Primary current: 32, 12 A
VDC: 600, 1,000 V
... Compact, ergonomic design • High terminal accessibility • Cover interlock with knob in "ON" position These DC isolator switches are ideal for photovoltaic systems, ensuring reliability in harsh conditions ...
BREMAS
Primary current: 32, 12 A
VDC: 600, 1,000 V
... Compact, ergonomic design • High terminal accessibility • Cover interlock with knob in "ON" position These DC isolator switches are ideal for photovoltaic systems, ensuring reliability in harsh conditions ...
BREMAS
Primary current: 12, 32 A
VDC: 600, 1,000 V
... Compact, ergonomic design • High terminal accessibility • Cover interlock with knob in "ON" position These DC isolator switches are ideal for photovoltaic systems, ensuring reliability in harsh conditions ...
BREMAS
Primary current: 16 A
VDC: 900 V
Modular DC Switch IP40 2 Pole 1 String Lever Specifications • Handle Type Lever Handle • Lockable N • Number of Strings 1 • Mounting Distribution Board • Temperature Range °C -40 to +65°C • ...
Primary current: 1,250, 2,000 A
VDC: 2 kV
... possible to equip the disconnectors with position switches for the indication of the switch position (… IS or …TS). The disconnectors 2000 A can be delivered in the following ...
Primary current: 58 A
VDC: 1,000 V
DC - Switch Disconnectors especially developed for Photovoltaic-Installations according to IEC 60364-7-712. DC-Switches: - High DC switching capacity: up to ...
Primary current: 800 A
VDC: 600 V
... Our standard Knife Switch range is rigorously engineered to meet your technical specifications in different configurations. Mersen has a switch solution that will meet your unique needs. Uses of ...
Primary current: 25 A - 45 A
VDC: 0 V - 1,000 V
... PV are DC load break switches. They make and break under load conditions and provide optimum safety isolation for any PV circuit. Advantages Compact Thanks to its compact design, the space needed within the combiner ...
Primary current: 25,000 A - 63,000 A
ZJW1-816 type/J25 grounding switch is installed at ± 800 kV converter station on the polar side of DC field and high voltage side of DC filter, used to be reliable grounding for the maintenance ...
Primary current: 252 A
VAC: 690 V
VDC: 440 V
module 4x NH fuse-switch disconnector, 3-pole screw connection 4x NH 000 (max. 63 A) for busbars 30, 40, 60, 80, 100, 120 x 10 NEW System 185Power Product group - 09 Subgroup - 37 pack size - 1 EAN ...
Wöhner
Primary current: 16, 25, 32 A
VAC: 300, 600, 800, 1,000, 1,200 V
RNIS32 Series DC Isolator Switch is applied to 1~20 KW residential or commercial photovoltaic system, placed between photovoltage modules and inverters. Arcing time is less than 8ms, ...
Primary current: 0 A - 32 A
VAC: 1,200 V
VDC: 1,200 V
ASL4-32 series DC Isolator Switches are applied to 1-20KW Inverter, Controller, DC Combiner Box, used for Residential or Commercial PV solar power system(on-grid/off-grid). Arcing time ...
Primary current: 0 A - 6,300 A
VAC: 0 V - 1,800 V
... components and solutions for DC traction power substations for the railway industry. Our SW-type off-load disconnector comes in a wide range of configurations and with optional features ...
Secheron
Primary current: 160 A
VAC: 1,500 V
... experience being the preferred DC switch-disconnector supplier for solar plants since 2007. • Frontal or side operation • Maximized electrical performance • High safety level • Suitable for extreme ...
Telergon
Primary current: 25, 40, 13, 20, 50 A
VDC: 1,500 V
Choose our line of isolation switches that are properly disengaged power when toggled. With a patented arc-extinguishing chamber, we guarantee better solar DC safety. Product Benefits Non-polarity ...
Aswich Electrical Co., Ltd
Primary current: 16 A - 32 A
VDC: 500, 600, 800, 1,000, 1,200 V
The first DC isolator to AS 60947.3:2018 DC-PV2 DC isolating switches must now have a valid Certificate of Conformity confirming the product complies with AS 60947.3:2018. ...
Zhejiang Benyi Electrical Co.,ltd.
Primary current: 1,000, 2,000, 4,000, 6,000 A
VDC: 750 V - 1,800 V
DC Disconnector Switch is used for no load switching in DC system. ET-DS design is compact and optimized to be integrated in DC switchgear and other ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining