- Hydraulics - Pneumatics >
- Valve >
- Shuttle check valve
Shuttle check valves
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
{{product.productLabel}} {{product.model}}
{{#if product.featureValues}}{{product.productPrice.formattedPrice}} {{#if product.productPrice.priceType === "PRICE_RANGE" }} - {{product.productPrice.formattedPriceMax}} {{/if}}
{{#each product.specData:i}}
{{name}}: {{value}}
{{#i!=(product.specData.length-1)}}
{{/end}}
{{/each}}
{{{product.idpText}}}
DN: 9.525 mm
Pressure: 3,000 psi - 5,400 psi
Flow rate: 3.7 us gal/min - 5 us gal/min
... This valve combines the function of a reverse flow pressure relief valve in parallel with that of a check valve with free flow in the forward direction — all in one easy-to-install insert. ...
DN: 0.375 in
Pressure: 3,000 psi - 5,400 psi
Flow rate: 3.6 us gal/min - 5 us gal/min
... This valve combines the function of a reverse flow pressure relief valve in parallel with that of a check valve with free flow in the forward direction — all in one easy-to-install insert. ...
DN: 0.281 mm
Pressure: 625 bar - 6,600 bar
Flow rate: 0.9 us gal/min - 5.9 us gal/min
... This valve combines the function of a reverse flow pressure relief valve in parallel with that of a check valve with free flow in the forward direction – all into one easy-to-install ...
DN: 6 mm - 18 mm
Pressure: 315, 700, 500 bar
Temperature: -40 °C - 80 °C
... The shuttle valve type WV is integrated in a T-fitting for pipe connection. The type WVC is a screw-in valve. The shuttle valves can withstand pressures up to 700 bar ...
DN: 0.25 mm
Pressure: 21 MPa
Flow rate: 20 l/min
... These valves are used to open a line from the inlet port with the higher pressure of the two to the outlet port. ...
Daikin PMC
DN: 0.125 in - 1 in
Pressure: 0.5 bar - 12 bar
Temperature: -10 °C - 120 °C
... Controllable valves for compressed air control For regulating the compressed air supply to consumers ...
Pressure: 0 bar - 250 bar
Temperature: -30 °C - 120 °C
Flow rate: 20 l/min
... Leak-free closing, suitable for fast cycling with long life High flow capacity In the standard version, the valve is zinc-coated for 240 h protection acc. to ISO 9227 ...
ARGO-HYTOS
Pressure: 1,000 psi
... Featuring 1/8 ports, these NPT shuttle valves come in a gold colour and have a force of about 1/2 psig. At most these devices can manage 300 of air per 1000 hyd. These shuttle valves ...
Pressure: 250 psi
Temperature: 32 °F - 230 °F
... Shuttle Valve, #10-32 Male Outlet, #10-32 Female Inlets Notes Shuttle valves should not be used as a pressure selector. Flow from "A" to "C" or "B " to ...
Pressure: 2 bar - 10 bar
Temperature: -10 °C - 70 °C
... It is used when two valves hâve to opéra te the same equipment. The signal, no matter from which of the two valves it cornes, is re-ceived by the shuttle valve and trasmitted to the device ...
DN: 4, 5.5, 3.2 mm
Pressure: -0.9 bar - 10 bar
Temperature: -10 °C - 70 °C
... Medium Filtered, oil-free and dried compressed air according to ISO 8573-1:2010, Class 7:2:4, instrument air, free of aggressive additives. Alternatively the pressure dew point must be at least 10°C below lowest occurring ambient temperature. Materials Body: ...
DN: 0.125 in - 0.5 in
Pressure: 0 bar - 12 bar
Temperature: -20 °C - 80 °C
... Complementary valves are very important components of the pneumatic circuits. This group includes the: - SHUTTLE VALVES: these valves are used when there is the necessity to convey, ...
Pressure: 0 bar - 350 bar
... — The VSK* valves are shuttle type, cartridge version and it can be used in panels and blocks. — The valve select the higher pressure signal between “1” and “3” through ...
Pressure: 350 bar
Temperature: -54 °C - 204 °C
Flow rate: 12 l/min
... A screw-in, cartridge-style shuttle valve, for use in blocking circuits where a priority of flow/direction is given to a higher pressure circuit. Flow: See performance chart Internal leakage: 0.25 mL/min (5 drops/min) ...
Hydrabase
DN: 0.125 in - 0.5 in
Pressure: 2 bar - 10 bar
Temperature: -10 °C - 130 °C
... FARBO has a wide range of valves used for the pneumatic circuitry. Besides non-return valves, available both for power circuits that control, also quick exhaust and logical OR type valves. A technical ...
DN: 25 mm - 150 mm
Pressure: 5 bar
... provided leakage outlet of the valve without intermixing with the product being in the second pipe. For shut-off between the central and the lower valve housing, only one seal is used. The VARIVENT® Mixproof Shuttle ...
Temperature: -5 °C - 60 °C
... Shuttle Valve Quality, we only produce top-level quality products, we promise that all of our product's raw material are first class, and good quality system controls, so our goods' quality is very good.... Products ...
DN: 0.125 in - 0.75 in
Pressure: 3,000 psi
... The shuttle valve permits flow from either of two inlet ports to a common outlet. A free floating metal ball shuttles according to the relative pressure at the two inlets. The higher pressure inlet flows ...
KEPNER
Pressure: 240 bar
Temperature: -40 °C - 120 °C
... Compact size · Rapid response to load direction changes. Operation The valve will allow flow from the higer pressure of ① or ③ port to the ② port. The valve is commonly used to direct oil from the pressure ...
Wenzhou Meric Hydraulic Technology Co.,Ltd
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group