- Electricity - Electronics >
- Switch and Relay >
- Current circuit breaker
Current circuit breakers
Primary current: 630 A - 4,000 A
VAC: 12 kV
... VAC83 VCB is in a new type indoor switch device, which is mainly used in three-phase AC power system with rated voltage of 12kV, and rated frequency of 50-60Hz. It has the advantages of compact structure, ...
Wenzhou Vacem Technology Co., Ltd
Primary current: 0 A - 1,600 A
VAC: 550, 800 V
... of a circuit breaker provides the feature of inverse time-delay, while the magnetic release is the instantaneous operation as shown on table 2(distribution circuit breaker) ...
Andeli Group Company
Primary current: 6,000 A
VAC: 230 V - 400 V
Rating: 2 A - 63 A
... - Tripping curve: B, C B - The maximum current release breaks between 3 and 5 In; used to protect long circuits and generators С - The maximum current release breaks between 5 and 10 In; used to protect ...
Elmark
... ZW32 outdoor High Voltage AC Vacuum circuit Breaker is a new generation outdoor vacuum circuit breaker researched and developed recently based on the foreign advanced ...
... not Degree of protection IP IP54 IK degree of protection IK07 Screw Type 1/4 back empty electrical enclosure / circuit breaker ...
Primary current: 40 A
VAC: 240 V
VDC: 50 V
... Circuit Breakers, Thermal, Series Trip, Silver, Operating Voltage 240 VAC, Operating Voltage 50 VDC, 40A Current Rating, Potter & Brumfield W23-31 • Circuit Breaker ...
Primary current: 1,250, 4,000, 3,150, 2,000, 2,500 A
VAC: 7.2 V - 40.5 V
... applications. The powerful 3AH3 vacuum circuit breakers were the first 63- and 72-kA vacuum circuit breakers on the market tested in accordance with IEEE C37.013 for load currents ...
Primary current: 0.25 mA
VDC: 12 V - 33 V
... conductor in case of a short- circuit, so that the short- circuit-free side can continue to operate. The line separator has 2x2 connectors for the detector line. Yellow LED for the status indication signals the short- circuit ...
Primary current: 40 mA
VDC: 19 V - 30 V
Rating: 30 A
... clamps Power losses, typ. - 7 W No-load losses, typ. - 1 W MTBF SN 29500 @ 40 °C (h) - 596000 h Features Eight current controlled outputs NEC Class 2 compliant Adaptive voltage-dependent current ...
PULS GmbH
Primary current: 1 A - 10 A
VDC: 12, 24 V
... channel electronic circuit breaker is designed for current distribution and protection of DC 12V or 24V load circuits. The MRF102 is Din Rail mounting or wall mounting. The ...
Primary current: 6,000 A
VAC: 230, 400 V
... SFB2A series circuit breakers are applicable for places with AC 50Hz or 60Hz, rated voltage of 400V and below, and rated current of 16A-80A. It is mainly used for overload and short- circuit ...
... special 40mA version of the well known E-T-A P106 thermal circuit breakers. It is particularly useful in applications where there is need to protect sensitive equipment that run on low current. Because ...
Primary current: 16 A
VAC: 230 V
... extension cables, all-pole disconnection, plug in accordance with DIN VDE 0661. Technical data - Rated tripping current - 30 mA (residual current) Housing dimensions - W 240 x H 190 x D 60 mm ...