- Electricity - Electronics >
- Switch and Relay >
- Voltage circuit breaker
Voltage circuit breakers
Primary current: 630, 1,250, 2,000 A
VAC: 12 kV
... The BSR is an OEM designed retrofit circuit breaker for both the BRUSH Switchgear VSI range of Oil Circuit Breakers and the VMV vacuum Circuit Breaker, ...
Primary current: 0.1 A - 50 A
VAC: 415, 250, 240, 80, 32 V
VDC: 80, 65 V
... Vibrations: IEC 68-2-6 Mil-std 68-2-3 Umidity: IEC 68-2-6 Mil-std 68-2-3 Note Single or multipole small size circuit breaker, handle, rocker or sealed mount toogle, also available with snap-in mounting, ...
COMESTERO SISTEMI
VAC: 660, 690 V
... sensor .the circuit breaker can be used as an isolator with the mark The circuit breaker complies with the requirements of the standards GB140482″Low voltage switchgear ...
Primary current: 400 A - 2,000 A
VAC: 400, 690 V
... marine type and 1E circuit breakers, circuit breakers with low temperature of up to -40℃, as well as LCD and LED display circuit breakers. • Intelligence, ...
Primary current: 0 A - 1,600 A
VAC: 550, 800 V
... of a circuit breaker provides the feature of inverse time-delay, while the magnetic release is the instantaneous operation as shown on table 2(distribution circuit breaker) and table ...
Andeli Group Company
... ZW32 outdoor High Voltage AC Vacuum circuit Breaker is a new generation outdoor vacuum circuit breaker researched and developed recently based on the foreign advanced ...
Primary current: 400 A - 6,300 A
VAC: 400, 690 V
... RDW1-2000~6300 air circuit breaker, applied to power distribution network of AC50Hz,rated operational voltage up to 690V,Rated current from 400A to 6300A. It is mainly used to distribute powerand protect ...
PEOPLE ELE. APPLIANCE GROUP CO., LTD.
Primary current: 40 A
VAC: 240 V
VDC: 50 V
... Circuit Breakers, Thermal, Series Trip, Silver, Operating Voltage 240 VAC, Operating Voltage 50 VDC, 40A Current Rating, Potter & Brumfield W23-31 • Circuit Breaker ...
Primary current: 40 mA
VDC: 19 V - 30 V
Rating: 30 A
... Input voltage required to switch on the outputs, typ. - 19 Vdc Output data Output current (sum of all outputs) - 30 A Turn-on delay of outputs - 750 ms Overview Dimensions (WxHxD) - 52 mm x 124 mm x 130 mm Weight per unit ...
PULS GmbH
Primary current: 6,000 A
VAC: 230, 400 V
... SFB2A series circuit breakers are applicable for places with AC 50Hz or 60Hz, rated voltage of 400V and below, and rated current of 16A-80A. It is mainly used for overload and short- circuit ...
Primary current: 25 A
... 25А – automatic shutdown system voltage at the high voltage. Protection loss of neutral. It is used to protect electrical equipment, household, industrial and office equipment from accidents in the power grid. ver ...
Primary current: 5, 25, 15, 30 A
VDC: 65 V
... ICT snap in circuit breakers are designed to provide reliable, long lasting service where high voltage and current handling are required. Features & Benefits 5-, 10-, 15-, 25- and 30-Amp versions ...
the best suppliers
Subscribe to our newsletter
Receive updates on this section every two weeks.
Please refer to our Privacy Policy for details on how DirectIndustry processes your personal data.
- Brand list
- Manufacturer account
- Buyer account
- Our services
- Newsletter subscription
- About VirtualExpo Group