Product overviewHETS-PWE-S series provides a precise, reliable and convenient test platform for PEM electrolyzers. The system consists of a gas-liquid separation unit, gas concentration monitoring unit, gas cooling and drying module, water/thermal management module, pressure interlock control module, measurement & control unit and safety module. By online data monitoring and processing on the test platform, it analyses the tested electrolyzer's performance, lifetime, reliability and safety. Suitable for R&D, qualification and end-of-line testing of PEM electrolyzers.
Key featuresHigh dynamic response: rapid adjustment capability for power, temperature/pressure/flow
Wide-range high accuracy: 5%–150% power range, 100 kPag–4 MPag gas outlet pressure, temperature ±1°C, pressure ±20 kPa, gas flow accuracy 0.8% RD + 0.2% FS
Unattended operation: script compilation, step import, one-button start/stop
HAZOP and LOPA analysis: TUV or equivalent professional inspection reports
Pure water control: in-situ online conductivity monitoring and control ≤0.5 uS/cm
Fast sampling: hydrogen-in-oxygen sampling stable and readout time ≤2 min
Optional functions and peripherals- Oxygen/gas flow and hydrogen-in-oxygen detection modules
- Custom hydrogen production power supply services
- Containerized complete solutions
- AC impedance testing
- Gas purification units
Product specification tablePage includes product specification table image (as displayed on the page).
Characteristics / Technical specifications- System composition: gas-liquid separation unit, gas concentration monitoring unit, gas cooling and drying module, water/thermal management module, pressure interlock control module, measurement & control unit, safety module.
- Target: R&D, qualification and end-of-line testing of PEM electrolyzers.
- Power / operating range: 5%–150% power range.
- Gas outlet pressure range: 100 kPag – 4 MPag.
- Temperature control accuracy: ±1°C.
- Pressure control accuracy: ±20 kPa.
- Gas flow accuracy: 0.8% RD + 0.2% FS.
- Online pure water monitoring: in-situ conductivity control ≤0.5 uS/cm.
- Fast sampling performance: hydrogen-in-oxygen sampling stable and readout time ≤2 min.
- Automation: supports script compilation, step import, unattended operation, one-button start/stop.
- Safety and compliance: supports HAZOP and LOPA analysis and provides TUV test reports where applicable.