- Electricity - Electronics >
- Switch and Relay >
- Control relay
Control relays
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
... Level control relay for conductive liquids Type 72.51 with Adjustable sensitivity (5…150) kΩ and 6 functions. Delay time (0.5 s or 7 s) selectable. Technical features: • Emptying or filling functions (6 functions) • ...
... analysis
Series
Series 70
Applications
Suitable for grid/generation interface systems, continuity ...
Tripping current: 16 A
... The 72 Series comprises level control relays for conductive liquids. Features include (according to Type): • Sensitivity fixed or adjustable (5…150kΩ) • 35mm rail (EN 60715) mount ...
Tripping current: 5 A - 15 A
Trigger voltage: 24 V - 240 V
... This Harmony RM35-JA relay allows monitoring of current control in single phase networks. This modular multi function single phase current control relay is ideal for monitoring of electrical ...
Schneider Electric
... The SEL-352 relay provides breaker failure protection, breaker control, and breaker monitoring. Features include a cost-saving data recorder and a sophisticated controller to reduce maintenance and manual operations. ...
Schweitzer Engineering Laboratories
Tripping current: 0.1 A - 336 A
Trigger voltage: 690 V
... The UER1 thermal overload relays range up to an insulation voltage of 690V and an operational voltage of 690V, and can be driven by both 50Hz and 60Hz. They can provide current overload protection and phase loss protection, and the setting ...
Trigger voltage: 24, 48 V
... Product type Device for permanent control of the MCCB's tripping circuit or safety circuits Technical characteristics Control network voltage 13...30 VAC/DC (version TCS-1) 24...60 VAC/DC (version TCS-3) Power consumption ...
Trigger voltage: 110, 240 V
... RSR-72 type relay for re-start and reacceleration is deigned to perform the automatic motor restarting, after control and protection device opening, as a consequence of a momentary line voltage interruption or drop-out. The ...
... MC1 or MC3 type. The front of the relay has a control panel that is used to adjust the reactive current where the relay will act. It has a LED that indicates the status of the relay. The ...
CIRCUTOR
... Applications WIs can be used in any application that needs to control the load: Power supply units for grinders or aggregate grinding units. Loads in extrusion machines Pump control Load on motors, ...
CIRCUTOR
Trigger voltage: 300, 350, 400 V
... Electronic relay for protection and continuous voltage monitoring. Protection against voltage surges, triggers at voltages higher than 265 V. Trigger time according to the voltage value less than or equal to: 300 V triggers after ...
CIRCUTOR
... _1: - It is possible to set a variety of response parameters by means of a 4 bit selection facility from an overriding control unit; - Analog output (2 V to 10 V) corresponding to the current speed; - The possibility of overriding ...
Tripping current: 5 A
Trigger voltage: 220, 240 V
... Overview
The AT-DR07 level
control
relay is an electronic receiver that supplies voltage to a sensor (electrode or level probe) to detect the presence of liquid and prevent water damage. When the liquid contacts ...
ATMI
Tripping current: 5 A
Trigger voltage: 220, 240 V
... Overview
The AT-DR50 level
control
relay for conductive liquids is a device used to monitor and regulate the level of water, aqueous solutions or certain chemicals in a tank, reservoir or industrial installation. ...
ATMI
Tripping current: 5 A
Trigger voltage: 220, 240 V
... detection in tanks and silos. When the level reaches the set point the float tilts and triggers start/stop of a pump or another control device. ATMI supplies a range of pear float switches in multiple versions suitable for diverse industrial ...
ATMI
Tripping current: 0.03 A - 3 A
... ELR-3B Earth Leakage Relays WITHOUT BUILT-IN Toroidal Transformer RELAY WITH ADJUSTABLE DELAY TIME AND SENSITIVITY Type B earth leakage relay. It is suitable for Direct current (DC), pulsating current, ...
FANOX ELECTRONIC
... This product is able to control the temperature of a motor room, as well as the temperature inside switchboards, which are defined by the lack of a motor room. The design in accordance to the EN 81-1 standard and compliance with the EU ...
FANOX ELECTRONIC
Trigger voltage: 230 V
... The ST/ST-D by Fanox are phase and temperature relays which serve as protection against phase imbalance, phase loss, phase sequence and over temperature. These are compatible with most motors that have a PTC sensor operation like elevators, ...
FANOX ELECTRONIC
... installations, such as switch-disconnectors, impulse relays (remote switches) and main switches. Impulse relays, also known as remote switches, are switching relays that switch on due to an electrical ...
Doepke Schaltgeräte GmbH
Tripping current: 3, 5 A
Trigger voltage: 154 V - 500 V
... • Monitors Phase Sequence,Phase Failure & Phase Asymmetry • 3P - 3W wiring configuration • Relay output: 1 C/O SPDT • Mounting : DIN-rail Brief Specifications Measuring Parameter : Phase Sequence, Phase Failure, Phase Asymmetry Electrical ...
Trigger voltage: 12 V - 240 V
... The Delay ON star/delta relay CRM-2T is mainly designed to provide an extremely high quality performance for any related applications the device will be used. The relay has the capability to control motor ...
ETI
Tripping current: 16 A
Trigger voltage: 230 V
... Relay that allows to extend the load of any telephone controller up to a 16 A load. • Operating temp. :0 ºC to +50 ºC • Degree of protection :IP 41 according to EN 60529 ...
ORBIS TECNOLOGÍA ELÉCTRICA
Trigger voltage: 24 V
... conductivity level controls whose working is founded on measuring the resistance between two or more electrodes dip into fluids under control. Liquid between a reference electrode and one or more level electrodes causes ...
... The MS2P48 relay is a phase failure relay suitable for 3 phase supplies. The relay is designed to automatically change over from the primary supply to the secondary supply if any phase of the primary ...
... With growth in technologically sophisticated and energy efficient systems around the globe, Kuhse DC-solenoids provide the optimum alternative to enhance the energy efficiency of systems . In order to align magnets more efficiently ,electrical components ...
Tripping current: 16 A
... Impulse Current Breakers are used to control lightning from two or more points. Traditionally, the need for controlling lightning circuits in larger areas from various points was met by using vavien-key system. Limited number of keys, ...
Federal Elektrik
AQ 101D is a sophisticated micro-processor based arc flash protection unit for arc light detection. It is designed to minimize the damage caused by an arcing fault (arc flash) by tripping the circuit breaker sourcing the fault current. The AQ 101D complete ...
Arcteq Relays Ltd
... General Asymmetry adjustable phase protection relays are designed to protect the threephased motors that is threaten by failures that is originated from network voltages. ...
Tense Electronic
Trigger voltage: 12 V - 60 V
... For transfer, safety grounding, or tap selection at 12kV to 60kV peak test in air. Most HV contacts have full insulation above ground. A higher insulation level to ground is optional. Most units are spring return, can mount in any position, or may ...
Tripping current: 16 A
Trigger voltage: 230 V
... Sigma Impulse Leakage Relay is used to provide control from two ore more points of the illuminating illumination. The most important advantage of the Impulse Leakage Relay switch is that it provides as ...
SIGMA ELEKTRIK
... -Multi-function relay(RTU Built-in) for LBS and EFI (N1 for LBS, N2 for EFI) -Voltage, Current and Power Metering, Open Phase, Live Load Block, Synchronism Check, etc. -Fault detection and indication (FI) (Phase, Ground, Residual ...
ENTEC ELECTRIC & ELECTRONIC CO.,LTD
... electronic control with high capacity of special relays. Control voltages 12V UC. Contact position indicator with LED. Control power demand 0.2W only. Safe disconnection to VDE 0106, ...
Eltako Electronics
... RL10: Universal relay for filling or emptying RL11: Level relay for emptying RL12: Level relay for filling 1 or 2 sensor levels Adjustable sensitivity 1- or 2-pole relay output DC supply ...
A monitoring relay is used to monitor and report values that exceed predefined parameters.
ApplicationsThese devices can be used to monitor electrical parameters, such as power factor, voltage, current or phase. They also monitor manufacturing parameters, including temperature, pressure, levels and frequencies.
TechnologiesAs with other relays, monitoring models may be electromechanical, though most now are semiconductor-based solid state relays. Some are directly programmable and are presented in ISO cases for rail installation.
How to chooseChoice depends on the intended application and the parameters to be monitored.
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group