... Level control relay for conductive liquids Type 72.51 with Adjustable sensitivity (5…150) kΩ and 6 functions. Delay time (0.5 s or 7 s) selectable. Technical features: • Emptying or filling functions (6 functions) • ...
... analysis
Series
Series 70
Applications
Suitable for grid/generation interface systems, continuity ...
Tripping current: 16 A
... The 72 Series comprises level control relays for conductive liquids. Features include (according to Type): • Sensitivity fixed or adjustable (5…150kΩ) • 35mm rail (EN 60715) mount ...
Tripping current: 5 A - 15 A
Trigger voltage: 24 V - 240 V
... This Harmony RM35-JA relay allows monitoring of current control in single phase networks. This modular multi function single phase current control relay is ideal for monitoring of electrical ...
Schneider Electric
... The SEL-352 relay provides breaker failure protection, breaker control, and breaker monitoring. Features include a cost-saving data recorder and a sophisticated controller to reduce maintenance and manual operations. ...
Schweitzer Engineering Laboratories
Tripping current: 0.1 A - 336 A
Trigger voltage: 690 V
... The UER1 thermal overload relays range up to an insulation voltage of 690V and an operational voltage of 690V, and can be driven by both 50Hz and 60Hz. They can provide current overload protection and phase loss protection, and the setting ...
... MC1 or MC3 type. The front of the relay has a control panel that is used to adjust the reactive current where the relay will act. It has a LED that indicates the status of the relay. The ...
Tripping current: 0.03 A - 3 A
... ELR-3B Earth Leakage Relays WITHOUT BUILT-IN Toroidal Transformer RELAY WITH ADJUSTABLE DELAY TIME AND SENSITIVITY Type B earth leakage relay. It is suitable for Direct current (DC), pulsating current, ...
FANOX ELECTRONIC
... This product is able to control the temperature of a motor room, as well as the temperature inside switchboards, which are defined by the lack of a motor room. The design in accordance to the EN 81-1 standard and compliance with the EU ...
FANOX ELECTRONIC
Trigger voltage: 230 V
... The ST/ST-D by Fanox are phase and temperature relays which serve as protection against phase imbalance, phase loss, phase sequence and over temperature. These are compatible with most motors that have a PTC sensor operation like elevators, ...
FANOX ELECTRONIC
Trigger voltage: 24, 48 V
... Product type Device for permanent control of the MCCB's tripping circuit or safety circuits Technical characteristics Control network voltage 13...30 VAC/DC (version TCS-1) 24...60 VAC/DC (version TCS-3) Power consumption ...
Trigger voltage: 110, 240 V
... RSR-72 type relay for re-start and reacceleration is deigned to perform the automatic motor restarting, after control and protection device opening, as a consequence of a momentary line voltage interruption or drop-out. The ...
... _1: - It is possible to set a variety of response parameters by means of a 4 bit selection facility from an overriding control unit; - Analog output (2 V to 10 V) corresponding to the current speed; - The possibility of overriding ...
... installations, such as switch-disconnectors, impulse relays (remote switches) and main switches. Impulse relays, also known as remote switches, are switching relays that switch on due to an electrical ...
Doepke Schaltgeräte GmbH
Tripping current: 3, 5 A
Trigger voltage: 154 V - 500 V
... • Monitors Phase Sequence,Phase Failure & Phase Asymmetry • 3P - 3W wiring configuration • Relay output: 1 C/O SPDT • Mounting : DIN-rail Brief Specifications Measuring Parameter : Phase Sequence, Phase Failure, Phase Asymmetry Electrical ...
Trigger voltage: 12 V - 240 V
... The Delay ON star/delta relay CRM-2T is mainly designed to provide an extremely high quality performance for any related applications the device will be used. The relay has the capability to control motor ...
ETI
Tripping current: 16 A
Trigger voltage: 230 V
... Relay that allows to extend the load of any telephone controller up to a 16 A load. • Operating temp. :0 ºC to +50 ºC • Degree of protection :IP 41 according to EN 60529 ...
ORBIS TECNOLOGÍA ELÉCTRICA
Trigger voltage: 24, 115, 230 V
... Brodersen's MXL-10 Level relay is a level relay to control one or two levels in a container, with conductive fluids. The relay can either control the pumps or the valves ...
Trigger voltage: 24 V
... conductivity level controls whose working is founded on measuring the resistance between two or more electrodes dip into fluids under control. Liquid between a reference electrode and one or more level electrodes causes ...
... The MS2P48 relay is a phase failure relay suitable for 3 phase supplies. The relay is designed to automatically change over from the primary supply to the secondary supply if any phase of the primary ...
... With growth in technologically sophisticated and energy efficient systems around the globe, Kuhse DC-solenoids provide the optimum alternative to enhance the energy efficiency of systems . In order to align magnets more efficiently ,electrical components ...
Tripping current: 16 A
... Impulse Current Breakers are used to control lightning from two or more points. Traditionally, the need for controlling lightning circuits in larger areas from various points was met by using vavien-key system. Limited number of keys, ...
Federal Elektrik
AQ 101D is a sophisticated micro-processor based arc flash protection unit for arc light detection. It is designed to minimize the damage caused by an arcing fault (arc flash) by tripping the circuit breaker sourcing the fault current. The AQ 101D complete ...
Arcteq Relays Ltd
... General Asymmetry adjustable phase protection relays are designed to protect the threephased motors that is threaten by failures that is originated from network voltages. ...
Tense Electronic
Trigger voltage: 12 V - 60 V
... For transfer, safety grounding, or tap selection at 12kV to 60kV peak test in air. Most HV contacts have full insulation above ground. A higher insulation level to ground is optional. Most units are spring return, can mount in any position, or may ...
Tripping current: 16 A
Trigger voltage: 230 V
... Sigma Impulse Leakage Relay is used to provide control from two ore more points of the illuminating illumination. The most important advantage of the Impulse Leakage Relay switch is that it provides as ...
SIGMA ELEKTRIK
... -Multi-function relay(RTU Built-in) for LBS and EFI (N1 for LBS, N2 for EFI) -Voltage, Current and Power Metering, Open Phase, Live Load Block, Synchronism Check, etc. -Fault detection and indication (FI) (Phase, Ground, Residual ...
ENTEC ELECTRIC & ELECTRONIC CO.,LTD
... electronic control with high capacity of special relays. Control voltages 12V UC. Contact position indicator with LED. Control power demand 0.2W only. Safe disconnection to VDE 0106, ...
Eltako Electronics
... RL10: Universal relay for filling or emptying RL11: Level relay for emptying RL12: Level relay for filling 1 or 2 sensor levels Adjustable sensitivity 1- or 2-pole relay output DC supply ...
... Electronic modular relay for automatic control of conductive liquids in a single tank. Adjustable sensitivity, either well or tank. Monitoring of filling (up) or emptying (down). - Plug-in base mounting (11 pin) - ...
GAVE ELECTRO
... The SSRC-04 is a liquid level controller relay. It is specially designed for the level and discharge control of conductive fluids placed in tanks, as seen in industrial plants and domestic tasks. The controller's main ...
Tripping current: 5 mA
Trigger voltage: 0 V - 10 V
... are within the preset limits. The synchronisers can be applied in conjunction with a wide range of prime movers, as its control pulses may be set to fit several types – from slow reacting diesel engines to fast reacting gas turbines. ...
... Modular protection relays | Timers and protection relays Technical Data For all conductive liquid Automatic resetting From 2,5K to 50K sensivity adjustable Din rail mounting 1 Exchange contact ...
Tripping current: 0.03 A - 30 A
Trigger voltage: 12 V - 400 V
... • Type A – Earth Leakage Relay • Local (and optional remote) Test/Reset buttons • Isolated Auxiliary supply • 1 x SPDT/1 x SPNO Relay outputs • 44mm wide, DIN Rail mount This product is used in conjunction with ...
Broyce Control
Tripping current: 5 mA - 10,000 mA
... adjustments • LED indicators for power supply, • contact and reaction timer On application of the supply voltage the output relay pulls in and the timing period ts starts. Current control with ...
HIQUEL
... level control mode – 1 level control mode -Choice of function PUMP UP, PUMP DOWN. -Adjustable time delay on the output (0.1 – 10s). -Sensitivity adjustable by a potentiometer (5-100kΩ). -Galvanically separated supply ...
Tripping current: 8 A
Trigger voltage: 205, 480 V
... -Sequence control and phase failure -Detection of regenerated phases of up to 85% of the nominal voltage -No delay in the maneuver when detecting an anomaly -Output contact.... Max. 8A 250 VAC -Format.... 17,5 x 90 x 58,5 mm -Fixing ...
Automatismos Control y Programación, S.L.
Tripping current: 10 A
Trigger voltage: 250 V
... The probe relay (Ex) SRA-100-U0 works in conjunction with conductive probes, as a level limit switch or control in conductive liquids such as water, alkalis and acids. A functional extra-low voltage according to VDE 0100 ...
Tripping current: 8 A
Trigger voltage: 250, 24 V
... Phase loss/sequence relay, very narrow module (18 mm) Codes and references - 10002484 UF3-200/400 Specifications - Power supply voltage: 3 x 200...450 VAC - Frequency range: 47...63 Hz - Power consumption: 1.9 W - Relay ...
Toscano Linea Electronica
Trigger voltage: 24 V - 230 V
... Overview
The AT-DR07 level
control
relay is an electronic receiver that supplies voltage to a sensor (electrode or level probe) to detect the presence of liquid and prevent water damage. When the liquid contacts ...
... Overview
The AT-DR50 level
control
relay for conductive liquids is a device used to monitor and regulate the level of water, aqueous solutions or certain chemicals in a tank, reservoir or industrial installation. ...
Tripping current: 5 A
... The Speed Relay is used to monitor the speed of a rotating shaft and detect if it rises or falls below a preset safety level. The DIN rail mounted speed relay can be used with any Rotech encoder, and with 4B’s WDA ...
... We supply a series of control and panel alarms from the high quality brand B/W Controls. From our range of B/W Controls products we can supply the 8040 Series control panel with control ...
Trigger voltage: 110 V - 600 V
... manufacture the high quality Model 1500 induction relay under the brand B/W Controls. The B/W Controls 1500 induction relay utilizes the liquid as an electrical conductor to complete ...
Trigger voltage: 230 V
... Frequency control unit SIGA •Integrated, adjustable soft start guarantees jerk-free starting of the vibration feeder •Electronic frequency control unit for continuously variable control of inductive ...
... to the safety position built-in manual control (access level 0 or 1) safety position contact by smoke control speed monitoring of voltage in the control circuit and the power circuit and phase inversion ...