- Electricity - Electronics >
- Switch and Relay >
- Molded case circuit breaker
Molded case circuit breakers
Primary current: 6 A - 1,250 A
VAC: 500, 800, 690 V
... up to 1250A, functions as non frequently switching in a circuit and non frequently starting a motor. MCCB is mainly used in a building power distribution system, protection against short-circuit, overload ...
The over-view below shows the full range of SCAMEs distribution assemblies. With their compact size, robust construction and protection degree from IP44 to IP66, they meet the most varied power distribution requirements in factories, ...
Primary current: 1 A - 10 A
VDC: 24 V
DISJONCTEUR ELECTRONIQUE/DC24V/CONTRE LES SURINTENSITE/CONTRE LES COURTS-CIRCUITS/MODULAIRE/A BOITIER MOULE/MONTAGE RAIL DIN/COURANT NOMINAUX FIXES/DE 1 A 2 CANAUX PAR MODULES
E-T-A
Primary current: 20 A - 1,600 A
VAC: 0 V - 1,100 V
VDC: 900 V
TemBreak 2 is the Ultimate Safety Breaker. It has specifications which exceed international standards for safety. Direct opening action - recommended by IEC standards for machinery safety - is a feature of most models. A ...
Terasaki (Europe) Circuit Breaker
Primary current: 6 A
VAC: 230 V
Description Miniature circuit breakers series ETIMAT 6 are high quality devices, produced in EU, with following technical characteristics: Rated short-circuit capacity: 6.000 A Number ...
ETI
Primary current: 800 A - 1,600 A
VAC: 415 V
TemBreak2 The Ultimate Safety Breaker - Catalogue of products for sale in Japan, Asia and Australia. These next-generation breakers emphasize safety with suitability for isolation and direct opening ...
Terasaki Electric Circuit Breaker
Primary current: 160 A - 250 A
Moulded Case Circuit Breakers New TemBreak2 Catalogue No. ’12-I64E 160A and 250A frames of new compact breakers can provide saving space and saving money to you.
Terasaki Electric Ltd
Primary current: 0.1 A - 50 A
VAC: 415, 250, 240, 80, 32 V
VDC: 80, 65 V
... Vibrations: IEC 68-2-6 Mil-std 68-2-3 Umidity: IEC 68-2-6 Mil-std 68-2-3 Note Single or multipole small size circuit breaker, handle, rocker or sealed mount toogle, also available with ...
COMESTERO SISTEMI
Primary current: 125, 250 A
VDC: 500 V
... 400, size: 320A, 400A • Tested: ultimate short circuit breaking capacity Icu of 25kA according to IEC 60947-2, NCM1-DC250 PV 2P DC500V/4P DC1000V specialized in Molded Case Circuit ...
SHANGHAI ANSON ELECTRIC TECHNOLOGY CO.,LTD
VAC: 660, 380, 400, 690 V
VDC: 250 V
... protecting the circuit and electrical equipment against overload and short circuit. 3. It complies with standard of IEC60947-2. Classification: 1. Installation way: Mounted vertically, Horizontal ...
Primary current: 0 A - 1,600 A
VAC: 550, 800 V
... of a circuit breaker provides the feature of inverse time-delay, while the magnetic release is the instantaneous operation as shown on table 2(distribution circuit breaker) ...
Primary current: 63 A - 800 A
VAC: 230 V - 400 V
... possibility for mounting to lengthening terminal • Plastic elements not keeping the burning material nylon PA66 box permitivity strength: >16MV/m • Abnormal heating wear resistance and fire of the outer ...
Elmark
Primary current: 125 A - 400 A
VDC: 1,000, 1,250, 1,500 V
... plastic case circuit breakers for photovoltaics—parameters.the battery systems and energy storage systems,with over load protection and short. Product Benefits High Breaking Capacity, ...
Primary current: 125 A
VDC: 1,000 V
BD-125 DC mold-case circuit breaker for DC application 1000V 125A
Zhejiang Benyi Electrical Co.,ltd.
Primary current: 2 A - 63 A
VAC: 230, 240, 415, 400 V
VDC: 48 V
WERNER'S 50 series miniature circuit breakers provide the customer a comprehensive efficient, reliable protection of equipments, cables and installations in buildings for over load and short circuit ...
Primary current: 160, 200, 225, 250 A
VAC: 380, 415 V
Federal Elektrik
Primary current: 500 A - 630 A
VAC: 690 V
... Ui:690V Current:500.600.630A Pole: 3P 4P Breaking Capacity: Icu: 220V/ 35kA (sym) 380V/ 25kA (sym) 440V/ 22kA (sym) Ics = 50% Icu Accessories: AL.AUX.SHT.UVT.EH630N(IP30.IP52).TC630N.
Shihlin Electric & Engineering Corporation
Primary current: 63 A
... leakage circuit breaker is used for the protection, against electrical leakage in the circuit of 50/60Hz, rated voltage 1- phase 240V, 3 phase - 400V, rated current up to 63A.When somebody ...
Primary current: 0.16 A - 100 A
Motor Protection Circuit Breakers with special features: Find four device sizes with a short-circuit breaking capacity of up to 100kA and tripping ranges up to 100A. Among other things, ...
Primary current: 0 A - 0.05 A
VDC: 0 V - 10 V
Our most popular alarm trip, thousands in operation Universal plant standard, no need to stock different alarm trips Pushbuttons- and PC-programmable with FREE software and cable Customizable display shows process status/diagnostics 20-bit ...
Moore Industries
Primary current: 12.5 A - 160 A
VAC: 690, 400 V
RDM6 series Moulded case circuit breaker, mainly applied to the circuit of AC 50Hz, rated insulation voltage 690V(control loop circuit voltage 400V), ...
PEOPLE ELE. APPLIANCE GROUP CO., LTD.
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining