- Electricity - Electronics >
- Cable, Connector, Enclosure >
- Oil-resistant electrical cable
Oil-resistant electrical cables
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Nominal voltage: 1 kV - 1 kV
Temperature: -15 °C - 80 °C
... This plain copper unit is extra flexible, and designed according to NCF 32013/IEC 228 (Class 6). It is a special mini-polymer for robotics and features a tinned copper braid with optical coverage >85%. The single cores are stranded and wound by an anti-friction ...
Lapp Muller
Nominal voltage: 500, 300 V
Temperature: -40 °C - 80 °C
Cross-section: 0.5 mm² - 185 mm²
... VDE-registered largely oil resistant for selected torsion applications conditionally suitable for drag chains versatile use in many industries, particularly in machine and plant construction PVC ...
HELUKABEL
Temperature: -5 °C - 80 °C
... • Power supply for electrical applications and drives • Transmission of large electrical currents • Outer jacket valley-sealed extruded and high abrasion resistant • Oil- resistant • ...
TSUBAKI KABELSCHLEPP
Nominal voltage: 300 V - 1,000 V
Temperature: -55 °C - 145 °C
Cross-section: 1, 1.5 mm²
... Electron beam cross-linked cables for more demanding application requirements ÖLFLEX® HEAT 125 C MC - halogen free power and control cable with DNV GL certificate, special fire performance, IEC 60332-3, suitable for ...
Nominal voltage: 500, 300 V
Temperature: -50 °C - 90 °C
Cross-section: 0.75 mm² - 16 mm²
... D-VIERSEN · SABIX® A 260 PUR 12 x 1,5 mm² CE SABIX® A 260 PUR is a cold resistant, flexible control cable with numbered cores. This oil resistant cable is weather ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 2,000, 300, 500 V
Temperature: -50 °C - 90 °C
Cross-section: 0.5 mm² - 240 mm²
... control cable with numbered cores for continuous movement Marking for S 200 07741215: SAB BRÖCKSKES · D-VIERSEN · S 200 12 x 1,5 mm² CE High flex cable with numbered cores for continuous movement and uncritical ...
SAB BROECKSKES GMBH & Co. KG
Nominal voltage: 1,200, 1,500, 350 V
Temperature: -50 °C - 90 °C
Cross-section: 0.34, 0.5, 0.75, 0.25, 0.14 mm²
... paired TPE/PUR data cable with coloured cores and overall copper screen Marking for SD 200 C TP 07890350: SAB BRÖCKSKES · D-VIERSEN · SD 200 C TP 3 x 2 x 0,5 mm² CE SD 200 C TP is a continuously flexible paired TPE/PUR data cable ...
SAB BROECKSKES GMBH & Co. KG
Temperature: -40 °C - 105 °C
Cross-section: 8 mm²
... DescriptionPower cable with 8AWG (8 mm²) cross-section for battery or DC motor power supply. Ultra-flexible PVC sheath and high-temperature insulation (rated to 200°C). Rated current: 80 A. Sold by the metre for custom lengths.DetailsThe ...
Temperature: -40 °C - 105 °C
Cross-section: 50 mm²
... exceptional resistance to abrasion, oil and extreme temperatures (-40 to 105 °C). Maximum discharge current: 375A.ApplicationsMotor cable for powering brushless DC motors up to 20 kW.Battery cable for ...
Temperature: -35 °C - 85 °C
Length: 1, 3, 5, 8, 10 m
... ◆ Oil- resistant sheath for industrial environments. ◆ Specially prepared shielding improves anti-interference performance. ◆ The original imported Japanese HONDA connector, support PoCL power supply. ◆ It is ...
Odinvision
Temperature: -35 °C - 85 °C
Length: 1, 3, 5, 8, 10 m
... Bending resistance, drag resistance, oil resistance, cold resistance and flame retardant, suitable for tank chain application scenarios. ◆ Waterproof, oil- resistant, cold- resistant, ...
Odinvision
Temperature: 80 °C
Length: 1, 3, 5, 7 m
... . The smaller cable outer diameter enables sustained performance and reliability with small bend radii. Features ◆ Standard USB interface, high-speed transmission, support hot plugging, bending resistance, drag resistance, torsion ...
Odinvision
Temperature: -10 °C - 105 °C
Cross-section: 0.44, 0.75, 0.22 mm²
... general-purpose cableideal for extension leads. PVC is waterproof and is self-extinguishing, it has a high dielectric strength, good mechanical properties and provides resistance to chemicals, oil, hydrocarbons and abrasion. ...
Temperature: -10 °C - 105 °C
... PVC Cable (-10oC to 105oC) Conductors Tinned Cu, Screen Tinned Cu ...
Nominal voltage: 600 V
Temperature: -200 °C - 300 °C
... maglev field. Medical equipment MRI signal cables, detection of superconducting magnets and their feeder systems, superconducting solenoid signal cables, ultra-low temperature and high field insulated cables. Advantages ...
Nominal voltage: 500 V
Temperature: -5 °C - 70 °C
Cross-section: 0.75 mm²
... high voltage cable with number print and ground wire, 0,75mm², jacket gray RAL 7001, oil resistant number of cores: 3, 4, 5, 7, 12 ...
Metrofunk Kabel-Union
Nominal voltage: 500 V
Temperature: -5 °C - 70 °C
Cross-section: 1 mm²
... high voltage cable with number print and ground wire, 1,0mm², jacket gray RAL 7001, oil resistant number of cores: 3, 4, 5, 18 ...
Metrofunk Kabel-Union
Nominal voltage: 500 V
Temperature: -5 °C - 70 °C
Cross-section: 2.5 mm²
... high voltage cable with number print and ground wire, 2,5mm², jacket gray RAL 7001, oil resistant number of cores: - 3, 4, 5 ...
Metrofunk Kabel-Union
Nominal voltage: 300 V - 1,000 V
Temperature: -40 °C - 90 °C
Cross-section: 1.5 mm² - 240 mm²
IC AUTOMATION
Nominal voltage: 300, 1,000 V
Temperature: -40 °C - 80 °C
Cross-section: 0.08 mm² - 240 mm²
IC AUTOMATION
Nominal voltage: 1,000, 600 V
Temperature: -40 °C - 80 °C
IC AUTOMATION
Cross-section: 16 mm²
Length: 15 m - 30 m
... >Product code: GHT6001
Nominal voltage: 2, 3 kV
Temperature: -40 °C - 250 °C
Cross-section: 50 mm² - 800 mm²
... radius during installation 5× cable diameter (≤ 50 mm) and 6× cable diameter (> 50 mm); impact resistance AG2 (medium severity).
Top Cable
Length: 0 m - 1,000 m
... in two different versions: As a trunk cable for distances of up to 1000m between the switches As a spur cable, which can be used as a connecting cable for a device with a length of up to 200m. Spur ...
BizLink Robotic Solutions Germany GmbH
... Axon’ has designed tailor-made composite cables for 50 years. The company has integrated the manufacture of conductors (silver plated copper, tin plated copper, nickel plated copper,etc), the assembly, taping, shielding, and jacketing. ...
Axon Cable
Temperature: -40 °C - 90 °C
... IEC60332-3-25 Halogen-free, low smoke, low toxicity Acid and alkali resistance, ozone resistance Excellent oil resistance The cable has good resistance to high and low temperature ...
Zhaolong Interconnect
Nominal voltage: 300 V - 1,000 V
Temperature: -40 °C - 90 °C
Cross-section: 0.75 mm² - 240 mm²
... flexible cables with a high level of electromagnetic compatibility. The cables shielded with tinned copper braid are ideal for use in electromagnetically contaminated environments. The polyurethane (PUR) outer sheath ...
Brugg Kabel AG
Nominal voltage: 300 V - 1,000 V
Temperature: -70 °C - 450 °C
Cross-section: 0.08 mm² - 52.98 mm²
... Alpha Wire offers a variety of ribbon cable that facilitate easier routing and termination, taking up less space than wire harness bundles. These cables are designed ...
Nominal voltage: 300, 500 V
Temperature: -40 °C - 80 °C
Cross-section: 0.5 mm²
... rooms As a monitoring, measurement and control cable for industrial applications For flexible applications without compulsory guide PVC Flame-retardant, self-extinguishing Largely resistant to oils, ...
LÜTZE
Nominal voltage: 300, 450, 500, 750 V
Temperature: -30 °C - 80 °C
... flexible cables according to UL 758 Silicone sheathed flexible cables according to UL 758 Thermoplastic elastomer sheathed cables according to UL 758 PVC sheathed multi standard cables ...
Nominal voltage: 500, 450, 750, 300 V
Cross-section: 0.5 mm² - 240 mm²
... Excellent performance of oil resistance, solvent resistance. :450/750V 300/500V Voltage:Insulated wire: 450/750V or 300/500V :450/750V Control cable: 450/750V :0.6/1kV Power cable: 0.6/1kV Type ...
Shanghai Morn Electric Equipment Company
Nominal voltage: 600 V - 1,000 V
Temperature: -30 °C - 80 °C
... BC425 is a flexible cable that operates in working temperatures ranging from -30° C up to 80° C. Its testing voltage is 4000 V, while its nominal voltage is 600/1000 V. Cable is 300 m/min, while its acceleration rate ...
Brevetti Stendalto
Temperature: -25 °C - 75 °C
... unleaded outer sheath. This cable is flame retardant and resistant to mineral oils. This cable is used to connect the control centre to the centres of satellite equipment. Installed in ...
Nominal voltage: 600 V - 1,000 V
Temperature: 0 °C - 90 °C
Cross-section: 1.5 mm² - 35 mm²
... Short-circuit temperature tolerance: up to 250°C for 5 seconds.
Guangzhou Yuhong Technology CO., Ltd
Nominal voltage: 600 V
Temperature: 30 °C - 80 °C
Cross-section: 0.75 mm² - 325 mm²
... traveling cables are flexible and bendable, they are also tough enough to resist wear abrasion while maintaining a soft texture, making them the ideal product for use in outdoor wiring or with industrial machinery such as hoists and cranes. ...
Nominal voltage: 500, 2,000, 225 V
Temperature: -30 °C - 70 °C
... acc. to DIN VDE 0815 For information and signal transmission DIN VDE 0815 ; guideline 2014/35/EU RoHS 2011/65/EU EN 50575 ; EN 60332-1-2 ; EN 13501-6 class Eca min. bending radius installed - 10 x diameter min. bending radius moved - 10 ...
Nominal voltage: 300 V - 1,000 V
Temperature: -5 °C - 80 °C
... grey BayMotion® PVC-insulated power and control cable for connecting and linking electrical systems. The flexible connecting cables are suitable for permanent laying under normal loads and for occasional ...
Bayerische Kabelwerke
Nominal voltage: 750, 450 V
Temperature: -60 °C - 200 °C
Cross-section: 0.35 mm² - 1 mm²
... of cable installation temperature should not be less than 0'C • Cable bending radius: Cablebengding radius:non-armored cable a minimum of 6 times the cable diameter;Fluoride plastic ...
Nominal voltage: 300 V
Temperature: 75, 60, 90 °C
... weather resistance and oil resistance, and is suitable for application in outdoor or the case of exposure to oil pollution. 2. The cable is of high flame resistance, and can meet the FT2 requirements ...
Guangdong Rifeng Cable Company
Temperature: 70 °C
Length: 100, 200 m
... Power Cable, 3-Core Power Cable, Rvvp Double-Shielded Power Cable manufacturer / supplier in China, offering Rvvp 3*2.50mm&Sup2 * 160braid 3-Core Extruded Solid Double-Shielded Power Cable ...
Jiangsu Elesun Cable Co., Ltd.
... Elevator cable for the use of steel cable core, can be used for long-range suspension use occasions. the use of new oil- resistant special jacket, can be -15 degrees low temperature ...
Derulcable (Shanghai) Co., Ltd
Nominal voltage: 1,000 V
Temperature: -60 °C - 80 °C
... The cable SKD02-T is a system cable for connecting digital camera systems and was particularly developed to be used in hazardous areas. It meets the requirements for cables and wires according to DIN ...
SAMCON Prozessleittechnik
Nominal voltage: 300, 500 V
Temperature: -60 °C - 250 °C
... temperature resistant wires, high temperature heating wires, aging resistant wires and flame retardant wires; in the household appliance industry, it can be used in air conditioners, microwave ovens, ...
Nominal voltage: 300 V
Temperature: -40 °C - 150 °C
Cross-section: 0.22 mm² - 2.5 mm²
... Braid Shielded Halogen Free Multicore Class T4 ISO 6722 Class D STANDARD USE: Shielded cables with high abrasion resistance for cabling and electric systems inside vehicles. Operating temperature: -40°C ...
Elettronica Conduttori
Nominal voltage: 2,000 V
Cross-section: 16 mm² - 95 mm²
... its high flexibility and prevent the cable forming knots that may lead to damage to the conductor Welding cable is designed to transmit a high current between the welding transformer and the electrode. The cable ...
... Resilience™ Wind Turbine Tray Cable An innovation leader, Northwire offers Resilience™ Wind Turbine Tray Cables— the most flexible, rugged and technically advanced WTTC and low-voltage cables in the industry. Northwire ...
... Load bearing detecting cable Being used as connection wires of load-bearing devices,this kind of products are used for such works as logging,sampling and perforating of various oil and gas wells.They can also be used ...
Temperature: -40 °C - 80 °C
Length: 100 m
... °C
Cable length: 100 m
Connector material: Stainless steel
External
cable diameter: 5.9 mm (tolerance ±0.2 mm)
Enclosure/material characteristics: Flame UL FT-2;
Oil
resistant ...
Temperature: -40 °C - 80 °C
Length: 20 m
... steel connector for secure mounting
Technical specifications
- Material / enclosure: Flame rating UL FT-2; oil resistant
Temperature: -40 °C - 80 °C
Length: 50 m
... flexible installation)
... C.R.I. CÂBLES AUTOMATIQUES À PAROI FINE ISOLÉE EN PVC -40°C à +105° Les câbles automobiles en PVC à paroi fine résistants à la température à 105°C sont spécialement conçus pour les automobiles de nouvelle ...
Cross-section: 2.5, 4 mm²
... two-pole spiral cables are used to connect the intrinsically safe circuits of the SYMEGA series grounding monitoring systems with their peripherals (e.g. grounding clamps). The cable sheath is resistant ...
Cross-section: 4 mm²
... silicone-free steel core spiral cables from REMBE® offer superior mechanical strength. The steel core used can withstand continuous daily use and its cable sheath is extremely resistant to acids, alkalis, ...
Cross-section: 4, 2.5 mm²
... The single-pole copper spiral cables are characterised by their extremely high flexibility. The copper core used consists of 226 individual copper strands, which minimise the risk of cable breakage. Their cable ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.