- Metrology - Laboratory >
- Analytical Instrumentation >
- Gas transmitter
Gas transmitters
The EC96 is manufactured by Systech Illinois, and is an oxygen deficiency monitor that is suitable for use in steadily regulating oxygen levels in a variety of sites such as tight working area, inert storage sites, and places where low or high degrees ...
... Gas detectors GA-300.A are intended for detection of toxic gases. Electrochemical sensor elements. Non intrusive calibration without opening the enclosure using magnetic calibration nozzle UGC-01. Plastic enclosure ...
Gas Sense
... Mount Trace O2 transmitter, two wires loop-powered is intrinsically safe when used in conjunction with MTL-7706 safety barrier. User selectable any range from 0-5 PPM to 0-25%. Signal output is locked on the selected range. Recovery from ...
... Oxygen Gas Transmitter gas transmitter: Vasthi Model VT-90-O2, oxygen gas transmitter deficiency sensors are non-intrusive “Smart Oxy meter” sensors ...
vasthi instruments
ExTox Gasmess-Systeme
... Specifications: 1. Gas detected: Carbon Dioxide (CO2) 2. Sensing element: Non-Dispersive Infrared Detector (NDIR) 3. Accuracy: ±40ppm + 3% of reading 4. Calibration interval: ABC Logic Self Calibration System 5. Response ...
Tongdy Control Technology
... The Model S4100C Intelligent Sensor is a microprocessor-based transmitter with integral three-digit readout. It is designed to measure and display concentrations of combustible gases in the 0-100% LEL range, but will continue to display ...
General Monitors
Carbon monoxide detector with electrochemical cell. Designed for installation on pillars or walls. Connection to 2 wires without polarity. Certified according to standard UNE 23300:1984
... precise measurement of oxygen (O₂) concentration. It is designed for
air quality monitoring and personnel protection.
Applications and main functions
- O₂ transmitter for ambient air monitoring
... accurate concentration readings. Intended for
air quality monitoring and personnel protection, it is suitable for sensitive and demanding environments.
Functional summary
- NH3 transmitter for ambient
... Supply voltage: 12...28 V DC Measuring range: 0...300 ppm Outputs: 4...20 mA, 2-wire / 0...10 V DC, 3-wire Calibration: Automatic zero point adjustment Degree of protection: IP56 Accuracy: ± 3% ...
... Supply voltage: 12...28 V DC Measuring range: 0...20 ppm Outputs: 4...20 mA, 2-wire / 0...10 V DC, 3-wire Calibration: Automatic zero point adjustment Degree of protection: IP56 Accuracy: ±3% ...
... Features:Suitable for HVAC. Various installation types. Sensor type:NDIR sensor Measuring range:2000 / 5000 / 10000 PPM Output:4 ... 20 mA / 0 ... 10 V Accuracy:±40 or ±250 PPM ±3% of reading IP rating:IP54(GS43) / IP64(GS44) ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group