- Electricity - Electronics >
- Switch and Relay >
- Magnetic circuit breaker
Magnetic circuit breakers
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
Primary current: 0.5 A - 125 A
VAC: 230 V - 500 V
VDC: 12 V - 230 V
... event of failures due to overloads, short circuits and for the life-saving differential versions even in the case of dispersed currents. The offer includes: • Thermal magnetic circuit breakers; • ...
Primary current: 0 A - 30 A
VAC: 120 V - 240 V
VDC: 32 V
... contacts and minimizes arcing. SNAPAK® circuit protectors are UL Recognized as supplementary protectors per UL STD. 1077, CSA Certified as supplementary protectors per CSA STD. C22.2 No. 235, TUV Approved as circuit breakers ...
Sensata Technologies
Primary current: 0.2 A - 70 A
VAC: 400, 250, 415, 277 V
VDC: 80 V
... IALHR, IULHR, and IELHR Series. Rail-Mount Magnetic circuit protectors offer the advantages of quick and easy mounting or removal, resulting in efficient and economical wiring while conserving space. These circuit ...
Sensata Technologies
Primary current: 5,000 A - 10,000 A
VAC: 240 V
... Our lowest depth breaker family, the Airpax LEX/LUX Series hydraulic magnetic circuit breaker allows increased density in datacenter rack power distribution units while leaving more space ...
Sensata Technologies
Primary current: 630 A - 800 A
VAC: 15 kV - 38 kV
Rating: 12.5 A - 20 A
... • IEC 62271, ANSI/IEEE Std C37.60, NEMA • ISO 9001, KEMA, CESI, CE, TUV, UL, ASTA • Seismic design, ETGI-1.020, IEEE Std 693, NCh2369 • Structural design, ASTM A325, ANSI/AISC 360, AWS D1.1 • High altitude correction per IEC 62271 & IEEE C37, ~ 5000m • ...
Primary current: 10,000 A - 100,000 A
VAC: 400 V
Rating: 0.3 A - 100 A
... •Type of protection: Magnetic and thermal •Type of control: Push button •Certified UL Type E: No •Order code - SM1P0400 •Weight [g] - 295 •Qty. per package - 10 •Multiple qty. of packs per order - 10 •Package dimensions [mm] - ...
LOVATO ELECTRIC
Primary current: 12.5 A - 800 A
VAC: 230 V - 500 V
VDC: 125 V - 250 V
... Adjustable Thermal and Fixed Magnetic Trips : Frame Size: 125~800AF(3Pole & 4Pole) Rated Current: 12.5A~400A adjustable Rated Current: 630A~800A Fixed Breaking Capacity (IEC 60947-2 AC380V Icu) : 65kA ...
Primary current: 3,000, 4,000, 6,000 A
VDC: 750 V - 1,800 V
... Entec's DC High-Speed Circuit Breaker (HSCB) symbolizes our advanced technology in DC interrupting. Entec's HSCB(EDB-09 and EDB-18) is used to manage DC Power Feeding line and interrupts the fault current. EDB-09 has ...
Primary current: 16, 25, 40 A
VAC: 400, 415 V
... ELECTRO- MAGNETIC RCCB RNR1-40 ( from 1 to 40 A, up to 10kA ) meets any requirement for protection against residual current for all household, commercial and any low-voltage distribution systems. Saving 50% of space usage, ...
WENZHOU RENA ELECTRIC CO.,LTD
Primary current: 4,000, 2,500 A
VDC: 1,000 V
... ejection in its operation, AFB® circuit breaker applies principle of power circuit interruption in vacuum. As a result, AFB® circuit breaker requires half the size of ...
Primary current: 630, 1,250 A
VAC: 12 kV
... 12M series outdoor H.V. permanent magnetic vacuum circuit breaker is used in tri-phase electric system of AC 50 Hz, rated voltage 12kV. It is suitable for breaking, closing load current, overload current ...
Primary current: 5 mA - 300 mA
... Rowe Hankins Ltd. Residual Circuit Breaker Overload products (RCBOs) have two main functions: Firstly, to help to measure AC residual current; Second, to trip whenever they detect a fault. The RCBOs are available ...
Primary current: 0 A - 1,600 A
VAC: 550, 800 V
... of a circuit breaker provides the feature of inverse time-delay, while the magnetic release is the instantaneous operation as shown on table 2(distribution circuit breaker) ...
Andeli Group Company
Primary current: 6,000 A
VAC: 230 V
Rating: 25 A
... - Tripping curve: B, C B - The maximum current release breaks between 3 and 5 In; used to protect long circuits and generators С - The maximum current release breaks between 5 and 10 In; used to protect main power supply cables and ...
Elmark
Primary current: 40 mA
VDC: 19 V - 30 V
Rating: 30 A
... Input voltage required to switch on the outputs, typ. - 19 Vdc Output data Output current (sum of all outputs) - 30 A Turn-on delay of outputs - 750 ms Overview Dimensions (WxHxD) - 52 mm x 124 mm x 130 mm Weight per unit (excl. packaging) ...
PULS GmbH
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group