Access-control door with hatchcover for any type of standard ladder with cage, fixed at the top of the ladder, preventing unauthorized and/or non-entitled people from descending
Locking by tailed lock
Unlocking with panic bar implemented on the inner side of the access-control door
GROUPS OF USERS
Industry
Engineering offices
Architects, control offices
Water towers, waste-water treatment plants ...
PRODUCT DESIGNED FOR
One way access (climbing and descending with the same ladder)
Multiple access (ladders which are connected together, emergency exit ...)
REFERENCES
CEC610A : hinges on the right hand side, door + upper hatchcover
CEC620A : hinges on the left hand side, door + hatchcover
CEC710A : hinges on the right hand side, door without hatchcover
CEC720A : hinges on the left handside, door without hatchcover
ASSEMBLY
The access-control door is supplied with two hinges already fixed on a steel post 50 x 50 x 4 mm
A second steel post is supplied with the lock striker already fixed
Both posts have a floor fixing plate (fixing bolts and fastening pins are not included.
ADDITIONAL INFORMATION
Equipment in compliance with following standards :
- NF E 85-012 : September 2021
- EN ISO 14122-4 : March 2017
Warranty : 12 months
TECHNICAL FEATURES
Double wall door (steel sheet 1.5 mm dick)
Panic bar to be pushed from the inner side of the cage when climbing up
Galvanized spring-loaded hinges to set for self-closing
Tailed lock with European barrel and 3 keys