This measuring probe has been designed for accurate and risk-free humidity monitoring in potentially explosive areas. It is mainly used in challenging industrial applications and under harsh conditions.
general technical data
Measuring range - RH = 0 to 100 % RH, T = -70 to +180 °C (depending on type), Other available measurement parameters: Dew point temperature, wet-bulb temperature, absolute humidity, mixing ratio, water concentration, water mass fraction, water vapor pressure, and enthalpy
Application - Pharmaceutical industry, petrochemical industry, food technology
Version - Industrial version in wall design type (ATEX) with intelligent interchangeable probes
Outputs - 4 to 20 mA, (2 channels as optional extra)
Measurement medium - Air, compressed air, vacuum
Special features - Housing with LCD display and operator panel; 6 probes with various process connections and cable 2 m, 5 m, or 10 m in length
Voltage supply - DC 24 V (via [Ex i] supply isolator or Zener barrier)