Primary current: 30 mA - 125,000 mA
... 690VAC. The Uimp rated impulse withstand voltage is 8kV. The pollution degree is 3. It can be mounted on 35 mm symmetrical DIN rail. The width in 9mm pitches is 9. The dimensions are (W) 189mm x (H) 118mm ...
Schneider Electric - Electrical Distribution

Primary current: 0.1 A - 32 A
... protect Max. load, AC-3 [kW] 15 kW Packing format Multi pack Product description Circuit Breaker Product group Contactors and motor starters Product name Circuit breaker Quantity ...
Danfoss Industrial Automation

Primary current: 32 A
VDC: 400 V
... protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics ...

Primary current: 0.5 A - 100 A
VAC: 240 V - 415 V
... other components from the rail. Dual-position plastic clips also help with the simple installation and replacement of miniature circuit breakers on the DIN rail. ...

Primary current: 10 A - 40 A
... fires and protects people, property and assets AFDD+ All-in-one device: Arc Fault Protection + Short Circuit & overcurrent protection (MCB) + Earth fault current protection (RCCB) Tripping ...

Primary current: 1 A - 63 A
GSB2 series Miniature Circuit Breaker is mainly used in AC 50Hz or 60Hz circuit with rated operational voltage up to AC 415V, with operational current up to 63A. It can be attached ...

Primary current: 0.5 A - 63 A
VAC: 480, 240, 277 V
... Application Information Circuit Voltage The Bulletin 1489-M circuit breakers are rated by voltage class.Applications should not exceed the listed voltage and current range. Circuit ...
Allen Bradley

Primary current: 3,000 A
VAC: 0 V - 277 V
VDC: 12 V - 60 V
... installation. In the event of an overload or short-circuit, miniature circuit breakers safely cut off the connected circuit and reliably protect electrical installations ...

Primary current: 6 A - 63 A
VAC: 240, 415 V
The motorized circuit breakers of the MT Series can be associated remotely. They protect against short-circuits and overloads, but are also used as a circuit breaker. ...

Primary current: 0.03 A - 1 A
VAC: 110 V - 400 V
Modular residual current relays RD21 series Modular residual current relay. RD23 series Modular residual current relay with leakage current indicator.

Primary current: 80 A - 125 A
VAC: 230 V - 400 V
Circuit breakers PR121 - PR122 - PR123 - PR124 series 1- to 4-pole circuit breakers

... magnetic circuit protection. Mounting - These circuit protectors are designed to mount on standard 35mm DIN rails, such as 35x7.5 or 35x15 per DIN ...

Primary current: 6 A
VDC: 230 V
... with their product range. This begins with their identical profile which adds to the streamlined and co-ordinated look of the installation. These new products feature a rated short-circuit capacity ...
ETI

Primary current: 40,000 A
VAC: 230, 400 V
Features: Status indication. MCB specially designed for Surge Arrester. It can cut the leakage current to 3A. Therefore prevent possible fire hazzard caused by degenerated SPD. Special MCB designed to protect the SPD.

Primary current: 1 A - 63 A
VAC: 400, 230, 415 V
VDC: 10 V - 10 V
DZ47 AC MCB circuit breaker series is used in lighting distribution system or motor distribution system for protecting overload and short-circuit condition. The product is light in weightreliable ...

VAC: 230 V
Rating: 2 A - 32 A
DIGITAL ELECTRIC

Primary current: 2 A - 125 A
VAC: 12 V - 400 V
Rating: 1 A - 63 A
DIGITAL ELECTRIC

Primary current: 15,000, 20,000 A
VAC: 320 V
DIGITAL ELECTRIC

Primary current: 1 A - 63 A
VAC: max 400.0 V
VDC: max 125.0 V
BSB7 series hydraulic circuit breakers are suitable for distribution lines with rated AC working voltage up to 400V, single-pole DC voltage up to 125V, and bipolar voltage up to 250V, and rated current ...

Primary current: 1 A - 63 A
VAC: 230, 400 V
VDC: 80, 125, 175 V
BSB7 series hydraulic circuit breakers are suitable for distribution lines with rated AC working voltage up to 400V, single-pole DC voltage up to 125V, and bipolar voltage up to 250V, and rated current ...

Primary current: 0 A - 63 A
VAC: 230, 400 V
COMESTERO SISTEMI

Primary current: 0.1 A - 63 A
VAC: 400, 480 V
Single or multipole mid range compact circuit breaker, 35 mm DIN rail mounting, large number of built-in options
COMESTERO SISTEMI

Primary current: 0.1 A - 100 A
VAC: 600, 250, 400 V
VDC: 125 V
Single or multipole circuit breaker, mid to large current range in a compact E-frame case,large number of built-in options Options Integrated auxiliary switches, high-inrush (8 x In, 15 x In, 22 ...
COMESTERO SISTEMI

Primary current: 15, 40, 45 A
VDC: 10 V - 30 V
... PROFINET interface for supplying the CAPAROC circuit breaker system with 12 or 24 V DC. Additional system interface for communication with the power supply. For DIN rail ...

Primary current: 1 A - 63 A
VAC: 240, 415 V
... overload and short circuit protection, applies to a circuit of AC 50Hz,rated voltage 230/400V, rated current up to 63A. Usually it functions as un frequently switching. In addition, it can be also used ...

Primary current: 10 A - 63 A
VAC: 230 V
... short circuit, poor contact of connector, arc caused by house electrical apparatus fault).Then it triggers tripping unit to cut off the power supply to prevent electrical fire. AFDD is used together with leakage circuit ...

Primary current: 0 A - 123 A
The new range of DIN modular device incorporate an all new design of Miniature Circuit Breaker (MCB) which includes dual connection terminals at the bottom of the breaker, ...

Primary current: 0 A - 63 A
EQUES®CrossBoard. Miniature circuit breaker directly on the CrossBoard® MCBs directly on the CrossBoard®1-pole adapter for mounting miniature circuit breakers from various ...

Primary current: 10 A - 250 A
VAC: 240 V - 690 V
VDC: 125, 250 V
Circuit breakers protect human lives, buildings and properties against risks of electrical short circuit. Since our founding, TERASAKI has left competitors far behind in the field of ...

Primary current: 0.5 A - 63 A
VAC: 480, 230, 400 V
VDC: 48, 96 V
... Bulletin 1489-M Thermal-magnetic Circuit Breakers are UL 489 Listed for branch circuit protection in the United States and Canada, and they are certified as Miniature Circuit ...
Allen-Bradley

Primary current: 1 A - 10 A
VDC: 24 V
DISJONCTEUR ELECTRONIQUE/DC24V/CONTRE LES SURINTENSITE/CONTRE LES COURTS-CIRCUITS/MODULAIRE/A BOITIER MOULE/MONTAGE RAIL DIN/COURANT NOMINAUX FIXES/DE 1 A 2 CANAUX PAR MODULES
E-T-A

Primary current: 2 A - 10 A
VDC: 24 V
General Data Nominal input voltage 24 Vdc Output channels: 2 / 4 / 8 Tripping current: 2 ‑ 10 A Thermomagnetic characteristic Operational temperature ‑25° C ... +70° C Protection index IP 20 Efficiency: typ. 99 % Advantages Adjustable ...
Block Transformatoren-Elektronik
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining