Type WDG is a drum type de-energized tap changer. It is often designed by the combination of one single-phase and one two-phase tap changers. These two tap changers are to be installed in the clearance between the three winding in one transformer, which ...
HUAMING POWER EQUIPMENT CO., LTD.
... Type WSL De-Energized Tap Changer (herein referred as tap changer) is of in-tank structure and without separate oil compartment. It is mounted to transformer tank by a tap changer head ange. By the operation method, tap changer can be divided into ...
HUAMING POWER EQUIPMENT CO., LTD.
Intensity: 63, 30 A
Load voltage: 30, 20 kV
... Direct drive operation, from side wall of tank, or cover of Transformer. Fixing on tank, or cover of Transformer by bolting of the main bracket (hole dia 20 mm on tank or cover of Transformer) 6 available heights for the main bracket (L=70, L=100, ...
ASP Company
Intensity: 63 A
Load voltage: 30 kV
... Direct drive operation, from side wall of tank, or cover of Transformer. Fixing on tank, or cover of Transformer by bolting of the main bracket (hole dia 20 mm on tank or cover of Transformer) 6 available heights for the main bracket (L=70, L=100, ...
ASP Company
Intensity: 175, 30, 63 A
Load voltage: 30, 20 kV
... Cable operation, from side wall of tank, or cover of Transformer Fixing on tank, or cover, or active part of Transformer : by bolting of control device (hole dia 27 mm to provide in tank or cover) by bolting of main board on active part, or tank, ...
ASP Company
Intensity: 30, 63, 175 A
Load voltage: 30, 20 kV
... Cable operation, from side wall of tank, or cover of Transformer Fixing on tank, or cover, or active part of Transformer : by bolting of control device (hole dia 27 mm to provide in tank or cover) by bolting of main board on active part, or tank, ...
ASP Company
Intensity: 150, 63, 30 A
Load voltage: 45, 20 kV
... Direct drive operation, from side wall of tank, or cover of Transformer Fixing on tank, or cover of Transformer : by bolting of main bracket on tank, cover or active part of Transformer by bolting of additional support (metallic bracket or insulating ...
ASP Company
Intensity: 150 A
Load voltage: 45 kV
... Direct drive operation, from side wall of tank, or cover of Transformer Fixing on tank, or cover of Transformer : by bolting of the main bracket (hole dia 27 mm on tank or cover of Transformer) by bolting of additional support (metallic bracket or ...
ASP Company
Intensity: 150 A
Load voltage: 52 kV
... Direct drive operation, from side wall of tank, or cover of Transformer Fixing on tank, or cover of Transformer : by bolting of the main bracket (hole dia 27 mm on tank or cover of Transformer) by bolting of additional support (metallic bracket or ...
ASP Company
Intensity: 150 A
Load voltage: 52 kV
... Direct drive operation, from side wall of tank, or cover of Transformer Fixing on tank, or cover of Transformer : by bolting of the main bracket (hole dia 27 mm on tank or cover of Transformer) by bolting of additional support (metallic bracket or ...
ASP Company
Intensity: 400 A
Load voltage: 100 kV
... Direct drive or through coupling operation, from side wall of tank, or active part of Transformer Remote controls at man’s height are available, for shaft crossing on top or bottom of tank, or on cover of Transformer Fixing on tank, or cover of Transformer ...
ASP Company
Intensity: 400 A
Load voltage: 100 kV
... Direct drive or through coupling operation, from side wall of tank, or active part of Transformer Remote controls at man’s height are available, for shaft crossing on top or bottom of tank, or on cover of Transformer Fixing on tank, or cover of Transformer ...
ASP Company