OverviewFast mass flow controllers that use laminar differential pressure (DP) measurement technology for automated measurement and control of gases. Designed for industrial processes and research applications with wide full-scale flow and pressure options, multiple series variants for different applications, and numerous communication and build options.
Key features- Laminar DP (differential pressure) mass flow measurement technology
- Measures mass flow, volumetric flow, temperature, and pressure
- 98–130 pre-loaded gas calibrations (varies by series)
- Ultra-fast control response time as low as 30 ms
- Measurement and control range as high as 0.01% – 100% (10,000:1 turndown) for some variants
- Operating pressure ranges from low vacuum to high pressure options depending on series
- Limited lifetime warranty
Performance highlights- Full scale flow ranges: 0.5 SCCM – 12,000 SLPM (series- and model-dependent)
- Operating pressure range (examples): 11.5 – 160 PSIA (typical MC series), up to 320 PSIA for high-pressure variants
- Accuracy examples: as good as ±0.5% of reading or ±0.1% of full scale (whichever is greater) for standard MC; corrosion-resistant variants can achieve ±0.4% of reading and ±0.2% of full scale
- Control response: as fast as 30 ms (some high-pressure variants 100 ms)
Available series and purpose- MC Series — flagship general-purpose laminar DP mass flow controllers; fast proportional control; wide flow options (0.5 SCCM – 12,000 SLPM)
- MCS Series — corrosion-resistant controllers with reduced wetted materials; up to ~130 corrosive and non-corrosive gas calibrations preloaded; accuracy examples ±0.4% reading / ±0.2% full scale
- MCQ Series — high-pressure controllers for higher-pressure processes; operating to higher PSIA ratings and appropriate accuracy tradeoffs
- BIOC Series — controllers designed for bioreactors and fermenters; ASME BPE compliant, long-term stability, compliant materials (including USP Class VI elastomers) and designed for scalability (10,000:1 operating range)
- MCD Series — bi-directional mass flow controllers with two valves to control flow in two directions
- MCT Series — devices that switch between two gas sources (two sources, one device)
- MCW / MCWD — low pressure drop laminar DP MFCs
- SFF / MCV — options for vacuum pressures and SEMI footprint
- IS‑Max — intrinsically safe MFCs for explosive atmospheres (intrinsically safe series)
Build options and selectionsCommunication Protocols: RS-232 Serial (default); RS-485 Serial; Analog (4–20 mA, 0–10 Vdc, 0–5 Vdc, or 1–5 Vdc); Modbus RTU (over RS-232 or RS-485); Modbus TCP/IP; DeviceNet; EtherCAT; EtherNet/IP; PROFIBUS; PROFINET; IO-Link
Displays: Backlit monochrome (default) or TFT color; integrated or panel-mount; none
Process Connections: 10-32, NPT, SAE, BSPP, VCRM, VCO, Compression fittings (selection varies by model)
Ingress Protection: IP40 (default); optional IP66, IP67
Hazardous Environment Ratings: Options for CSA Class 1 Div 2 and ATEX Class 1 Zone 2 builds (series/option dependent)
Humid Gases: Relative humidity compensation available
Measurement Technology: Laminar differential pressure (laminar DP) flow sensing with temperature and pressure correction
Spec sheet families / model groups- MC family spec ranges (low / mid / high full-scale groups cover 0.5–12,000 SLPM depending on range)
- MCS family spec sheets cover corrosion-resistant options and their ranges
- MCQ family spec sheets cover higher-pressure controller options
- BIOC family spec sheets cover bioreactor / fermenter-specific ranges and compliance
Additional notesMany MC-series instruments are available with options for hazardous-area builds, different display and connector options, and a wide range of communication protocols and fittings. Instruments are made-to-order with selectable calibration and accuracy options.
Technical specifications- Measurement method: Laminar differential pressure (laminar DP) with temperature and pressure correction
- Measured variables: Mass flow, volumetric flow, temperature, pressure
- Full scale flow ranges: 0.5 SCCM – 12,000 SLPM (model-dependent)
- Flow meter/controller ranges listed on product pages: examples include 0.5 SCCM, 1 SCCM, 2 SCCM, 5 SCCM, 10 SCCM, 20 SCCM, 50 SCCM, 100 SCCM, 200 SCCM, 500 SCCM, 1 SLPM, 2 SLPM, 5 SLPM, 10 SLPM, 20 SLPM, 50 SLPM, 100 SLPM, 250 SLPM, 500 SLPM, 1,000 SLPM, etc.
- Operating pressure: typical MC 11.5 – 160 PSIA; MCQ up to 320 PSIA (variant-dependent)
- Accuracy examples: down to ±0.4%–±0.6% of reading or ±0.1%–0.2% of full scale depending on series and calibration
- Control range / turndown: up to 10,000:1 for some MC/BIOC variants; others 200:1 or 1–100% depending on series
- Control response: as fast as 30 ms (typical high-speed response); some high-pressure variants ~100 ms
- Preloaded gas calibrations: typically dozens to over a hundred (e.g., 98–130 gas calibrations depending on series)
- Displays: Backlit monochrome or TFT color, integrated or panel-mount options, or no display
- Communications: Analog, RS-232, RS-485, Modbus RTU, Modbus TCP/IP, DeviceNet, EtherCAT, EtherNet/IP, PROFIBUS, PROFINET, IO-Link
- Process connections: 10-32, NPT, SAE, BSPP, VCRM, VCO, Compression (model-dependent)
- Ingress protection options: IP40 default; IP66 / IP67 optional
- Hazardous area build option: -X build for CSA Class 1 Division 2 / ATEX Zone 2; intrinsically safe IS-Max series available for more hazardous zones