Characteristics

Technology
dynamic image analysis, digital image processing, optical
Applications
for research, for quality control, laboratory, for the pharmaceutical industry, for the food industry, process
Other characteristics
benchtop, automatic, multi-parameter, particle shape, particle size distribution, dry-type, in-line, high-performance

Description

Introduction
Winner300D is a dynamic dry particle image analyzer designed for rapid, representative particle-size and morphology analysis according to ISO/DIS-13322-2. The instrument captures real-time images of flowing samples and processes large particle datasets to deliver reproducible results with higher throughput than static imaging methods.

Main Specifications
  • Model: Winner300D
  • Standard: ISO/DIS-13322-2
  • Dimensions: 684 mm × 360 mm × 500 mm
  • Net weight: 24 kg
  • Power supply: 220 V / 50 Hz, 100 W


Measurement capabilities
Winner300D measures particle size distribution and morphology across a wide range with high accuracy and repeatability.

  • Measurement range: 10–10000 μm (customizable)
  • Accuracy (D50 deviation): ≤ 1.0%
  • Repeatability (D50 deviation): ≤ 1.0%
  • Throughput: >100000 particles/min
  • Feeding: Electromagnetic pulse vibration with 150-level speed adjustment
  • Dispersion: Electromagnetic vibration combined with ultrasonic dispersion


Optics & imaging
High-clarity optical path and high-speed imaging deliver detailed particle photos suitable for morphology analysis and automated processing.

  • Lens group: High-definition telecentric lens (optional specifications)
  • Lighting: Highlight parallel light source
  • Camera: 5-megapixel high-speed industrial camera


Software functions
Comprehensive analysis and reporting tools tailored for laboratory and production monitoring.

  • Particle-size outputs: distribution, D10, D50, D90 (configurable), maximum particle size
  • Morphology: aspect ratio, roundness, circularity and their distributions; particle images
  • Counting: particle number calculation
  • Customizable reports: headers (logo, tester info), task management, standard index gradations
  • Interface languages: Chinese and English (additional languages on request)
  • Export: Excel, PDF, and common formats


Advantages
  • Particle morphology analysis: sphericity, circularity, roundness and aspect ratio computed with a proprietary roundness module compliant with API_RP58 and industry/geological norms.
  • Large-sample dynamic measurement: captures extensive particle datasets for representative and reproducible results versus static imaging.
  • Improved image clarity: wide field design, central light path and constrained plane sampling window enhance particle image quality.
  • Offline and optional online testing: rapid offline analysis; online monitoring available via optional on-line sampling device.


Applications
Suitable for rapid analysis of dry, free-flowing powders and granules: salt, sugar, plastics, catalysts, abrasives, carbon products, sand, coal, coffee, refractories, food, polystyrene, glass, ceramics, fertilizers, pharmaceuticals, metal powder, cement, ore, standards, and similar materials.

Patents
  • Optical bench design: patent No. ZL 2014 2 0378380.8
  • 3D optical bench alignment system: patent No. ZL 2013 2 0835882.4
  • MIE scattering principle application: patent No. ZL 2013 2 0812021.4
  • Sealed sample cuvette for dry particle size analyzer: patent No. ZL.2011 2 0267646.8
  • Dual laser beam orthogonal application: patent No. ZL 2007 2 0025702.0
  • Powder dispersion pump design: patent No. ZL 2007 2 0018648.7
  • Wet circulation installation: patent No. ZL2010 2 0593526.2


Technical specifications
  • Model: Winner300D
  • Measurement range: 10–10000 μm (customizable)
  • Standard: ISO/DIS-13322-2
  • Accuracy (D50 deviation): ≤ 1.0%
  • Repeatability (D50 deviation): ≤ 1.0%
  • Throughput: >100000 particles/min
  • Dispersion: Electromagnetic vibration + ultrasonic dispersion
  • Feeding: Electromagnetic pulse vibration, 150-level speed adjustment
  • Optics: Telecentric lens (optional), highlight parallel light source
  • Camera: 5-megapixel high-speed industrial camera
  • Dimensions: 684 mm × 360 mm × 500 mm
  • Net weight: 24 kg
  • Power: 220 V / 50 Hz, 100 W
  • Software outputs: particle size distribution, roundness distribution, aspect ratio distribution; export to Excel/PDF
  • Interface languages: Chinese and English (other languages optional)