- Building - Construction >
- Industrial Building Equipment >
- Other air conditioning equipment
Other air conditioning equipment
... The task of industrial ventilation and air conditioning: Providing a comfortable air temperature for long-term presence of people in the room. In order to balance the conditions of the technological process and hygienic standards, industrial ...
... General Kinematics Vibratory Fluid Bed Sand Coolers are specially designed for evaporative cooling or drying of foundry sand. Air distribution decks are engineered to provide complete control of airflow for exceptional drying or cooling efficiency. OPTIONS: • ...
General Kinematics
... Pressurisation equipment for evacuation routes, designed according to the European standard EN 12101-6 Fire evacutaion route pressurisation systems designed in accordance with the European standard EN 12101-6. The KIT BOXPDS automatically regulates ...
SODECA
Cooling power: 300 W - 4,000 W
Heating power: 300, 500, 800, 1,000, 1,600 W
... Feature Flexible and convenient installation Low noise, efficient, corrosion resistant and outstanding high temperature performance The world famous compressor and fan Multifunction alarm output, real-time system monitoring, convenient human-computer ...
... Exhaust air systems and ventilation systems made of plastic, integrated into the overall exhaust air technology and ventilation construction If corrosive exhaust air and gases cannot be excluded in the ventilation system, plastic components are used ...
It is a technological device developed to absorb the expansion occurring in heating and cooling systems and keep the plant pressure constant. The device removes the pressure increases during plant water heating by accumulating the expanded amount of water ...
Tanpera
... Pressurizer is one of the most important equipment in nuclear power plant. The manufacturing technologies including CPR1000、AP1000 and CAP1000 by the Shanghai electric nuclear power equipment Co., Ltd. The manufacturing technologies including CPR1000、AP1000 ...
Power: 800 W
... Rack equipped with a door cooled by water, allowing you to host up to 45 kW of equipment without heating the air on output, and without disrupting the ventilation of the servers. The heated air coming from the servers is cooled by a coil of iced water ...
... Gentle and consistent product cooling The Thomas L. Green Forced Air Ambient Cooling Conveyor significantly reduces the internal heat of products immediately after they exit the baking chamber. Our cutting-edge equipment optimizes output and efficiency ...
... Tool for pressurizing and checking the hydraulic suspension system spheres. • - Developed in collaboration with the Car Maker’s repair methods. • - Customized design and manufacture according to a specification. ...
Maximum temperature: 6 °C
... For modern and efficient production processes At a glance: microprocessor-controlled cooling conditions ready to plug in delivery ex works - fst installation on the spot 1-truck to 6-truck units microprocessor control K-Touch 4012 available in many ...
Maximum temperature: -20 °C - 50 °C
Pressure: 5.5 bar - 12 bar
... Tool for the rapid filling of the radiator and the cooling system of cars and trucks. The system is vacuum-operated and allows for the cooling system to be filled quickly and completely, without having to start the vehicle several times during the operation. ...
The ITW GSE 3400 PCA is innovative, reliable and environmentally friendly. It supplies fresh, clean air into parked aircraft at carefully monitored temperatures and provides a pleasant atmosphere for the crew and the passengers. It also makes the aircraft ...
Power: 13 kW
Power: 2.75 kW
... Quick Details Condition: New Place of Origin: Guangdong, China (Mainland) Brand Name: Shantou Huaxing Model Number: LQ Application: shrimp chips/ round chips Voltage: 380V/50HZ Power(W): 2.75 KW Weight: 1700KG Dimension : ...
... Stainless Steel QTYHSeries High Pressure Air Treatment Units Stainless Steel QTYH Series High Pressure Air Treatment Units is suitable for all kinds of severe conditions, such as humid environment, high moisture content, high ambient temperature, etc... The ...
Flow rate: 10 l/min - 300 l/min
Air /oil coolers with blower or suction vent; air flow from 140 to 6,000 cm/H; oil flow 10-300 l/min; heat dissipable power from 1,000 to 30,000 Kcal/H; electric supply 12-24 VDC or 230-400 VAC at 50/60 Hz; optional termostat, pressure switch, hydraulic ...
FLUIDEA
An operating theatre is provided with preconditioned air by a central air handling unit (AHU). Nowadays, most hospital ventilation systems operate with a mixture of fresh and recirculation air. For operating theatres or minor surgery rooms to be upgraded ...
MANN+HUMMEL Air Filtration
... DATA SHEET Construction Pressurized system with integrated pressure control. Easy to install and Compact plug and play booster set. Brand new asynchronous single-phase motor. Equipped with pressure transducer, non-return valve, controlled starting current ...
Maximum temperature: 120 °C - 170 °C
Flow rate: 66 m³/h - 4,500 m³/h
Pressure: 15 bar
Air cooled aftercoolers series ACA are designed to reduce compressed air temperature and water vapour dew point in compressed air system. High efficiency axial fan forces ambient air over the heat exchangers copper tubes supported by aluminium fins, which ...
Atmospheric air is polluted with gases, vapour, particles of various chemical compounds but also with dust of various shapes, structure and density usually swirling in the air. The composition and concentration of pollutants in the atmospheric air depends ...
... GRAIN VENTILATION SYSTEMS The main objectives of ventilating a mass of cereal stored in a silo are cooling the cereal and maintaining its temperature in order to keep it in perfect condition and prevent the proliferation of insects and aerobic moulds. In ...
... Counterflow pellet coolers Ottevanger coolers are used for cooling pellets and extrudates to near ambient temperature. The coolers are available in 8 sizes with capacities up to 30 tph. Working principle Counterflow cooling is the most efficient ...
... Delphi charge air coolers are specifically designed to keep a car's powertrain running at optimal temperatures. And that means satisfied customers who are sure to keep their cool. - Product portfolio covers wide range of applications - Compact, ...
... VS-12 Explosive and Toxic Gas Ventilation System The VS-12 explosive and toxic gas ventilation system is a 850 CFM forced fan system used in battery charging rooms and other locations where motive power and stationary batteries are present. The VS-12 ...
Eagle Eye Power Solutions
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group