Infrared temperature sensor PyroCV
with housingin metal housingthreaded

Infrared temperature sensor - PyroCV - Calex Electronics Limited - with housing / in metal housing / threaded
Infrared temperature sensor - PyroCV - Calex Electronics Limited - with housing / in metal housing / threaded
Infrared temperature sensor - PyroCV - Calex Electronics Limited - with housing / in metal housing / threaded - image - 2
Infrared temperature sensor - PyroCV - Calex Electronics Limited - with housing / in metal housing / threaded - image - 3
Infrared temperature sensor - PyroCV - Calex Electronics Limited - with housing / in metal housing / threaded - image - 4
Add to favorites
Compare this product

Characteristics

Technology
infrared
Mounting
threaded, screw-in, with housing, in metal housing
Output
CAN, 0-5 V
Electrical connection
M12 connector, built-in transmitter
Process connection
M18 x 1,5
Protection level
IP65, IP67
Other characteristics
stainless steel, compact, high-precision, non-contact, fast-response, low-temperature
Temperature

Max.: 500 °C
(932 °F)

Min.: -20 °C
(-4 °F)

Spectral range

Max.: 14 µm

Min.: 8 µm

Response time

125 ms

Description

Short description
The PyroCV is a compact infrared non-contact temperature sensor designed for construction machinery, offering CAN communications or a linear 0–5 V output. No complex setup is required: connect a temperature indicator and power supply to begin measurements immediately.

Sensor Features
  • Tested to EMC standards for construction machinery (ISO 13766-1)
  • Non-contact measurement of asphalt and other non-reflective construction materials
  • Temperature ranges from -20°C to 500°C (model dependent)
  • Durable stainless steel 316 housing, sealed to IP67 / IP65 when mated
  • Quick installation via M12 connector and M18 x 1 mm thread
  • Outputs: CAN (raw) or linear 0–5 V DC
  • Fast response and high stability


General Specifications
Output: Raw CAN and 0 to 5 V DC linear with measured temperature
Temperature range: CAN models: -20°C to 500°C; Voltage models: LT: -20°C to +100°C, MT: 0°C to 250°C, HT: 0°C to 500°C, ST: customer selectable within -20°C to 500°C (minimum span 100°C)
Accuracy: ±1% of reading or ±1°C, whichever is greater
Repeatability: ±0.5% of reading or ±0.5°C, whichever is greater
Emissivity: CAN configurable 0.2–1.0; Voltage fixed 0.95
Startup time: 250 ms; Response time: 125 ms (90%)
Spectral range: 8–14 μm
Supply voltage (sensor): 10–28.8 V DC; Max. current draw: 20 mA
Minimum load resistance (voltage only): 50 kΩ
Wiring protection: reverse polarity and shorts to other pins

CAN Protocol Specifications
Baud rate: 250 kbps
Data format: 8 bytes — Bytes 1–4: object temperature (float); Bytes 5–8: ambient temperature (float)
Transmit interval: 200 ms
CAN ID: configurable 0–255 as a 4-byte unsigned integer
Emissivity: adjustable 0.2–1.0 as a 4-byte float

Field of View / Optics
Detects infrared wavelengths (8–14 μm) with spot sizes defined to contain 90% of detected energy. For best accuracy target size should be at least twice the measured spot. Longer distances are possible with larger measured spot sizes.

Mechanical Specifications
Construction: Stainless steel 316
Dimensions: sensor body length 86.5 mm
Thread mounting: M18 x 1 mm pitch, length 60 mm
Weight: 90 g

Environmental Specifications
Ingress protection: IP67 / IP65 (when mated)
Operating ambient temperature & humidity: -40°C to +85°C, no condensation
Storage temperature: -40°C to +85°C

Electromagnetic Compatibility (EMC)
Tested to ISO 13766-1; load-dump tested according to ISO 16750-2 (clamped). System-level protection against unclamped load dump must be ensured in the host electrical system.

Applications
Designed for non-contact temperature measurement on non-reflective, non-metal surfaces such as asphalt, concrete, bulk materials, painted surfaces, thick plastics, rubber and organic materials. Typical uses: asphalt paving, road rollers, concrete processing and curing.

Technical specifications
  • Model: PyroCV
  • Outputs: Raw CAN; 0–5 V DC linear
  • Temperature ranges: CAN: -20°C to 500°C; Voltage: LT -20°C to +100°C, MT 0°C to 250°C, HT 0°C to 500°C, ST customer selectable (min span 100°C)
  • Accuracy: ±1% of reading or ±1°C
  • Repeatability: ±0.5% of reading or ±0.5°C
  • Emissivity: CAN 0.2–1.0 configurable; Voltage fixed 0.95
  • Startup time: 250 ms; Response time: 125 ms (90%)
  • Spectral range: 8–14 μm
  • Supply voltage: 10–28.8 V DC; Max current draw: 20 mA
  • Min load (voltage): 50 kΩ
  • Wiring protection: reverse polarity; shorts to other pins
  • CAN: 250 kbps, 8-byte data (object + ambient floats), transmit interval 200 ms, CAN ID 0–255
  • Construction: Stainless steel 316; Sealing: IP67 / IP65 (when mated)
  • Dimensions: body length 86.5 mm; Thread: M18 x 1 mm, length 60 mm; Weight: 90 g
  • Operating temp/humidity: -40°C to +85°C, no condensation; Storage: -40°C to +85°C
  • EMC: tested to ISO 13766-1; load-dump tested to ISO 16750-2 (clamped)