Air flow: 500 m³/h - 1,870 m³/h
Noise level: 52 dB - 63 dB
... radial fans on KryosROOF provide high flow rates and heads to ensure the correct airflow within the cabinet. In addition, there is a high efficiency version with EC fans and an active control probe, ...

Air flow: 300 m³/h - 500 m³/h
... Time-saving installation and mat exchange Roof filter fans find use in enclosures and housings, from which warm air has to be diverted to lower the internal temperature. These low-noise roof filter fans ...

Air flow: 1,000 m³/h - 35,000 m³/h
The Extractair® is a centrifugal fan that allows the evacuation of polluted air to the workstations. Installed on the roof and connected to piping networks, it is used to: - Cleaning and air renewal; - Cooling ...

Air flow: 100 m³/h - 450 m³/h
Roof Extract Fan Low Pressure Produced completely by injection moulding. Polypropylene housing and plinth resistant to UV rays. High-performance polypropylene impeller with forward curved blades, statically and dynamically ...
PLASTIFER

Air flow: 500 m³/h - 1,600 m³/h
Roof Extract Fan Low Pressure Produced completely by injection moulding. Polypropylene housing and plinth resistant to UV rays with dual positions. High-performance polypropylene impeller with forward curved blades, ...
PLASTIFER

Air flow: 900 m³/h - 2,200 m³/h
Roof Extract Fan Low Pressure Produced completely by injection moulding. Polypropylene housing and plinth resistant to UV rays with dual positions. High-performance polypropylene impeller with forward curved blades, ...
PLASTIFER

Air flow: 520 m³/h - 3,600 m³/h
Noise level: 54 dB - 64 dB
The STORM series roof fan is used to remove used air from a room with dust content not exceeding 0.3 g / m³. It is intended for external use on building roofs. Thanks to the specially designed fan impeller ...

Air flow: 600 m³/h - 18,900 m³/h
The ET extraction roof top exhast fan is used to aspirate considerable volumes of air with low pressures. The dimensions and its modest weight facilitate its assembly directly on roofs, both with free aspiration and ...

Air flow: 21,000, 39,800 m³/h
... premium propeller fan group in stainless steel AISI-304, blind overpressure and IE2 three-phase motor with IP-55 protection. The tether anchors on the roof are designed to suit all kinds of inclination. The supply ...

"Highly efficient ventilation duct The ET ventilation duct is normally used to extract large volumes of air with low pressures. The dimensions and light weight facilitate assembly directly on the roof, whether with free extraction or ...

Air flow: 0 m³/h - 15,000 m³/h
EC Roof fans (Type: DV/S...G / DVE/S...G / DVW/S...G) Properties flow rates up to 15,000 m³/h size: 310 - 710 mm (impeller diameter) vertical outlet highly efficient EC technology backward curved impellers mounted ...

Air flow: 0 m³/h - 15,000 m³/h
Roof fans (Type: DH, DHE) Properties flow rates up to 15,000 m³/h size: 190 - 630 mm (impeller diameter) horizontal outlet backward curved impellers solid weatherproof casing easy to install Casing The casing ...

Air flow: 0 m³/h - 36,000 m³/h
Roof fans with IEC standard motor (Type: DVNF/S, DVN/S) Properties flow rates up to 36,000 m³/h size: 310 - 900 mm (impeller diameter) vertical outlet IEC standard motors as drive suitable for higher conveying ...

Air flow: 1,130, 770, 470, 290 m³/h
Vertical discharge centrifugal roof fan with isolation switch on the casing. Casing and base bplate made of galvanised steel. The fans are factory-wired with the isolation switch. The base plate of casing ...

Air flow: 490 m³/h - 19,100 m³/h
... and UV. also ensuring unit weighs less. The motor Is outside of the at stream (except VD.. 180) beneath a GRP-cowl. A cooling fan and vents in the motor cover ensure a recooling through the atmospheric air. Starting from ...

Air flow: 3,100 m³/h - 34,550 m³/h
Robust, corrosion and weather resistant construction. Base plate made of galvanised steel. Cowl and protection grille made of galvanised steel, nominal sizes 225 - 400 mm made of aluminium. Nominal size 710mm with ccwl made of glass fibre ...

Air flow: 550, 850, 800 m³/h
... These units can be provided with an exhaust filter for either convection cooling or forced air-cooling in combination with a fan. The "T" series offers a metal structure.
Fandis

Plastim presents PFF5500 ventilation roof fans. They provide an air flow rate of 560m³/h. They have dimensions of 230V 50-60Hz. Power consumption is 58/75W, and current consumption is 0.26/0.34A. PFF5500 can handle operating ...

Air flow: 27,000 m³/h
Velone – Smoke exhaust roof fans CE marking-compliant. F400 Class (400 °C – 120 min) in accordance with EN 12101-3. Airflow range up to 27,000 m3/h. Compact to protect against impacts and weather. ALL-IN-ONE option (built-in ...

Air flow: 1,600 m³/h - 25,800 m³/h
... ow, consumption, sound level, size, etc. Standard fan is prepared for extract purposes, however it exists the option to order intake roof units. Applications: In places where a fl at shape of the roof fan ...

Air flow: 1,000 m³/h - 24,000 m³/h
High performance roof fan with backWard curved impeller allowing moderate consumption. The motor is not in contact with extracted gases, therefore the fan is suitable for extraction of harmful and/ or ...

Air flow: 600 m³/h - 1,500 m³/h

Air flow: 600 m³/h - 860 m³/h

Air flow: 600 m³/h

Air flow: 1.97, 2.69, 3.6 m³/h
... connection 2 separate mains connections (230 V, 50 Hz) needed for fan and control unit. Mains connections 3 x 1.5 mm2 each, type NYM-J / NYM-O. 6-core shielded control cable between control and fan.
MAICO Ventilatoren

Air flow: 4,400 m³/h - 8,250 m³/h
... steel structure with an epoxy powder finish A statically balanced axial electric fan with a protective supporting grill Thermal protection to prevent overheating Output fans

... and outlet deflector The Woods Induction Thrust range is the super low profile car park ventilation and fire safety fan. Induction fans use a centrifugal blower with factory fitted inlet bell mouth & ...
FläktGroup

Air flow: 1,250 m³/h - 95,000 m³/h
Use : Continuously ventilates spaces with clean air below 60°C or extracts smoke. For use in commercial, industrial and healthcare facilities. Designed for outdoor installation on all types of roof or ducts. Description : Smoke ...

Air flow: 100 m³/h
ZHEJIANG SHANGFENG SPECIAL BL OWER INDUSTRIAL COMP

Air flow: 3,800 m³/h - 90,000 m³/h
... GA211-2009 "fire smoke exhaust fan high temperature resistance test method”,test certificate. ※ The fan impeller can be made by of carbon steel mold, welding forming, dynamic balance can be G2.5 leve ...
Zhejiang Pengxiang Hvac Equipment Co., Ltd.

Air flow: 1,500 m³/h - 190,000 m³/h
VENCO Axial fans are used in car parks, subways, refrigeration and mining ventilation projects besides general ventilation applications. They are suitable for industrial and commercial applications. The best matching ...
Venco Havalandirma

Air flow: 1,993 m³/h - 46,141 m³/h
Specification:3.55#~10# Power:0.09~7.5KW Flow rate:1993~46141m³/h
Zhongshan Yongning Ventilation System Manufacturing Co., Ltd.

Air flow: 0 m³/h - 2,200 m³/h
Horizontal compact jet roof extract unit Compact design with net protection Complete with terminal box Available in 3 models: 220, 225, 280 Made of galvanized steel, stamped steel plate cover Flow rates up to 2200 m3 / h

Air flow: 1,300 m³/h - 15,000 m³/h
... 20 °C, maximum + 80 °C (+ 150°C with cooling fan !!). CONSTRUCTION FEATURES The group is formed by a hight capacity centrifugal fan wheel ,which is statically and dynamically balanced .The centrifugal ...
EUROVENTILATORI INTERNATIONAL
Your suggestions for improvement:
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group
Please specify:
Help us improve:
remaining