- Health - Safety - Environment >
- Air Treatment and Noise Management >
- Extraction fan
Extraction fans
Air flow: 60 m³/h
Diameter: 300 mm
Noise level: 85 dB
... Used for ventilation and exhaust in underground mining, shipyards, refineries, and the petrochemical industry. Suitable for extraction-type local ventilation in coal mines with high gas concentrations, ventilation and air exchange in ...
Rosit GmbH
Air flow: 350 m³/min
Diameter: 600 mm
Noise level: 96 dB
... Used for ventilation and exhaust in underground mining, shipyards, refineries, and the petrochemical industry. Suitable for extraction-type local ventilation in coal mines with high gas concentrations, ventilation and air exchange in ...
Rosit GmbH
Air flow: 0 m³/min - 230 m³/min
Rotational speed: 3,500 rpm
Noise level: 89 dB
Used for ventilation and exhaust in underground mining, shipyards, refineries, and the petrochemical industry; for exhaust-type local ventilation in coal mines with high gas concentrations; for air exchange in oil depots and ship holds with high oil and ...
Rosit GmbH
Air flow: 5,830 m³/h - 29,900 m³/h
... Hz (≤ 4 kW) and 400/690 V 50 Hz (> 4 kW). - Operating temperature: -20 ºC +40 ºC. These medium pressure centrifugal extractors are equipped with reaction turbines designed to provide optimal performance in demanding environments. ...
A2S Advanced Safety Solutions
... prevent any ignition in dangerous atmospheres. These extractors are particularly suitable for use in environments where hydrogen is present, offering a reliable and secure solution for air and gas extraction. Ambiant ...
A2S Advanced Safety Solutions
Air flow: 12,530 m³/h - 47,670 m³/h
Noise level: 57 dB - 85 dB
... cable gland included. - Steel sheet suction ring with aluminum strip on the helix area according to EN 14986. - Standard marking with explosion engine (ex dB): II 2g ex h iB + H2 T4 GB. These helical extractors are ...
A2S Advanced Safety Solutions
Air flow: 25 m³/h
... always recommend that safety cabinets are operated with an extraction fan (min. air exchange rate 10 times per hour) for proper operation in accordance with TRGS 510, annex 3! If an extraction fan ...
Air flow: 0 m³/s - 1.53 m³/s
Diameter: 300 mm
Rotational speed: 5,000 rpm
... Stationary pneumatic axial fan with 300 mm nominal diameter for various ventilation work. Suitable for e. g. tank aeration, cleaning work and many other applications in explosive areas. Earthing required. ...
Air flow: 12,050, 14,950, 10,550 m³/min
Diameter: 6,100, 7,300, 5,500 mm
Rotational speed: 55, 63, 58 rpm
... Natural Ventilation:The ventilation solutions such as small fans, air conditioners, and exhaust fans are subject to many restrictions in tall and wide enclosed space.while large Industrial HVLS fans can ...
WANSHSIN SEIKOU (HUNAN) CO., LTD.
Air flow: 13,000, 16,000, 23,000, 30,000 m³/h
... steel cylinder and larger separation section. The Varifan air volume adjustment ensures optimal conditions. Cimbria ACG axial fans are also available for applications that do not require dust separation. • Promotes equipment efficiency ...
Air flow: 2,000 m³/h
Diameter: 100, 150, 160 mm
Noise level: 68 dB
... - Mobile suction fan for aeration and ventilation - Large amounts of smoke/dust - Continuous use FEATURES - Portable and mobile - Exhaust air hoses of Ø 100 mm, Ø 150 mm, Ø 160 mm can be connected TECHNICAL ...
Air flow: 592 m³/h - 64,825 m³/h
Rotational speed: 910 rpm - 2,800 rpm
... casing is removed, it can be used as a free fan. It can also be installed in series at intervals in longer exhaust pipes to increase the wind pressure in the pipes. The BT35-11 explosion-proof axial flow fan adopts explosion-proof ...
Air flow: 1,900 m³/h - 3,200 m³/h
Air flow: 2,000 m³/h - 5,200 m³/h
Rotational speed: 2,850 rpm
Noise level: 70 dB
... TopAir Systems offers high-quality outdoor centrifugal fans. The roof/side wall fans are weather resistant, built upon on a PVC structure and polypropylene impeller. The motor offers a 3 Phase 200-380V 50Hz power supply, ...
Air flow: 500 m³/h - 9,100 m³/h
Noise level: 64 dB - 88 dB
... in ducts. Furthermore, they have a low noise level. Construction: Body in steel sheet with anti-corrosion epoxy coating. Fan in galvanised steel sheet. Two threaded holes M20x1.5. ...
Air flow: 468 m³/h - 2,390 m³/h
... with no maintenance needs, for electric boards air exchange/ extraction. Designed and produced in Italy; characterized by steel sheet housings and finned lower base; high-head centrifugal- fans generated flow; more than ...
Air flow: 2,300 m³/h - 115,000 m³/h
Diameter: 310 mm - 1,600 mm
Rotational speed: 750, 1,500, 1,000 rpm
... Smoke extraction in case of fire, 300/400°c for 120 minutes. • Smoke extraction • Pressurization • Industrial ventilation & explosion-proof application Multiple european laboratories, BSI KITEMARK, APPLUS. ADVANTAGES DUCT- ...
... Ventilators Essential machine for the pneumatic conveying, product conditioning and dust extraction, the ventilators supplied by Sangati Berga are projected according to the calculus methodology proven worldwide. Gathering over 50 ...
... The exhaust fan is an indispensable machine which carries the grape stalks that come out of the grape-destalker to the place in which they will be gathered. These models are entirely in stainless-steel and it is possible to combine them ...
Air flow: 900 m³/h - 4,500 m³/h
Rotational speed: 1,200 rpm - 1,460 rpm
Noise level: 55 dB - 72 dB
... Explosion Proof Certified Axial fans to extract air and fumes directly outside through short ducting, wall or panel mounting. ...
Siccis
Air flow: 0 m³/h - 0 m³/h
Rotational speed: 1,400 rad.min-1 - 16,965 rad.min-1
Noise level: 52, 54, 46, 48 dB
... expectancy: 30.000 hours Mounting type: Grid Fan (standard) Round Frame Fan (type R) Cylinder Fan (type T) Square Frame ...
Air flow: 1.63, 2.45 m³/s
... to reduce the concentrations of polluted air and to assist with the extraction of smoke trapped in car parks, in the event of a fire. It is a low profile, high velocity induction fan, which controls air movement in underground ...
Colt International Ltd
Air flow: 327 m³/h - 542 m³/h
... kitchen aspirator MRH-75-90 This kitchen aspirator is designed with one Ventilation centrifugal fan,2-speed adjustment,100% copper wire motor drive; The housing use SPCC material and perfect powder Spray smooth surface treatment and ...
Air flow: 700 m³/h - 15,000 m³/h
... Axial fan low pressure Installation: hazardous areas - Zone 1 / 2 (Gases) Classification: Group II - Category 2G ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group