High-temperature filter with automatic regeneration using compressed air, nitrogen, or other media, and sintered metal cartridges with a long service life of over 30,000 operating hours.
Particularly suitable for use in high-temperature operations with flue gas temperatures above 250 °C. Can be used for dust removal from flue gases in biomass-fired boilers or for syngas purification (up to 500 °C).
They are used for “retrofitting”—the conversion of older fabric filters and electrostatic precipitators.
The horizontal arrangement of the filter cartridges allows for a space-efficient layout.
The modular design facilitates transport.
TECHNICAL PARAMETERS
Capacity: 2,000–1,000,000 m³/h.
Filter area: 10–16,000 m²
Residual dust concentration at the outlet: <5 mg/Nm³
Standard operating temperature: +80°C/+500°C
Pressurized nitrogen, propane-butane, and others for syngas filtration
Compressed air: 6 bar, -40°C, consumption from 0.1–100 Nm³/h
Pressure drop: 1,000–2,000 Pa, depending on operation
DESIGN
Robust welded sheet metal housing, designed for operation under vacuum and overpressure
Filter medium: metallic cartridge, length 600–3000 mm, diameter 60–160 mm
Regeneration of the filter surface is ensured by automatic and regular backwashing via the JET-PULS system; pressure medium connection: G ½” internal thread
Pneumatic and safety valves, pressure regulator with pressure gauge
ADVANTAGES
Durable construction, modular design
Integrated automatic filter cartridge backflushing system
Excellent access to individual components and filter units
Easy replacement of filter cartridges
High dust separation efficiency