Characteristics

Drying method
hot air
Operating temperature

Max.: 250 °C
(482 °F)

Min.: 10 °C
(50 °F)

Description

Product description
The Solid.Line FD-S 115 from BINDER is designed for controlled drying and heating applications in research and quality assurance. It combines APT.line™ preheating chamber technology with forced convection to ensure reproducible thermal processes.

Benefits
  • Easy handling
  • Accurate temperature control
  • Simple and ergonomic door opening


Important characteristics
  • Temperature range: +10 °C above ambient temperature to +250 °C
  • APT.line™ preheating chamber technology
  • Forced convection
  • Adjustable exhaust air flap
  • Controller with timer function
  • 1 chrome-plated rack, incl. shelf supports
  • Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm


Data
Article Number | 9090-0024 | 9090-0025
Designation | FDS115-230V | FDS115UL-120V
Option model | Standard | Standard

Performance Data - Temperature
Article Number | 9090-0024 | 9090-0025
Temperature range | +10 °C above ambient temperature to 250 °C | +10 °C above ambient temperature to 250 °C
Temperature uniformity at 150°C | 2.0 ± K | 2.0 ± K
Temperature fluctuation at 150°C | 0.4 ± K | 0.4 ± K
Heating up time to 150°C | 20 min | 20 min
Recovery time after door was opened for 30 s at 150°C | 8 min | 8 min

Air change data
Article Number | 9090-0024 | 9090-0025
Air change rate at 100°C | 2 x/h | 2 x/h

Electrical data
Article Number | 9090-0024 | 9090-0025
Rated Voltage | 230 V | 120 V
Power frequency | 50/60 Hz | 60 Hz
Nominal power | 1,3 kW | 1,4 kW
Unit fuse | 6,3 A | 6,3 A
Phase (Nominal voltage) | 1~ | 1~

Dimensions and weights
Article Number | 9090-0024 | 9090-0025
Interior volume | 106 L | 106 L
Net weight of the unit (empty) | 48 kg | 48 kg
Load per rack | 20 kg | 20 kg
Permitted load | 75 kg | 75 kg
Wall clearance back | 160 mm | 160 mm
Wall clearance sidewise | 100 mm | 100 mm

Housing dimensions (net, not incl. fittings and connections)
Article Number | 9090-0024 | 9090-0025
Width net | 764 mm | 764 mm
Height net | 735 mm | 735 mm
Depth net | 616 mm | 616 mm

Internal Dimensions
Article Number | 9090-0024 | 9090-0025
Interior width | 550 mm | 550 mm
Interior height | 550 mm | 550 mm
Interior depth | 350 mm | 350 mm
Unit doors | 1 | 1

Environment-specific data
Article Number | 9090-0024 | 9090-0025
Sound-pressure level | 48 dB(A) | 48 dB(A)
Energy consumption at 150°C | 340 Wh/h | 340 Wh/h

Fixtures
Article Number | 9090-0024 | 9090-0025
Number of shelves (std./max.) | 1/5 | 1/5

Options / Accessories / Services (selection)
  • Grid shelf (chrome plated), incl. shelf supports (8012-1808)
  • pH-neutral detergent (1 kg) (8012-2250)
  • Rubber pads / anti-slip feet (8012-2030)
  • Maintenance contracts: BRONZE / SILVER / GOLD (DL20-0720 / DL20-0810 / DL20-0910)
  • Calibration certificates, temperature and temperature mapping options (DL30-0120, DL30-0102, DL30-0109, DL30-0127)
  • Measurement of air exchange rate including certificate (DL33-0000)
  • Warranty extension 1 year (DL50-0010)


Characteristics / technical specifications
  • Model: FD-S 115
  • Application: Drying and heating with forced convection
  • Temperature range: +10 °C above ambient to +250 °C
  • Preheating chamber technology: APT.line™
  • Convection: Forced convection
  • Exhaust: Adjustable exhaust air flap
  • Controller: with timer function
  • Safety device: Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
  • Interior volume: 106 L
  • Internal dimensions (W×H×D): 550 × 550 × 350 mm
  • Number of doors: 1
  • Standard shelves: 1 (max. 5)
  • Load per rack: 20 kg; Permitted load: 75 kg
  • Net weight (empty): 48 kg
  • Rated voltage options: 230 V (nom.), 120 V (optional)
  • Nominal power: 1.3 kW (230 V) / 1.4 kW (120 V)
  • Unit fuse: 6.3 A
  • Phase: single-phase (1~)
  • Air change rate at 100°C: 2 x/h
  • Temperature uniformity at 150°C: 2.0 ± K; fluctuation: 0.4 ± K
  • Heating-up time to 150°C: 20 min; Recovery time after 30 s door opening at 150°C: 8 min
  • Sound-pressure level: 48 dB(A)
  • Energy consumption at 150°C: 340 Wh/h
  • Wall clearances: back 160 mm; sidewise 100 mm

Catalogs

No catalogs are available for this product.

See all of BINDER‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

Oslo Battery Days
Oslo Battery Days

24-25 Aug 2026 Oslo (Norway)

  • More information
    LAB-SUPPLY Dresden
    LAB-SUPPLY Dresden

    8-08 Sep 2026 Internationales Congress Center (Germany)

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.