Glass capillary viscometers

4 companies | 22 products
exhibit your products

& reach your clients in one place, all year round

Exhibit with us
{{#pushedProductsPlacement4.length}} {{#each pushedProductsPlacement4}}
{{product.productLabel}}

{{product.productLabel}} {{product.model}}

{{#if product.featureValues}}
{{#each product.featureValues}} {{content}} {{/each}}
{{/if}}
{{#if product.productPrice }} {{#if product.productPrice.price }}

{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{/if}} {{/if}}
{{#if product.activeRequestButton}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement4.length}}
{{#pushedProductsPlacement5.length}} {{#each pushedProductsPlacement5}}
{{product.productLabel}}

{{product.productLabel}} {{product.model}}

{{#if product.featureValues}}
{{#each product.featureValues}} {{content}} {{/each}}
{{/if}}
{{#if product.productPrice }} {{#if product.productPrice.price }}

{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{/if}} {{/if}}
{{#if product.activeRequestButton}}
{{/if}}
{{product.productLabel}}
{{product.model}}

{{#each product.specData:i}} {{name}}: {{value}} {{#i!=(product.specData.length-1)}}
{{/end}} {{/each}}

{{{product.idpText}}}

{{productPushLabel}}
{{#if product.newProduct}}
{{/if}} {{#if product.hasVideo}}
{{/if}}
{{/each}} {{/pushedProductsPlacement5.length}}
glass capillary viscosity meter
glass capillary viscosity meter
TV4000AKV

... complies with test methods ASTM D445, IP 71 and ISO 3104 using an Ubbelohde viscometer. The viscosity of Newtonian fluids can be most precisely determined using glass capillary viscometers. ...

capillary viscometer
capillary viscometer
AIVC series

The Asphalt Institute Vacuum Viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 3 mL. Minimum bath depth is 180 mm (7.1 in). Viscometers are ...

See the other products
Cannon Instrument Company
capillary viscometer
capillary viscometer
BS/IP/MSL series

... /MSL Miniature Suspended Level Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 4 mL. Minimum bath depth is 305 mm (12 in). Viscometers ...

See the other products
Cannon Instrument Company
capillary viscometer
capillary viscometer
BS/IP/RF series

The BS/IP/RF U-Tube Reversed Flow Viscometer measures kinematic viscosity of opaque Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 mL. Minimum bath depth is 280 mm (11 in). Viscometers ...

See the other products
Cannon Instrument Company
capillary viscometer
capillary viscometer
BS/IP/SL series

The BS/IP/SL Suspended Level Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 11 mL. Minimum bath depth is 250 mm (10 in). Viscometers ...

See the other products
Cannon Instrument Company
capillary viscometer
capillary viscometer
BS/IP/SL(S) series

... IP/SL(S) Suspended Level Short Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 10 mL. Minimum bath depth is 230 mm (9 in). Viscometers ...

See the other products
Cannon Instrument Company
capillary viscometer
capillary viscometer
BS/U/M series

The BS/U/M Miniature U-Tube Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 2 mL. Minimum bath depth is 230 mm (9 in). Viscometers ...

See the other products
Cannon Instrument Company
capillary viscometer
capillary viscometer
BS/U series

... U-Tube Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 mL (size A-C); 12 mL (size D-F); 23 mL (size G-H). Minimum bath depth is ...

See the other products
Cannon Instrument Company
capillary viscometer
capillary viscometer
CFOU series

... Cannon-Fenske Opaque Viscometer measures kinematic viscosity of transparent and opaque Newtonian liquids according to ASTM D445, ISO 3104 and ASTM D2170. Minimum sample volume is 12 mL. Minimum bath depth is 230 mm (9 ...

See the other products
Cannon Instrument Company
capillary viscometer
capillary viscometer
CFRU series

... Cannon-Fenske Routine Viscometer measures kinematic viscosity of transparent Newtonian liquids according to ASTM D445 and ISO 3104. Minimum sample volume is 7 mL. Minimum bath depth is 203 mm (8 in). Both calibrated and ...

See the other products
Cannon Instrument Company
capillary viscometer
capillary viscometer
CMSMEU series

... additional sample). Minimum bath depth is 230 mm (9 in). Both calibrated and uncalibrated viscometers are available. Calibrated viscometers include a certificate of calibration and instruction sheet. ...

See the other products
Cannon Instrument Company
glass capillary viscometer
glass capillary viscometer
46460 series

KIMBLE® KIMAX® Canon-Fenske Viscometer Tube Uncalibrated and Serialized • Complies with ASTM Specification D446 • Manufactured from borosilicate glass 3.3 • Permanently marked with an individual serial ...

glass capillary viscometer
glass capillary viscometer

MSE designs and manufactures glass viscometer up to 1800ºC. Features Tmax: 1800ºC Double-layers steel construction epoxy painted galvanized coating PID Control Able to resume the program ...

exhibit your products

& reach your clients in one place, all year round

Exhibit with us