Number of axes
1-axis
Application domain
for medical applications

Description

Product
GVM/GVMW-2264

Available documents
  • Mirror (PDF)
  • Driver (PDF)
  • 3DCAD STEP (ZIP)


General note
Scanner drawing with GM2 mirror assembly.

Scanner Specifications
  • Maximum Scan Angle — deg (mechanical): GVM-2264 ±20; GVMW-2264 ±40
  • Rotor Inertia: 0.97 g·cm^2
  • Coil Resistance: 1.15 ±10% Ω
  • Coil Inductance: 0.155 ±10% mH
  • Torque Constant: 13.4 ±10% mN·m/A
  • Back EMF Voltage: 0.232 ±10% mV/deg/sec
  • Peak Current: 20 A (Max.)
  • Maximum Coil Temperature: 110 °C
  • Weight: 210 g


Dynamic Specifications
  • Repeatability: 8 µrad
  • Non-Linearity (±10°): 0.1% (Max.)
  • Non-Linearity (±20°): GVMW-2264 0.3% (Typ.)
  • Non-Linearity (±30°): GVMW-2264 0.8% (Typ.)
  • Non-Linearity (±40°): GVMW-2264 3.0% (Typ.)
  • Offset Drift: 10 µrad/°C (Max.)
  • Gain Drift: 30 ppm/°C (Typ.)
  • Step Response Time: see caution (※) — depends on mirror size and scanner combination
  • Output Signal Common Mode: GVM-2264 350 µA (Typ.), GVMW-2264 468 µA (Typ.)
  • Output Signal Differential Mode: GVM-2264 11 µA/deg (Typ.), GVMW-2264 10 µA/deg (Typ.)
  • Input Signal: 30 mA (Typ.)


Notes
  • All specifications are assured when using Citizen Chiba servo driver and mirror.
  • All angles are mechanical degrees.
  • Data including step response time can be provided for preferred combinations of mirror size and scanner.


Caractéristiques / spécifications techniques
  • Model: GVM/GVMW-2264
  • Maximum Scan Angle: GVM-2264 ±20° (mechanical); GVMW-2264 ±40° (mechanical)
  • Rotor Inertia: 0.97 g·cm^2
  • Coil Resistance: 1.15 ±10% Ω
  • Coil Inductance: 0.155 ±10% mH
  • Torque Constant: 13.4 ±10% mN·m/A
  • Back EMF Voltage: 0.232 ±10% mV/deg/sec
  • Peak Current: 20 A (Max.)
  • Maximum Coil Temperature: 110 °C
  • Weight: 210 g
  • Repeatability: 8 µrad
  • Non-Linearity (±10°): 0.1% (Max.)
  • Offset Drift: 10 µrad/°C (Max.)
  • Gain Drift: 30 ppm/°C (Typ.)
  • Output Signal Common Mode: GVM-2264 350 µA (Typ.), GVMW-2264 468 µA (Typ.)
  • Output Signal Differential Mode: GVM-2264 11 µA/deg (Typ.), GVMW-2264 10 µA/deg (Typ.)
  • Input Signal: 30 mA (Typ.)