- Electricity - Electronics >
- Cable, Connector, Enclosure >
- Insulated electrical cable
Insulated electrical cables
... Specification: 3x0.6 Conductor: Tinned copper Inner jacket: PE Outer jacket;PUR Breaking strength: 2000KG ...
Derulcable (Shanghai) Co., Ltd
... systems. H1Z2Z2-K Twin cables; are suitable for UV rays, ozone, bad weather conditions and is made of cross-linked material that does not contain halogen gas. They are resistant to fire and do not transmit flame. Optimized cable ...
Ege Kablo Endustri Malz. San. ve Tic. A.S.
Nominal voltage: 1,200 V
Temperature: -40 °C - 80 °C
... Multicore cables, PVC Conductor: bare copper acc. to EN 13602 Stranding: 18x0,10mm Core Isulation: PVC acc. VDE 0207 / EN 50363-3 Color code cores: DIN 47100 Outer sheath: PVC acc. to VDE 0207 / EN 50363-4 Jacket Colour: RAL ...
MediKabel GmbH
... CUSTOM-MADE PRODUCTION: Formats and structures of cables made on request. Know-how: - Notching - Fitting - Stripping + crimping ...
Nominal voltage: 1,000, 600, 1,800 V
Temperature: -40 °C - 90 °C
Cross-section: 1.5 mm² - 120 mm²
... Conductor: Tinned fine Re copper strands, according to VDE0295/IEC60228.Class5 Insulation: Polyolefin Copolymer electron-beam cross-linked Sheath Jacket: Polyolefin Copolymer electron-beam cross-linked Nominal Voltage: Uo/U=600V/1000VAC,1000/1800VDC Test ...
Temperature: -5 °C - 70 °C
... Universal cable A/I-DQ(ZN)BH 1x12E9/125 OS2 FO-Cab A/I-DQ(ZN)BH 1x12 OS2 Dca Universal cable A/I-DQ(ZN)BH 1x12E9/125 OS2 12x Singlemode OS2 yellow 2000 m Dca s2 d1 a1 ...
Nominal voltage: 450, 750 V
Temperature: -60 °C - 200 °C
... copper wire 4, insulation: silicone rubber 5, protective cover: silicone rubber 6, color: red / yellow / blue / white / black / yellow green / brown / green, etc. Features/USES Can be used in long-term humid environment, ...
Shanghai Shenyuan High Temperature wire Co., Ltd
Nominal voltage: 300, 450, 500, 750 V
Temperature: -15 °C - 70 °C
... Application: Flat Traveling Cable to connect machine room with elevator car Properties: 1.PVC insulation, PVC sheath 2.Rated voltage AC 300/500V. Rated temperature -15℃-70℃ 3.The conductor consists of multi-copper, tinned is available ...
Hangzhou Jiayuan Industrial Co., Ltd.
Nominal voltage: 300 V
Cross-section: 0.75 mm²
... Camera Cable Item: RG59+Power Standard: BS6500 Voltage: 300 V Conductor: Cu/ CCS Material:Form PE+Al-foil+Braid/ PVC Section: 0.81±0.01 mm Power cored: 2*0.75 mm² Application: Used in ...
Huzhou Permanent Cable Co., Ltd.
Nominal voltage: 440, 250 V
Temperature: 90 °C
Cross-section: 0.4 mm² - 4.7 mm²
... Application: The cable is used for general indoor and outdoor electrical instrument. Operating temperature: 90℃ Voltage rating: 250/440V Construction: CU/PVC/PVC,Flexible plain annealed copper ...
Shanghai Bluewin Wire & Cable Co., Ltd.
Nominal voltage: 10 kV
Temperature: -65 °C - 250 °C
... PEEK INSULATED WIRE, RADIATION RESISTANT, MULTISTRAND 0.35mm, LENGTH 10M Kapton Wires and Accessories Radiation Resistant Specifications Disruptive Voltage - > 10KV DC Voltage Rating - 4KV DC in vacuum Temperature Range - -65°C ...
Allectra.com
Nominal voltage: 0 kV - 132 kV
Cross-section: 240 mm² - 1,200 mm²
... conductor, XLPE insulated, Copper wire shield, PVC or PE Outer sheath EC 60840, IEC 62067, AS/NZS 1429.2… 1. Conductor 2. Conductor Screen 3. XLPE insulation 4. Insulation Screen 5. Semi-Conducting Tape 6. ...
Thinh Phat Cables Joint Stock Company
Nominal voltage: 300, 500 V
Temperature: -40 °C - 90 °C
... EN 50363-1. Cabling Insulated cores are cabled together. Overall screen Aluminium/polyester tape. Circuit protective conductor or drain wire Uninsulated tinned copper conductor of the same ...
... MV polymeric insulated single core cable connection pre-assembled with terminations MV pre-assembled connection made out of a single core polymeric cable with two terminations ...
Nominal voltage: 600 V - 1,000 V
Temperature: -40 °C - 90 °C
Cross-section: 1.5 mm² - 240 mm²
... POWERFLEX® RV-K cable is suitable for all types of low voltage industrial-type connections, in urban grids, building installations, etc. Its high flexibility makes the installation process substantially easier and, as a result, is particularly ...
Top Cable
Nominal voltage: 450, 750 V
... Flexible flat cables for lifts A07 VVH-F PVC flexible flat cables for lifts and moving equipments, cranes, hoists etc. Nominal tension 450 / 750 V. Cables are according to CEI 20-25-II - TAB ...
Nominal voltage: 600, 1,000, 1,500 V
Temperature: -50 °C - 115 °C
Cross-section: 120, 185, 240 mm²
... IBS Advanced Round Insulated Braided Conductor, Halogen Free are the ideal ready-to-install flexible wire replacement solution. Round IBS Advanced connect to the terminals of an electrical device without ...
... Overhead insulated cable This kind of products possess such characteristics as safe-use,weather-resistance,abrasion-resistance,high mechanical intensity,low line loss,etc.They can be used broadly in power network reconstruction ...
Qingdao Hanhe Cable Company
Temperature: 871 °C - 1,177 °C
... XACTPAK® mineral insulated, metal-sheathed cable from Watlow® is ideally suited to solve a wide variety of problem applications. The outer sheath can be made from any malleable metal in a wide range of diameters, containing ...
Temperature: -90 °C - 200 °C
... personalized layout and cable assembly • Coaxial cable • Triaxial cable • Video cable • Audio cable • Multiconductor cable • ...
Temperature: -25 °C - 80 °C
... layout and cable assembly Coaxial cable Triaxial cable Video cable Audio cable Multiconductor cable PTFE cable PUR ...
... layout and cable assembly Coaxial cable Triaxial cable Video cable Audio cable Multiconductor cable PTFE cable PUR ...
... Signal cable connect the sensor and the preamplifier and it can shield the sensor from electromagnetic interference. Features: Solid polytetrafluoroethylene insulated coaxial cables ...
... Coaxial cable is used for transmitting the AE signals, and as the cable connecting the preamplifier and the acquisition instrument, which has wideband of frequency and excellent noise suppression characteristics. Features: Radio ...
Temperature: -253 °C
Length: 2 m
... thin-diameter sensor cable is intended for measurements at cryogenic temperatures, down to 20 K, using a cryostat and our Kapton- or Teflon- insulated Hot Disk® or Hot Strip™ sensors. The sensor cable ...
Nominal voltage: 0 V - 1,000 V
Temperature: 70 °C - 1,200 °C
Cross-section: 0.1 mm² - 2.5 mm²
... Instrumentation Signal Cables minimize noise and signal interference, delivering clean signals in harsh environments and general manufacturing operations. These cables are designed for use in communication and instrumentation. Technical ...
... offers wide range of Mineral insulated (MI Cable), metal sheathed cable. - Thermocouple cables for measuring temperature. - RTD extension cables for use ...
... The GLS leads from hotset can be used at high temperature conditions of over 300 °C – when the use of copper cables is no longer possible. hotset offer a wide range of choice in cross-section, tracer thread and packaging. Also assembled ...
Length: 15 m
... EH2 Series tool cables are extremely durable. Unique double shell construction features high strength elastic fiber core covered by a molded resin. Connector is dual shell constructed from machined duralumin to assure ...
ASG Division of Jergens
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription