Product descriptionBINDER VDL series safety vacuum drying chamber VDL 115 is designed for secure drying of flammable organic solvents. The unit is explosion-protected and classified according to ATEX directive 2014/34/EU: EX II 2/3/- G IIB T3 Gb/Gc/- X.
Benefits- Fast and gentle drying process
- Efficient heat transfer via large thermal conducting plates
- Safe operation through ATEX-compliant safety concept
- Optional modular complete system with vacuum pump and pump chamber
Key features- Temperature range: ambient +9 °C to +110 °C
- ATEX conformity: EX II 2/3/- G IIB T3 Gb/Gc/- X
- Intuitive touchscreen controller with graphical pressure and temperature display
- Program-controlled drying monitoring with automatic ventilation at end of process
- Internal data logger; measured values exportable in open format via USB
- Pressure control device enabling heating from < 100 mbar
- Two aluminum expansion racks, custom-positionable (std./max. 2/6)
- Universal ventilation connection for ambient air or inert gas
- Universal access port DN 16 for external sensors and leads
- Shatterproof, spring-mounted safety glass panel and large viewing window
- Computer interface: Ethernet
Technical data — GeneralArticle number: 9630-0011 / 9630-0015
Designation: VDL115-230V / VDL115-120V
Option model: Standard
Performance data — TemperatureTemperature range: +9 °C above ambient temperature to 110 °C
Temperature uniformity at 100 °C: 2.9 ± K
Temperature fluctuation at 100 °C: 0.1 ± K
Heating-up time to 100 °C: 170 min
Vacuum dataLeak rate: 0.01 bar/h
Pressure fluctuation over time at 50 mbar: 1 ± mbar
Pressure fluctuation over time at 400 mbar: 70 ± mbar
Electrical dataArticle numbers: 9630-0011 (200...230 V) / 9630-0015 (100...120 V)
Rated voltage: 200...230 V (9630-0011) / 100...120 V (9630-0015)
Power frequency: 50/60 Hz
Nominal power: 1.6 kW
Unit fuse: 10.0 A (230 V) / 20.0 A (120 V)
Phase (nominal voltage): 1~
ConnectionsVacuum connection with small flange: DN 16 mm
Measuring access port with small flange: DN 16 mm
Dimensions and weightsInterior volume: 119 L
Net weight (empty): 158 kg
Load per rack: 20 kg
Permitted total load: 70 kg
Wall clearance back: 100 mm
Wall clearance sidewise: 70 mm
Housing dimensions (not incl. fittings and connections)Width net: 743 mm
Height net: 942 mm
Depth net: 581 mm
Internal dimensionsInterior width: 506 mm
Interior height: 506 mm
Interior depth: 460 mm
Unit doors: 1
Environment-specific dataSound-pressure level: 40 dB(A)
Energy consumption at 100 °C: 230 Wh/h
FixturesNumber of shelves (std./max.): 2 / 6
Options, accessories & services (selection)- Expansion racks — stainless steel or aluminum
- Door gasket (FKM, silicone-free)
- Calibration certificates (temperature and pressure variants)
- Additional ventilation connection for ambient air or inert gas
- Universal access port DN 40 (small flange)
- Analog output 4-20 mA for temperature and pressure
- Specimen temperature measurement with flexible Pt100 and digital display
- Pump chamber for vacuum pump installation and ATEX vacuum pump VP5 EX
- Service options: pump maintenance, one-off maintenance, maintenance contracts, IQ/OQ/PQ, commissioning, warranty extension
- Software options: APT-COM™ (BASIC / PROFESSIONAL / GLP)
Specifications / technical data- Product / Model: VDL 115
- Brand: BINDER
- Article numbers: 9630-0011 (230 V) and 9630-0015 (120 V)
- Temperature range: ambient +9 °C to +110 °C
- Temperature uniformity (100 °C): 2.9 ± K
- Temperature fluctuation (100 °C): 0.1 ± K
- Heating-up time to 100 °C: 170 min
- Interior volume: 119 L
- Interior dimensions (W×H×D): 506 × 506 × 460 mm
- Net weight (empty): 158 kg
- Load per rack: 20 kg — permitted total load: 70 kg
- Number of shelves (std./max.): 2 / 6
- Vacuum connection / measuring access port: DN 16 mm
- Leak rate: 0.01 bar/h
- Pressure stability: 1 ± mbar at 50 mbar; 70 ± mbar at 400 mbar
- Rated voltage / power: 200...230 V or 100...120 V; 1.6 kW; 50/60 Hz; single phase
- Safety / Certification: ATEX EX II 2/3/- G IIB T3 Gb/Gc/- X
- Interfaces & monitoring: Touchscreen with graphical pressure & temperature display; internal data logger with USB export; Ethernet
- Special features: Program-controlled drying monitoring with automatic ventilation at end of process; pressure control device for heating from <100 mbar; shatterproof spring-mounted safety glass