video corpo

Photon counting spectrofluorometer FE30
time-integrationfor waterfluorescence lifetime measurement

Photon counting spectrofluorometer - FE30 - Edinburgh Analytical - time-integration / for water / fluorescence lifetime measurement
Photon counting spectrofluorometer - FE30 - Edinburgh Analytical - time-integration / for water / fluorescence lifetime measurement
Photon counting spectrofluorometer - FE30 - Edinburgh Analytical - time-integration / for water / fluorescence lifetime measurement - image - 2
Photon counting spectrofluorometer - FE30 - Edinburgh Analytical - time-integration / for water / fluorescence lifetime measurement - image - 3
Photon counting spectrofluorometer - FE30 - Edinburgh Analytical - time-integration / for water / fluorescence lifetime measurement - image - 4
Photon counting spectrofluorometer - FE30 - Edinburgh Analytical - time-integration / for water / fluorescence lifetime measurement - image - 5
Photon counting spectrofluorometer - FE30 - Edinburgh Analytical - time-integration / for water / fluorescence lifetime measurement - image - 6
Add to favorites
Compare this product

Characteristics

Options
for photon counting, time-integration, for water, fluorescence lifetime measurement, NIR
Length

66 cm
(26 in)

Width

60 cm
(23.6 in)

Height

25 cm
(9.8 in)

Description

The FE30 Analytical Fluorescence Spectrometer is a high sensitivity, user-friendly instrument designed for both routine laboratory work and advanced research applications. It is essential for various qualitative and quantitative analyses, offering optimized optical and electronic systems to achieve industry-leading sensitivity. The FE30 delivers a water Raman Signal-to-Noise level up to 15,000:1 (RMS-BG), enabling the measurement of samples with very low emission or concentration. Its extended wavelength range up to 900 nm allows for the detection of long-wavelength emissions, such as those from iodocyanine green. The instrument supports rapid 3D scanning, providing comprehensive spectral information about unknown samples and enabling a full 3D scan in just two minutes, significantly reducing analysis time compared to traditional methods.

Key Features
  • Excellent signal-to-noise ratio: 15,000:1 (RMS-BG)
  • Fast spectrum scan: speed up to 60,000 nm/min
  • Extended wavelength range up to 900 nm
  • Spectracle: easy-to-use and powerful software
  • Validation program: automatically checks instrument health status


Software
  • Spectracle software is designed for ease of use and powerful functionality, utilizing a Workspace concept for efficient creation, calculation, and combination of scans for analysis and reporting.
  • Basic functions include Excitation and Emission scans, 3D Scans, Time Scan, Synchronous Scan, Fluorescence, Quantitation, and Validation.
  • Users can store routine applications and generate reports with a single click.


Measurement Examples
  • Life science: Polarization of Rhodamine 6G
  • Food science: Determination of Vitamin B2
  • Environmental: 3D spectrum of CDOM in marine water
  • Pharmaceutical: Quantitation of Quinine
  • Material science: Study of quenching fluorescence
  • Industrial: Measurement of brightener


Options and Upgrades
  • Thermostated Cell Holder with Circulating Bath: Controls sample cell temperature up to 80°C for biological samples
  • Polariser: For protein, enzymology, and cellular studies
  • Trace Solid Sample Holder - Adjustable Angle: For powder and thin film samples, adjustable 0–90° horizontally
  • Solid Sample Holder - Adjustable Angle: For powder and thin film samples, adjustable 0–90° horizontally
  • Solid Sample Holder - High Temperature: For thermo-furo experiments, temperature range 25–300°C
  • Water Bath Magnetic Stirring Cell Holder: Adjustable stirring speed, temperature control range ambient–80°C, stirrer size 3x6 mm or 2x7 mm


Characteristics / Technical Specifications
  • Excitation source: High Intensity 150 W Continuous Xenon Lamp
  • Wavelength Measurement Range: Excitation (EX) 200–900 nm, Emission (EM) 200–900 nm
  • Spectral Bandwidth: Excitation and Emission: 1, 2.5, 5, 10, 20 nm (5 steps)
  • Wavelength accuracy: Excitation ±2 nm, Emission ±2 nm
  • Wavelength repeatability: Excitation ±1 nm, Emission ±1 nm
  • Sensitivity: Signal-to-Noise level using Raman peak of water, excitation 350 nm is 750:1 (RMS noise at Raman peak), 15,000:1 (RMS noise at background)
  • Optical platform: One-piece cast aluminium base for stability and collimation
  • Wavelength scan speed: Max 60,000 nm/min; selectable from 30, 60, 240, 1,200, 2,400, 12,000, 60,000 nm/min
  • Scan Interval: 0.1–10.0 nm
  • Auto gain: 0–1,000 V adjustable
  • Fluorescence Intensity Drift: <1.5% (Ex: 350 nm, Em: 450 nm within 10 min)
  • Fluorescence Value Range: 0 to 50,000
  • Detector: Photomultiplier tube R928
  • Software: Spectracle PC-controlled software
  • Sample Chamber Dimension: 247 (W) × 215 (D) × 172 (H) mm
  • Instrument Dimension (L×D×H): 660 (W) × 600 (D) × 250 (H) mm
  • Weight: 50 kg