- Detection - Measurement >
- Temperature and Humidity Measurements >
- Laboratory freezer temperature sensor
Laboratory freezer temperature sensors
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Temperature: -200 °C - 160 °C
Response time: 12 s
... or validation of sensors used in laboratory or bio freezers, walk-in refrigerators, autoclaves, ovens, stability test chambers, furnaces or incubators. Other applications might include IQ/ OQ/PQ qualification ...
Temperature: -50 °C - 550 °C
Probe diameter: 4 mm - 15 mm
... thermowell) and aluminum connection head where mounting a temperature transmitter with 4-20 mA or 0-10V output signal is possible. The measuring insert represents the replaceable element of the complete sensor which reduces ...
SIMEX Sp. z o.o.
Temperature: -40 °C - 1,700 °C
Probe diameter: 6, 4, 5 mm
... minimum sheath length: 15 mm any maximum sheath length thermowell spring protection against excessive cable bending The thermocouples SCT200 are designed for fitting directly into drilled hole or into process. SCT200 consists of thermometric resistor, ...
SIMEX Sp. z o.o.
Temperature: -50 °C - 400 °C
... out of stainless steel and connection cable. Insertion length, thermowell diameter, process connection thread, number of sensors, accuracy, cable length and insulation can be selected individually for the respective application. Application ...
SIMEX Sp. z o.o.
Temperature: -90 °C - 50 °C
Response time: 90 s
... The T10 temperature sensors are NTC (Negative Temperature Coefficient) thermistors, meaning that the resistance of the NTC decreases with increasing temperature. The T10 temperature ...
Temperature: -80 °C - 150 °C
... The T10 temperature sensors are NTC (Negative Temperature Coefficient) thermistors, meaning that the resistance of the NTC decreases with increasing temperature. The T10 temperature ...
Temperature: -100 °C - 200 °C
... Pt100 Smart- Sensor (-100°C to +200°C) for many applications, such as -80°C freezers. The Smart- Sensor technology allows for on-board calibration details and features analog/digital converter to simplify ...
Temperature: -80 °C - 150 °C
... The SD051 and SD051(EP) temperature probe is designed for monitoring temperature in refrigerators, freezers and cold storage facilities. SD051: for service to -25°C SD051(EP): for ...
Temperature: -70 °C - 250 °C
... The Hygienic Quick Connect temperature probes incorporates an M12 lockable connector and a hygienic tri-clover flange for connection into a process using standard hygienic clamps and gaskets. The M12 connector allows ...
Temperature: -50 °C - 180 °C
Probe diameter: 6 mm
Response time: 10 s
... data Tolerance :Class B: △t=±(0.30 + 0.005 |t| )℃(standard) Class A: △t=±(0.15 + 0.002 |t| )℃ Transmitter: Integrated temperature transmitter 24VDC, 4~20mA, 2-wire Transmitter errors: standard ±0.5% . ±0.2% is optional. Response ...
Temperature: -40 °C - 125 °C
Probe diameter: 3 mm
Response time: 10 s - 300 s
... different designs, specifications and cables to meet varied demands. The range includes products for: temperature profiling; pipework monitoring; fridge and freezer monitoring; for use in composting and even armoured ...
Temperature: -40 °C - 200 °C
... transmitter with an internal temperature sensor to measure ambient temperature and a flying lead temperature with 1.5m cable. The flying lead cable is only 1mm thick so is ideal for passing ...
Temperature: -40 °C - 100 °C
... similar appliances. Thus measuring the food temperature, not the ambient temperature. The probe incorporates a one metre PUR/PVC lead and compatible three-pin Binder connector. Probe temperature range ...