Proxis T series melt blown cartridges are nominal rated with a particle removal efficiency of 90% at the designated micron rating.
Proxis A series melt blown cartridges are absolute rated with a particle removal efficiency of 99.9% at the designated micron rating.
Proxis cartridges have a 100% polypropylene construction, and feature an inner core to enhance mechanical strength. They have a graded density structure, and have no contaminant downloading even at high differential pressures.
Available in a wide range of micron sizes from 0.5 – 150.
Standard length : 4 7/8” to 40”.
Custom lengths up to 60” possible.
Standard diameter : I.D. 27.5mm, O.D. 63.5mm.
Available in large 110mm diameter, 10″ and 20″ lengths for higher flow rates and dirt holding capacity.
Can be fitted with all industry standard end caps
Most commonly double open ended, but can be fitted with all industry standard end caps.
O-rings for end caps include Nitrile, EPDM, Silicone, Viton, PTFE encapsulated Viton, PTFE encapsulated Silicone.
Maximum recommended differential pressure : 2.6 Bar (1 Bar @ 82°C, 2 Bar @ 66°C, 4.2 Bar @ 24 °C).
Maximum recommended temperatures : 59°C – double open ended versions 82°C – all single open ended versions.
Cartridges will easily rinse-up to 18 Megohm-cm.
Toxicity: Cartridges are appropriate for use in pharmaceutical applications. Components meet USP-XXIII, Class VI criteria.
Purity: Proxis melt blown cartridges are made of polypropylene resin meeting FDA regulation 21 CFR 177.1520. No binders, lubricants or anti-static agents are used in the manufacturing process.