Cooling tower air inlet louvre INLETpack

Cooling tower air inlet louvre - INLETpack - ENDEVION SRL
Cooling tower air inlet louvre - INLETpack - ENDEVION SRL
Cooling tower air inlet louvre - INLETpack - ENDEVION SRL - image - 2
Cooling tower air inlet louvre - INLETpack - ENDEVION SRL - image - 3
Cooling tower air inlet louvre - INLETpack - ENDEVION SRL - image - 4
Cooling tower air inlet louvre - INLETpack - ENDEVION SRL - image - 5
Cooling tower air inlet louvre - INLETpack - ENDEVION SRL - image - 6
Cooling tower air inlet louvre - INLETpack - ENDEVION SRL - image - 7
Cooling tower air inlet louvre - INLETpack - ENDEVION SRL - image - 8
Cooling tower air inlet louvre - INLETpack - ENDEVION SRL - image - 9
Cooling tower air inlet louvre - INLETpack - ENDEVION SRL - image - 10
Cooling tower air inlet louvre - INLETpack - ENDEVION SRL - image - 11
Add to favorites
Compare this product

Characteristics

Applications
for cooling towers

Description

Overview
ENDEVION supplies spare parts and components with advanced efficiency classes for all sizes and construction types to meet industrial requirements for evaporative cooling towers.

FAN GROUPS
  • High-efficiency motors. ENDEVION can supply corrosion and environment-specific protection coatings adapted to coastal, industrial or desert conditions.
  • FANS: ENDEVION analyses fan stability and vibrations and can repair or restore surface coatings to avoid replacement. New fan designs enable higher capacity or reduced power absorption at the same airflow to lower electrical consumption.
  • MECHANICAL GROUP: Customized combinations of drive shafts and speed reducers to meet customers' reliability and efficiency targets.


DRIFT ELIMINATORS — DRIFTpack
ENDEVION modular PP or PVC drift eliminators provide high separation efficiency and suit small to medium evaporative towers. Lamella-profile drift eliminators are preferred for large or natural-draft towers. All products are certified.

ADVANTAGES OF ENDEVION DRIFT ELIMINATORS
  • High separation efficiency
  • Reduced pressure drop
  • Customizable geometry; available in PP and PVC
  • Different stability grades


AIR INLET LOUVRES — INLETpack
INLETpack improve airflow inside the cooling tower, reduce sunlight penetration to limit algae growth and are manufactured in PP or PVC for long service life. Suitable for both cross-flow and counter-flow towers, they offer high stability, dimensional customization and reduced pressure drop.

ADVANTAGES of INLETpack ENDEVION
  • Reduce wind sensitivity of evaporative towers
  • Lower noise emissions
  • Minimize loss of water-treatment chemicals due to peripheral splash-out
  • Act as rectifiers of incoming airflow
  • Prevent ice formation in cold climates
  • Block leaves and debris from entering the cooling circuit
  • MATERIALS: impact-resistant, environmentally friendly PP; non-plasticized PVC (uPVC). Both resist fungi, molds, most chemicals and UV.
  • Available on request in flame-retardant version
  • Tailor-made solutions available; dimensional tolerance +/- 20 mm or 2% (whichever is greater)


Other spare parts for evaporative towers
  • FAN-STACK: repair, full replacement or performance upgrade; ENDEVION provides durable turnkey solutions integrated with existing systems.
  • STRUCTURE AND CLADDING: options in AISI 304/316, aluminium, galvanised or painted steel, or FRP depending on application and customer standards.
  • WATER DISTRIBUTION: revamp worn channels and pipes or deliver fully renewed systems to preserve tower efficiency.
  • NOZZLES FOR COOLING TOWERS: wide range for all flow rates and distribution configurations; special hard-to-find nozzles available on request.
  • SUPPORT STRUCTURE: sizing of support frames for packings for any load or tower size using fiberglass, steel or wood.


Characteristics / Technical specifications
  • Materials: PP (impact-resistant, eco-friendly), non-plasticized PVC (uPVC), AISI 304/316 stainless steel, aluminium, galvanised/painted steel, FRP, fiberglass, steel, wood.
  • DRIFTpack: modular PP or PVC drift eliminators, certified for separation efficiency; lamella profile for large or natural-draft towers.
  • INLETpack: PP or PVC inlet louvres; customizable dimensions, anti-algae function, reduced pressure drop; flame-retardant version on request.
  • Fans and motors: high-efficiency options with protective coatings for marine, industrial or desert environments.
  • Mechanical solutions: customized drive shaft and reducer combinations to optimize reliability and efficiency.
  • Dimensional tolerances for tailor-made solutions: +/- 20 mm or 2% (whichever is greater).
  • Flame-retardant versions available on request.
  • Associated services: inspection with reporting, design, performance evaluation, revamping, vibration analysis, blade balancing, noise analysis.