- Electricity - Electronics >
- Cable, Connector, Enclosure >
- 4-pole connector
4-pole connectors
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 4, 2 A
Voltage: 30, 90, 60, 250 V
... These M12 connectors can use 3, 4 or 5 contacts and are made with halogen-free units and black bodies. These are available in many colors and are used with locking screws and wire gauges to make it work carefully. The ...
Primary current: 300 A
Voltage: 3,600 V
... Smiths Interconnect announces today the release of the next generation of its modular Transformer Connector Range – Heavy Power Series, for on-board power applications within the rail market. The Transformer Heavy Power Series employs ...
Primary current: 7.5 A
Voltage: 300 V
... low-profile building-block connector family. GFPL series connectors offer right angle solder termination option. - High Reliability - Size 20 fixed contacts, 7.5 amperes - Low Profile, countersink side mounting holes. - ...
Primary current: 160, 200, 300 A
... Modular system configuration UL approval (single and 4- pole pole modules) APPLICATIONS Connectors for plug-in systems Connectors for machinery and ...
Stäubli Electrical Connectors AG
Primary current: 16 A
Voltage: 400, 250 V
... this installation connector can also be used in extremely confined spaces. The RST® MINI is a complete installation system comprising connectors, device connectors, cable assemblies, and distributors. COMPACT ...
WIELAND ELECTRIC
Primary current: 16, 50 A
Voltage: 25, 60, 400 V
... Series GA industrial connectors are high-quality special purpose connectors. The 15 pole circular connector has a housing made of high strength aluminium magnesium alloy. The contact ...
Primary current: 4 A
Voltage: 50, 300, 600 V
... B23 Gender connector housing A-side - Female Gender connector housing B-side - Male Style B-side - axial Gender power contacts A-side - Power= Female / Ethernet= Male Gender mating face B-side - Power= Male / Ethernet= ...
... ・PC board jack M12 ・rear mounting ・ 4- pole, A-coded according to IEC 61076-2-101 ・THR solderable ・Top entry ・Contact carriers black ・IP67 when plugged in ・suitable for applications in the railway industry according ...
METZ CONNECT
... ・PC board insert M12 ・ 4- pole, A-coded according to IEC 61076-2-101 ・THR solderable ・Top entry ・Contact carriers black ・suitable for applications in the railway industry according to data sheet ...
METZ CONNECT
... ・PC board jack M12 ・Cat.5 ・ 4- pole, D-coded according to IEC 61076-02-101 ・for 100 MBit Fast Ethernet (IEEE 802.3an) ・THR solderable ・Top entry ・Contact carriers green ・IP67 when plugged in ・suitable for applications ...
METZ CONNECT
Operating temperature: -25 °C - 85 °C
... Characteristics / technical specifications
- Model family: EEM 33-41/43
- Connector type: M12x1 coupling connector
- Number of pins: 4
- Plug housing material: PUR
- Cable
Novotechnik
Operating temperature: -40 °C - 85 °C
... Right-angled M12x1
4-pin unshielded
connector with factory‑attached cable for sensor and IO connections. Suitable for IO‑Link and analog mobile applications.
Key features
- M12x1, 4-pin,
Novotechnik
Operating temperature: -40 °C - 85 °C
... Product description
4-pin M12x1
connector, straight, unshielded, pre-wired with PUR cable. Suitable for IO-Link and analog mobile applications in industrial environments.
Technical specifications
Plug ...
Novotechnik
... illumination option – the diversity of possible contact equipments covers all options. There are connectors with 4 poles with SCHLEGEL pin assignment or with 5 poles with AIDA pin ...
Primary current: 12 A
Voltage: 600 V
Operating temperature: -40 °C - 125 °C
... Power moulded – coding S – cable connector Insert - Socket Material seals/o-rings - FKM (FPM) Material insulating body - PBT Material cable sheath - PUR Color contact insert - black Coding - S Number of poles ...
HUMMEL
Primary current: 12 A
Voltage: 600 V
Operating temperature: -40 °C - 125 °C
... moulded – coding S – coupler connector Insert - Pin Material seals/o-rings - FKM (FPM) Material insulating body - PBT Material cable sheath - PUR Color contact insert - black Coding - S Number of poles - 4 Pole ...
HUMMEL
Primary current: 12 A
Voltage: 600 V
Operating temperature: -40 °C - 125 °C
... coding S – right angle cable connector Insert - Socket Material seals/o-rings - FKM (FPM) Material insulating body - PBT Material cable sheath - PUR Color contact insert - black Coding - S Number of poles - 4 Pole ...
HUMMEL
Primary current: 2, 4 A
Voltage: 30, 300, 60 V
... Plug-in Connector straight with Cable available in different sizes Halogen, silicone and PVC free Suitable for drag chains (10xØ) ...
Primary current: 4, 2 A
Voltage: 60, 30, 300 V
... Plug-in Connector angled with Cable available in different sizes Halogen, silicone and PVC free Suitable for drag chains (10xØ) ...
Primary current: 4 A
Voltage: 60, 125, 32, 30 V
... Plug-in connector for flexible fabrication on-site Time-saving fabrication without stripping insulation from individual wires ...
Operating temperature: 200 °C
... Standard Range - Plugs/Male Standard Solid Pin Duplex Plug 200oC continuous use. ...
Temperature Technology Ltd
Operating temperature: 200 °C
... Our TTL connector range offers you a low-cost, high quality alternative: Single captive screw allows quick assembly ‘Slip-in’ designed lips allow for easy wiring Accepts stranded or solid wires Ergonomic design All connectors ...
Temperature Technology Ltd
Operating temperature: 200 °C
... Our TTL connector range offers you a low-cost, high quality alternative: Single captive screw allows quick assembly ‘Slip-in’ designed lips allow for easy wiring Accepts stranded or solid wires Ergonomic design All connectors ...
Temperature Technology Ltd
... constructions available
Panel mount connectors
- Designed for
... Product overview
FSX0CAH-P04MS-000 is a Push-Pull circular
connector assembly designed to provide a compact, reliable and high-performance interconnect solution for industrial automation, medical devices, instrumentation and ...
Primary current: 10, 16 A
Voltage: 250, 400 V
... Easy to rely on – ideally suited for ruggedized, moving applications where vibrations and dust are commonplace 2 to 5- pole versions plus PE Up to 16 A at 400 V IP54 protection class rating ...
HIRSCHMANN
Primary current: 350, 420, 320 A
Voltage: 1.1, 7.2 kV
Operating temperature: -40 °C - 80 °C
... Connection type: Screw Ring Pin Configuration: • 4- pole: 420A 1,1kV 185mm2, Internal fibre optic \ 350A 7,2kV 150mm2 • 5- pole: 320A 1,1kV 185mm2 Certification: EAC Keying position: 1, 2, 3, ...
Cavotec
Primary current: 7.5 A
Voltage: 250 V
Operating temperature: -40 °C - 90 °C
... Connectors in ET design from ESCHA are overmolded in a one-shot process. This means less susceptibility to errors as well as a faster, more reliable and more cost-effective wiring. Flexible, silicone- and halogen-free control line ...
Primary current: 1 A
Voltage: 30 V
Pitch: 2.54 mm
... These rugged US B connector solutions have USB 2.0 performance with overmolded Type A or B cordsets, cable plugs and panel mount receptacle options. When it comes to sealed industrial US B ...
Bulgin Components
... M8 FIELD ATTACHABLE,FEMALE,METAL HOUSING 180°, 4P.,SCREW CONTACTS Family: Straight 180° - 4 poles ...
H.T.P.
Primary current: 50 A
Voltage: 250 V
... The speakON cable connectors are the industry-standard connectors for amplifier / loudspeaker connections. The entire family of 2, 4 and 8 pole cable connectors has ...
Neutrik
Primary current: 160, 200 A
Voltage: 440 V
... ◇ Maximum current: 200A, maximum voltage: 440V ( 4 core). ◇ Housing is made of cast aluminum; sealing is made of chloroprene rubber; fasteners are made of stainless steel. ◇ Monolithic insulators are made of nylon PA6. Insulators for ...
JIANGSU JIANLONG ELECTRICAL CO.,LTD
Voltage: 450 V
Operating temperature: -40 °C - 105 °C
... Mini push-in wire connector in white color with 2 poles for stranded (single core) cables. The mini push-in wire connector facilitates the connection of 2 stranded (single core) cables, in junction boxes ...
SAS
Primary current: 10 A
Voltage: 250 V
Operating temperature: -55 °C - 70 °C
... 2, 21 and 22. The eXLink 4- pole/ 4+1 pole is a complete system for connecting and disconnecting products electrically. Supplying from low voltage BUS signals up to 250 V AC / 10 A electrical ...
Grupa Wolff
... Connector ( 4PIN DIN) mating part KPP- 4P Net weight - 0,003 kg Connector - 4PIN DIN ...
... M12 plug d code 4 pin field mountable male unshielded IP65/67 Area of application: Industry and outdoor use IP 65/67 Metrical field mountable unshielded M12 plug male with PG 9 cable gland straight Coding D Coded Housing ...
AIXONTEC
Primary current: 80 A
Voltage: 690, 415 V
... Insert -K Series , 4P+E, Screw termination, Male, Back Entry, 80A, 830 V, 8kV, Size:16B, Contacts: 4P, PBT, Connector Material: Brass (Silver Plated), Grey - RAL 7044 Cable Cross Section: ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group