The pH / redox electrode system 2867 with industrial dip electrode is designed for pH and redox measurement in channels and open tanks. It is particularly suitable for use in effluent treatment applications ...
ABB Measurement & Analytics

... easy Measurement ranges from 0 to 1.999 µS/cm to 0 to 19.99 mS/cm Corrosion resistant 316 stainless steel measurement electrodes Pt100 or Pt1000 integral temperature compensation elements Maximum temperature 100 ...
ABB Measurement & Analytics

... configurations Measurement ranges from 0 to 1.999 µS/cm and 0 to 19.99 mS/cm Corrosion resistant 316 stainless steel measurement electrodes Pt100 or Pt1000 integral temperature compensation elements Anti-blowout lip on ...
ABB Measurement & Analytics

Reliable online measurement of ORP – with DULCOTEST® sensors Our product line of DULCOTEST® ORP electrodes provides a wide range of sensors for different measuring tasks. The field of application covers everything from ...

The InPro 3100 is a pH electrode with temperature sensor, designed for measurement in bioprocesses where CIP and SIP procedures are required. The 120 mm version is optimal for short installation lengths. Rugged pH Sensor ...
METTLER TOLEDO

The InPro 3100 is a pH electrode with temperature sensor, designed for measurement in bioprocesses where CIP and SIP procedures are required. The 120 mm version is optimal for short installation lengths. Rugged pH Sensor ...
METTLER TOLEDO

Gel-Filled Electrode for pH. The InPro 3100 is a pH electrode with temperature sensor, designed for measurement in bioprocesses where CIP and SIP procedures are required. The 150 mm version is optimal ...
METTLER TOLEDO

Combined platinum ring electrode with a pH glass membrane as reference electrode and integrated memory chip for storing sensor data. This maintenance-free electrode is suitable for redox ...
Metrohm

Intelligent, combined platinum ring electrode with integrated memory chip for storing sensor data. This electrode is suitable for redox titrations where the pH value varies, e.g.: Oxygen content ...
Metrohm

Intelligent, combined silver ring electrode with integrated memory chip for storing sensor data. This electrode is suitable for precipitation titrations when the pH value varies (titrant silver nitrate) ...
Metrohm

Water Analysis Meters & Electrodes Starter Electrodes OHAUS Precision Powers the Starter Electrodes Backed by our commitment to accurate and precise measurement, the OHAUS Starter ...

IDS ORP measurement for general applications IDS ORP electrodes are used to measure oxidation or reduction potentials in aqueous solutions - with integrated temperature sensor - Safe measured values due to signal ...
Xylem Analytics Germany Sales GmbH & Co. KG

... OPTISENS ORP 8590 is an ORP sensor for general water and wastewater applications. The sensor type is equipped with a platinum electrode, a large ceramic diaphragm and a temperature sensor (Pt100). It features a robust ...

The sension Gel-filled pH Electrode uses a silver/silver chloride reference element with a glass frit junction and a full-range pH glass that can be used in a wide variety of applications, especially at extreme levels ...

Ammonium-sensitive electrode system for measuring in potable water. Ammonium sensor: Sensor with ion sensitive membrane in mechanically and chemically inert plastic case (IP 68) with excellent life time. Reference ...
Swan Analytical Instruments

Nitrate-sensitive electrode system for measuring in potable water. Nitrate sensor: Sensor with ion sensitive membrane in mechanically and chemically inert plastic case (IP 68) with excellent life time. Reference ...
Swan Analytical Instruments

Fluoride-sensitive electrode system for measuring in potable water. Fluoride sensor: Sensor with ion sensitive membrane in mechanically and chemically inert plastic case(IP 68) with excellent life time. Reference ...
Swan Analytical Instruments

... ULTRAPEN™ PT3 High Performance Features: • - Accuracy of ±10 mV ORP • - Proprietary Sensor Design • - 99.9% Pure Platinum Electrode • - 3 Calibration Options with Automatic Solution Recognition • - Automatic Temperature ...

... refillable, double junction pH electrode that has a built-in temperature sensor. This probe features a 3.5 mm connector designed exclusively to be used with Hanna Instruments edge® Tablet Meters. The HI10530 electrode ...
Hanna Instruments

High quality pH electrode based on combined electrode technology. The perforated membrane combined with a polymerized solid electrolyte makes this electrode particularly insensitive to ...

... manufactures an extensive range of electrochemical electrodes - combined pH, glass or reference electrodes, metal electrodes, ion-selective electrodes ...

... is necessary to calibrate the electrode after start-up and then in regular time intervals. 4.A combined electrode must not drain at the active tip, otherwise it becomes useless. To recover the active ...

The UCP1A contact probe is a lightweight and versatile instrument that provides a means of carrying out underwater cathodic protection potential measurements. It has been specially designed for use with manned or Remotely Operated ...
Buckleys (UVRAL) Limited

The UCP1B proximity probe is a lightweight and versatile instrument specifically designed to carry out underwater cathodic protection potential measurements. The probe has been developed for use with manned or Remotely Operated Vehicles ...
Buckleys (UVRAL) Limited

... connected to a separate high impedance voltmeter (greater than 10 meg Ohm). The electrode is housed in a PVC body with holes to allow the easy flow of water around the electrode. The Half Cell is supplied ...
Buckleys (UVRAL) Limited

... Professional ORP electrode with high accuracy and extreme reliability. * Silver-silver/chloride reference gel. * Epoxy body, BNC connector and 2 meters cable. * 12.5 mm Dia, x 150 mm length. * Range : -2,000 to 2,000 ...

ORP & Temperature combinated sensor, with interchangeable "Plastogel" cartridge Compact, rugged & lightweight DELRIN handle Modbus RS485 Communication or SDI12. Measurment ranges:ORP: -1000 à +1000 mVT°: -10°C à + 50°C 9 armored connectors, ...

The HI1230B is a PEI body, double junction pH electrode with a BNC connector. This electrode has a single ceramic junction in the outer reference cell and the spherical pH sensing portion is made with ...

... proprietary to meters that use digital electrodes. The matching pin integrated into the HI11311 is for the Sensor Check™ capability of the edge pH meter; this feature is used to identify problems with the pH electrode ...

Exchangeable Tip pH Electrode GSS‐304B(KCl Replenish-Free) / GSS‐314B(KCl Refillable) - Easy-to-replace electrode tip and reference electrode junction tip - Alkali-resistant glass ...
DKK-TOA CORPORATION

Description The unique sealed membrane allows ease of use of the DO2 sensor without the need for spare membranes and refilling solutions whilst still guaranteeing accurate results and long life.
SENTEK Ltd.

... be sure to check out our wide selection of electrodes for all TruLab benchtop meter models! IoLine Micro - 3 in 1, pH electrode, Triple Junction, Iodine/Iodide reference, 3 in 1, Refillable, Micro ...

Basic three-electrode approach with one working electrode (WE), reference electrode (RE) and auxiliary electrode (AE). Ideal for electroanalysis, flow systems, nanotechnology ...

... Dimensions: 10 x 6 x 0.75 mm Substrate: Glass Insulating layer: EPON SU8 resin Electrochemical cell: 3.5 mm Ø Electrodes material: Ti / Au and Ti/Pt Electrodes thickness: 50/150 ...

calomel electrode for measurements in very small volumes long-term stable (electrolyte with saturated KCl solution and KCl reserve) shaft diameter: 5 mm standard glass cone (NSK 7) is available → for gas tight mounting ...
Sensortechnik Meinsberg GmbH

The Princeton Applied Research Model 616A Electrode Rotator is a high precision, low mass rotator that performs well with virtually any potentiostat. When connected to Princeton Applied Research electrochemical ...
Princeton Applied Research

The DrDAQ redox sensor (also known as an ORP sensor) can measure redox potential in the range of –1500 mV to +1500 mV. Positive readings indicate an oxidizing agent (addition of oxygen), while negative readings indicate a reducing agent ...

Closed electrode shaft No topping up of KCl electrolyte required Protected reference system of the integrated reference electrode with long diffusion path of up to 120 mm Significantly longer service ...
DOSATRONIC GmbH

... corresponds to a dosage of 1:100 Average dosage tolerance: ± 5 % Reproducibility: ± 3 % (API675) Scope of supply PHGB2 glass electrode with PG 13.5 thread 0.8 m fixed cable and BNC plug with red cap Wetting cup ...
DOSATRONIC GmbH

... with long service life Scope of supply PHGK-2 glass electrode PHPK-2 electrode with polysulfone shaft Areas of application PHGK-2 (glass shaft): Process and wastewater applications, water treatment ...
DOSATRONIC GmbH
Your suggestions for improvement:

An electrode usually is a device for measuring electrochemical parameters, such as pH, redox potential or ionic concentration. Other types include those used in arc welding, soldering or grounding.
ApplicationsGlass and reference electrodes measure the pH of organic substances, or of biological or biochemical samples. Arc welding electrodes are used to join steel, stainless steel, iron or cast iron elements.
TechnologiesMeasuring pH involves a glass electrode and a standard electrode, usually immersed in a saturated calomel solution. This creates a galvanic cell whose generated voltage is used to calculate pH. An ion-selective electrode uses the same principle to measure the concentration of a specific ion. An ORP electrode measures oxidation reduction potential.
Arc welding electrodes have a core (steel or an alloy of copper, nickel or chromium) coated with a flux material. The electric arc melts the core material and deposits it at the weld point. The coating is a complex mixture which helps create the arc, strips the surface for proper flux deposit and protects the weld area from oxidation.
Electrochemical electrodes are characterized by the nature of the constituent glass or metal and that of the electrolytes employed. Welding rods differ by core material.