50, 125, 30, 250 V
Operating temperature: -40 °C - 85 °C
... frequency, low currents and voltages. Gold coated contacts can be supplied (approx 0,2μ), less than 42 Volt required. The screw connection M3.5 at the side is suitable for 2 conductors max. 2,5 mm². The plug-in connection at the top ...
Primary current: 5, 15 A
Voltage: 250, 30, 125 V
Operating temperature: -20 °C - 60 °C
... SRT Conveyer Belt Misalignment Switch use various electromechanical and electronic technology to protect equipment and personnel. These safety devices include: – SRT belt misalignment switch – SRS safety ...
Primary current: 15, 5 A
Voltage: 30, 250, 125 V
Operating temperature: -20 °C - 60 °C
... SRS Safety Cable Pull Switch use various electromechanical and electronic technology to protect equipment and personnel. These safety devices include: – SRT belt misalignment switch – SRS safety ...
Primary current: 15, 5 A
Voltage: 30, 25, 250 V
Operating temperature: -20 °C - 60 °C
... Belt conveyor safety cable pull switches are designed for providing a switching system to isolate the power to conveyor system and other equivalent process equipment in the emergency Condition. The cable pull switches ...
Voltage: 24 V
... possible • Communication functions in combination with an IO-Link Gateway GWY-CB or ESM-CB • Short circuit monitoring • 2 safety outputs (semiconductor outputs) • Open-circuit current principle • Category 4 / PL e according to EN ...
EUCHNER GmbH + Co. KG
Primary current: 1 mA - 100 mA
Voltage: 5 V - 24 V
Operating temperature: -20 °C - 55 °C
... • Up to 20 switches in series • Short circuit monitoring • 2 safety outputs (semiconductor outputs) • Up to category 4 / PL e according to EN ISO 13849-1 • With 2 plug connectors M12 • Multicode • Door monitoring ...
EUCHNER GmbH + Co. KG
Primary current: 50, 40 mA
Voltage: 26.5 V - 31.6 V
Operating temperature: -20 °C - 55 °C
... monitoring Evaluation is performed via a safety monitor. AS-Interface outputs D0 Guard locking LED function display The ASI LED indicates the state of the ASi bus. The STATE LED indicates the state of the switch. The ...
EUCHNER GmbH + Co. KG
Primary current: 2 mA
Voltage: 3 V
... MH04 series Hall Effect Sensor are packaged in a screw fastened flange mount rectangular housing with cable terminals. MH04 hall sensor custom options include: output- switch, latch, etc., high temperature resistance, ...
Primary current: 4 mA
Voltage: 24 V
... MH21 series Hall Effect Sensor are packaged in a screw fastened flange mount rectangular housing with cable terminals. MH21 hall sensor custom options include: output- switch, latch, etc., high temperature resistance, ...
Primary current: 20 A
Voltage: 150 V
... Les versions standard sont équipées : • d’un canon H=11mm • d’un levier Inox H=17mm • de cosses Faston 6,3mm D’autres options sont disponibles sur demande via notre lien RFQ • de 1 à 3 positions momentanées ou maintenues • cosses à souder, à visser ...
TactHill by Kynoppe
Primary current: 16 A
Voltage: 250 V
Operating temperature: -40 °C - 125 °C
... The 90 Series Toggle Power Switches are designed for applications requiring high reliability and resistance to extreme conditions. Available in 1 to 4 pole configurations, these switches offer IP68 sealing ...
TactHill by Kynoppe
Primary current: 16, 20 A
Voltage: 24, 250 V
Operating temperature: -25 °C - 85 °C
... Interrupteur professionnel pour demanding environments (industries, vehicles tout-terrain, etc.). Robust, waterproof (IP67), with luminous options and great variety of configurations. ⚙️ Technical features Pouvoir de coupure: - 16A at 125/250VAC - 20A ...
TactHill by Kynoppe
Voltage: 12 V - 220 V
Operating temperature: -25 °C - 70 °C
... Our illuminated selector switches are made with the highest level of precision, ensuring long-lasting performance and suitability for a variety of industrial applications. Furthermore, KINRED illuminated selector ...
Diameter / length: 22 mm
... Product Range: The RL-35XP switch series is available in the following variants: - Single- pole or double- pole contact - Switch function, 2 or 3-position changeover - ...
Lettel
Width: 19 mm
Height: 13 mm
... Product Range: The RL-33 switch series is available in the following variants: - Single- pole contact - Maintained switch function - Breaking capacity 6A or 10A - Customizable body and ...
Lettel
Width: 30 mm
Height: 22 mm
Lettel
Primary current: 16 A
Voltage: 230 V
... Function: WiFi switch control module
Applications
- Control of lighting circuits and loads within the rated current
- Use in commercial and
Primary current: 3 A - 50 A
Voltage: max 250.0 V
... Switch BC5 Series Supplementary Protector can be used in electric system which rated current from 3A to 50A, 50/60Hz, voltage AC 250V and DC65V to protect the overload and short of circuit. It is largely used in industrial ...
Primary current: 3 A - 25 A
Voltage: 250 V
... current from 3A to 50A, 50/60Hz, voltage AC 250V and DC65V to protect the overload and short of circuit. It is largely used in industrial automation equipment, telecommunication equipment, communication power , UPS and so on. Maximum ...
Primary current: 25, 15 A
Voltage: 250 V
Operating temperature: -25 °C - 80 °C
... installation along with excellent electrical performance and mechanical durability. The XT Series includes single- pole, double- pole, triple- pole, and four- pole options, ...
Primary current: 8, 16, 5 A
Voltage: 380, 250 V
... gas-insulated switchgear, and other high-voltage systems. The XCSK Series Magnetic Blowout Micro Switch is a high-reliability, industrial-grade switch known for its superior mechanical strength and durability. Housed ...
... to the guard locking solenoid Features Operating temperature (°C) - - 20 ... 55 Sensor type - Mechanical / electrical safety interlock Min. switching current at 24 VDC (mA) - 1 Packaging dimensions HxLxW (mm) - 90 x 110 x 115 Product ...