Kimo’s HM 110 is a humidity sensor that has a measuring range from 5 to 95% RH. Measuring range from 5 to 95% RH 0-10 V output or 4-20 mA output With or without 10-digits LCD display "1⁄4 ...
Measuring range (%): 0 % - 100 %
Measuring range (temperature): -30 °C - 50 °C
Accuracy (temperature): 0.5, 2, 3 °C
... mode Medium: Temperature and Humidity Sensor: Single-chip sensor for humidity and temperature with digital signal transmission and calibration memory on the chip Measuring ...
Measuring range (%): 0 % - 100 %
Measuring range (temperature): -40 °C - 120 °C
Accuracy (temperature): 0.5, 2, 3 °C
... relative humidity with a „single-chip“-sensor • Digital transmission from sensor to the evaluation electronics • Sensor interchangeability without need for re-calibration Humidity-/temperature ...
Precision: 2, 3, 4 %
The Model SRH Humidity Series include wall mount, duct mount and outside air configurations in 2%, 3%, and 5% RH accuracy. The SRH Series ...
Humidity- and temperature Transmitter optimised for HVAC Features • Operating temp. up to 60 °C • Accuracy RH. :±3 % RH / 30…80 % RH • Accuracy T. :±0,8 K • With analogue output Humidity ...
Galltec Mess- und Regeltechnik GmbH
Humidity and temperature sensors optimised for HVAC Features • Operating temperature up to 80 °C • Accuracy RH: ±3 % RH / 30…80 % RH • Accuracy T.: ±1 K • Current ...
Galltec Mess- und Regeltechnik GmbH
... Accuracy H.: ± 2 % RH / 40…60 % RH • Accuracy T.: ± 0,2 K (voltage output) • Accuracy T.: ± 0,3 K (current output) • Robust • With capacitive humidity sensor The ...
Galltec Mess- und Regeltechnik GmbH
Quality product for HVAC sector, accuracy ± 2 % or ± 3 %Calibratable outdoor humidity ⁄ temperature sensor HYGRASGARD® AFF ⁄ AFTF (± 3 %) and AFF - 20 ⁄ AFTF - 20 (± 2 %) with plastic sinter filter (optional ...
Using thin-film sensor with capacitance changing proportionally to medium relative humidity, RHT measures RH of air and non-aggressive gases and converts it into standard 4...20mA 2-wire ...
Comeco Control & Measurement
Measuring range (%): 0 % - 100 %
Precision: 1.3 %
Measuring range (temperature): -40 °C - 180 °C
... mixture ratio By selecting a suitable housing version the humidity transmitter HLX31 can be used for the entire range of humidity measurement applications: • Model A: wall ...
Measuring range (%): 0 % - 100 %
Precision: 2 %
Measuring range (temperature): -40 °C - 100 °C
Temperature / Humidity Transmitter Temperature / Humidity Transmitter TRH-300D( Duct Type)_TRH-300W (Wall Type) Temperature / Humidity ...
... • Capacitive or fiber dilation sensors • Wall, chambers, process mounting models • Special length and remote sensor Transmitters • Special types for high temperature and pressure processes • Hand ...
Measuring range (%): 0 % - 100 %
Measuring range (temperature): -40 °C - 180 °C
Accuracy (temperature): 0.2 °C
... ..180 °C (-40...356 °F). It measures accurately relative humidity (RH) and temperature (T) and calculates the dew point (Td) and the frost point (Tf). EE23 is available for wall or duct mount, ...
E+E ELEKTRONIK
Measuring range (%): 0 % - 100 %
Precision: 2 %
Working temperature: -20 °C - 80 °C
... efficiency is improved Precise measuring of humidity for energy-efficient control of HVAC installations and monitoring energy consumption Features Measures the relative humidity and temperature in ...
Working temperature: 0 °C - 50 °C
Humidity transmitters with temperature output for duct that use Modbus serial communication protocol RHT-MOD Duct is a relative humidity transmitter ...
Minco humidity and humidity/temperature transmitters are designed using an advanced microprocessor. Digital signal processing allows these transmitters to precisely match the characteristics of the humidity ...
The RAF/A humidity sensor with transducer measures the relative humidity 0...100% r.H. of the ambient air by a capacitive sensor and transforms it to a standardised output ...
FuehlerSysteme eNET International GmbH
Measuring range (%): 0 % - 100 %
Measuring range (temperature): -20 °C - 80 °C
Accuracy (temperature): 0.3 °C - 23 °C
Pronem midi is provides to measure temperature and relative humidity and converts the values standart analog or digital signals for send to another system. - Accuracy (RH) - +/- 2 %RH (Typ) at 23 °C Stability (RH) ...
Precision: 1.5, 2 %
Accuracy (temperature): 0.2, 0.1 °C
... User-friendliness and expert's support through all stages of the life cycle Unlike others probe, HENGKO HT-606 temperature and humidity sensor peobe adopts wire mesh sensor ...
Humidity, material and temperature transmitter LF-TD Humidity transmitter for applications in laboratory and climate control, drying technology, wood pro-cessing industry, food industry, ...
... air humidity and temperature. The enclosure minimizes installation costs and provides outstanding protection against contamination and condensation, thus ensuring flawless operation. The FHT31 employs the new humidity ...
The FCX-OHS humdity transmitter is developed for different types of ovens (tunnel, vertical and serpentine) and to be able to work under the high temperatures and aggressive media present in these types of furnaces. The measurement is ...
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining