- Hydraulics - Pneumatics >
- Valve >
- Gas pressure regulator
Gas pressure regulators
Pressure: 0 bar - 200 bar
Orifice diameter: 6.3, 0.07 mm
A single stage regulator for nitrogen reducing the inlet pressure from 200bar to any pressure between 0 and 200 bar. One of the main application used onboard is for pressure ...
Wilhelmsen
Pressure: 0 bar - 200 bar
Orifice diameter: 0.375 in
... constant pressure. Apart from replacing damaged or faulty gauges, repairs should never be attempted on gas regulators. Faulty, old or corroded regulators should be ...
Wilhelmsen
Pressure: 10 bar - 200 bar
... single stage regulator for nitrogen reducing the inlet pressure from 200bar to any pressure between 0 and 10 bar. Apart from replacing damaged or faulty gauges, repairs should never ...
Wilhelmsen
Pressure: 10, 16, 25, 40 bar
Flow: 1 m³/h - 200 m³/h
Orifice diameter: 15 mm - 150 mm
Regulators are used to control preset pressure in process installations connected to regulator valve outlet. They are used in district heating systems, industrial ...
Pressure: 0 bar - 220 bar
Flow: 0.7, 0.8, 0.9 m³/h
Orifice diameter: 15 mm - 20 mm
... piston sensing pressure reducing valves. These regulators are designed for use with nitrogen, compressed air, water and other gases and liquids compatible with the materials of construction. They are ...
Pressure: 0 bar - 8 bar
Orifice diameter: 10 mm
Temperature: 0 °C - 70 °C
Compact pressure regulator, Push-in connector for hose 10, G 1/4, Piston pressure regulator with self-relieving design, hollow bolt and pivoting ring piece. The regulator ...
RIEGLER & Co.KG
Pressure: 0.8 bar - 85 bar
Temperature: -10 °C - 60 °C
PILOT-OPERATED GAS PRESSURE REGULATORS Aperflux 101 The Aperflux 101 is a pilot-controlled pressure regulator for medium and high pressure. Aperflux is a "fail open" ...
PIETRO FIORENTINI
Pressure: 5 bar - 18.9 bar
Orifice diameter: 2, 3, 4 in
Temperature: -10 °C - 60 °C
PILOT-OPERATED GAS PRESSURE REGULATORS Aperval 101 The APERVAL 101 is a pilot-controlled regulator for low- and medium-pressure applications. The APERVAL 101 is a fail-to-open ...
PIETRO FIORENTINI
Pressure: 0.5 bar - 102 bar
Orifice diameter: 1 in - 12 in
Temperature: -10 °C - 60 °C
PILOT-OPERATED GAS PRESSURE REGULATORS Reflux 819 Reflux 819 is a downstream pilot-controlled pressure regulator for medium and high pressure applications. It is particulary ...
PIETRO FIORENTINI
Pressure: 100 bar
Pilot-operated Gas Pressure Regulator According to DIN EN 334 (operating with auxiliary energy from the inlet pressure range) Application Device for transfer stations in gas transport ...
RMG
Pressure: 0 Pa - 0.35 Pa
Orifice diameter: 50 mm - 80 mm
Gas Pressure Regulator with Spring-loaded Measuring Unit Application Device for offtake stations in gas distribution as well as commercial and industrial facilities High-capacity ...
RMG
Pressure: 0 bar - 0.5 bar
Orifice diameter: 50 mm - 150 mm
Gas Pressure Regulator with Spring-loaded Measuring Unit Application Device for maintaining zero pressure in gas regulating lines (e.g., for installation before gas ...
RMG
Pressure: 0.5 bar - 20 bar
Flow: 1.3 m³/h - 7.5 m³/h
Orifice diameter: 15 mm - 50 mm
... adapter 4 Mankenberg clamp system Easy maintenance Exchangeable control parts Easy change of pressure ranges Balanced cone Downstream pressure control independent ...
Pressure: 16, 1.5, 3 bar
Pressure: 0.8 bar - 4 bar
Flow: 30 m³/h
Orifice diameter: 25, 50 mm
Pressure: 50, 10, 15, 16 bar
Flow: 50, 100 m³/h
Temperature: -20 °C - 60 °C
Application: For high purity gases and high pressure applications requiring high flow and precise outlet pressure, such as for laser applications and nuclear research. Key Advantages: Outstanding ...
Rotarex
Pressure: 10, 3, 1 bar
Flow: 2, 2.5, 3.5 m³/h
Temperature: -20 °C - 60 °C
... mildly corrosive gas applications requiring a very stable outlet pressure together with a very sensitive set up of this outlet pressure Key Advantages: Based on the proven S 20 bellows ...
Rotarex
Pressure: 1, 1.5, 3, 10 bar
Flow: 1.5 m³/h - 3.5 m³/h
Temperature: -20 °C - 60 °C
Key advantages - Bellow technology permits a large range of accurate outlet pressures in a compact design - Flexible mounting options on wall or panel - Acetylene version available (AD)
Rotarex
Pressure: 0 bar - 16 bar
Orifice diameter: 4 mm - 10 mm
Temperature: -10 °C - 70 °C
Parker Legris pressure regulators stabilise at the maximum determined value of the pressure delivered to the pneumatic equipment at any given fluctuations of the pressure ...
Pressure: 31 bar
Orifice diameter: 9 mm - 66 mm
... code. Unlike some competitive models of low side regulators that utilize high pressure discharge gas as a pilot source, they are piloted with upstream pressure. This ...
Parker Refrigerating Specialties Division
Temperature: 0 °C - 50 °C
... , 430 stainless steel and Sandvik® 1802 • Brass Orifice Applications: Volumetric Flow Control Carrier Gas Pressure Control Air over Liquid Flow ...
Parker Precision fluidics Division
Pressure: 241, 27.6 bar
Orifice diameter: 0.25 in
Temperature: -40 °C - 74 °C
... purity single-stage regulator for specialty, flammable, and industrial gas flows of less than 5 SCFM / 141 SLPM. Its diffusion-resistant metal diaphragm seal ensures gas purity and integrity. ...
Emerson Automation Solutions - TESCOM
Pressure: 0.07 bar - 34.5 bar
Flow: 1.7 m³/h
Orifice diameter: 1, 0.25 in
... Series regulators are direct-operated, pressure reducing regulators that resist hydrate formation and regulator freeze-up typically used on high-pressure ...
FISHER REGULATORS
Pressure: 0 bar - 17 bar
Flow: 0.37 m³/s
Orifice diameter: 0.25 mm
... diaphragm, insures a constant output pressure even during wide supply pressure variations. Stability of regulated pressure is maintained under varying flow conditions through the use ...
Pressure: -1 bar - 40 bar
Temperature: -20 °C - 70 °C
... energy efficiency is improved Control and monitoring according to needs and with no auxiliary energy. Features Switching point can be adjusted Sealable Pressure sensor made of brass for non-aggressive ...
Pressure: 10,000, 16 mbar
Flow: 13 l/min - 140 l/min
Orifice diameter: 68, 83, 117 mm
... please. Description: he low pressure regulator is manually adjustable. Version R01-2/-3/-4 has an integrated safety valve which opens at a pressure of 1.5 times of the max. outlet ...
AirCom Pneumatic
Pressure: 75.84 bar
Orifice diameter: 6 mm - 15 mm
Single seated and self-actuating compact diaphragm-type regulators covering a wide range of designs and operating pressures A series regulators are suitable for a variety of applications ...
Pressure: 0.5 bar - 220 bar
Orifice diameter: 0.75 in - 1 in
... Pneumatic Loaded Pressure Reducing Regulators developed by Tartarini. They use high pressure gas in compression with cylinders in applications of regulating ...
Tartarini
Pressure: 15 MPa
Orifice diameter: 25 mm - 300 mm
Temperature: -20 °C - 60 °C
... pilot-operated regulator which function is to supply constant outlet pressure and ensure supplying flow continually, suitable for all non-corrosive gases after purification treatment. The PL3000 is especially ...
Terrence Energy Co.,Ltd.
Pressure: 0.01 bar - 4 bar
Orifice diameter: 15 mm - 150 mm
* Gas regulator /governor for gaseous media, to be fitted to all types of gas consuming appliances. * Design incorporates inlet pressure compensation diaphragm ensuring ...
Avcon Controls PVT. Ltd.
... and multi-stage regulators suited to most fuel gas welding, cutting and heating processes and compressed gases. Premium Models At the high end of the spectrum, our premium range represents the gold ...
Pressure: 0 psi - 870 psi
Orifice diameter: 0.25, 0.38 in
Temperature: -20 °C - 90 °C
Piston controlled regulator Gas and liquid 0 valve according to the required flow Ni tri le or vit on seal Seat packing KELF or PTFE Working température according to 90° angle pattern or in line ...
HYDROPNEU TECHNOLOGIC
Pressure: 0 bar - 0.7 bar
... or more torches to a single Oweld gas generator. When it is used? It is used in case of multi-torches connected to a single Oweld gas generator. Where it is installed? EPR is installed between ...
Pressure: 0 bar - 70 bar
Flow: 800, 180, 150 l/min
Orifice diameter: 0.13 mm
... actuator. The pressure sensor measures the pressure of the fluid and sends a signal to the control circuit. The control circuit then compares the measured pressure ...
Genn Dih
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining