Optical pyrometer CellaCast PA 81
LEDRS485USB

Optical pyrometer - CellaCast PA 81 - Keller Pyrometer Systems - LED / RS485 / USB
Optical pyrometer - CellaCast PA 81 - Keller Pyrometer Systems - LED / RS485 / USB
Optical pyrometer - CellaCast PA 81 - Keller Pyrometer Systems - LED / RS485 / USB - image - 2
Optical pyrometer - CellaCast PA 81 - Keller Pyrometer Systems - LED / RS485 / USB - image - 3
Optical pyrometer - CellaCast PA 81 - Keller Pyrometer Systems - LED / RS485 / USB - image - 4
Add to favorites
Compare this product

Characteristics

Technology
optical
Display
LED
Communication
USB, RS485
Protection level
IP65
Configuration
stationary
Other characteristics
stainless steel, transfer, non-contact, optical
Temperature

Max.: 2,400 °C
(4,352 °F)

Min.: 800 °C
(1,472 °F)

Spectral range

0.95 µm, 1.05 µm

Response time

20 ms

Description

Product overview:
The CellaCast PA 81 is a two-colour pyrometer designed for non-contact temperature measurement of liquid metals in casting channels, transfer ladles and pouring ladles. It features a separate optical measuring head and a fibre-optic cable that are immune to electromagnetic interference and usable up to 250 °C ambient temperature without cooling, making the system suitable for confined or difficult-to-access installation points.

Special features:
  • Measuring range 800 to 2,400 °C
  • Wear-free, maintenance-free measuring system for melting and holding furnaces, cupolas and blast furnaces
  • ATD function for filtering the temperature of slag-free and oxide-free metal surfaces
  • Two-colour measuring method for interference-free readings in dust and vapour
  • High-resolution optics for reliable measurement at long distances
  • Measuring head and fibre-optic cable heat resistant up to 250 °C


Key properties / Version data:
Measuring range: 800 - 2400 °C
Focus distance: 0.2 m - ∞
Sighting option: Laser pilot light
Measuring field shape: round
Distance ratio: 190 : 1
Measuring head (standard): PA 41.01
Measuring principle: two-colour

Measurement parameters:
Measuring range: 800 - 2400 °C
Sensor: Double photodiode
Spectral range: 0.95 / 1.05 µm
Response time t98: ≤ 20 ms (T > 950 °C)
Measurement uncertainty: 1.5 % of temperature reading [°C]
Repeatability: 3 K
Temperature coefficient: 0.05 %/K
Resolution current output: 0.2 K + 0.03 % of selected range
Resolution interface: 0.1 K
Resolution display: 1 K

Optical variants:
Measuring heads: PA 41.01 (M30): Focusing 0.2 m - ∞

Electrical parameters:
Analog output: 0(4) - 20 mA linear, switchable, scalable (≤ 500 Ω)
Analog input: 0 - 10 V
Switching outputs: 2 x Open Collector 24 V DC, ≤ 30 mA
Switching inputs: 2 x up to 24 V
Interface: USB, RS 485
Power supply: 24 V DC +10 % / -20 %
Current consumption: ≤ 175 mA (24 V DC)

Features:
Sighting option: Laser pilot light
Display: 4-digit red LED, digit height 8 mm
Status display: 2 x LED
Control elements: 3 buttons

General parameters:
Connection: M12 thread 8-pin
Ambient temperature: Electronics 0 - 65 °C; Measuring head up to 250 °C
Storage temperature: -20 - +80 °C
Permissible humidity: 95 % r.H. max. (non-condensing)
Dimensions: Electronics Ø 65 mm x 187 mm; Measuring head depending on type
Housing: Stainless steel V2A (1.4305)
Protection class: IP 65 (DIN 40050)
Weight: approx. 0.9 kg

Adjustable parameters:
  • Measuring range and measured variable
  • Scale of analogue input and output signals
  • Smoothing filter and memory operation mode
  • Hold time of memory
  • Emissivity and transmittance
  • Compensation of reflected ambient radiation
  • Limits and operating mode of alarm contacts
  • Parameters of the ATD function and linearization
  • Status display configuration and simulation of current/temperature
  • Temperature unit °C/°F
  • Measurement channel selection: two-colour, single-colour 1, single-colour 2
  • Threshold level of contamination monitoring


Functions:
  • Overtemperature signal: if internal temperature > 80 °C the analogue output shows > 20.5 mA
  • Service function: simulation of a measured value or a current signal
  • ATD (Automatic Temperature Detection): automatic detection for discontinuous processes


Scope of delivery:
  • Pyrometer CellaCast PA
  • Connection cable VK 02/A (5 m)
  • Measuring head
  • USB cable VK 11/D (1.8 m)
  • Software CellaView
  • Short manual
  • * Fibre-optic cable must be ordered separately


Software:
CellaView

Technical specifications:
  • Model: CellaCast PA 81
  • Measuring range: 800 - 2400 °C
  • Spectral range: 0.95 / 1.05 µm
  • Response time (t98): ≤ 20 ms (T > 950 °C)
  • Accuracy: 1.5 % of temperature reading
  • Repeatability: 3 K
  • Distance ratio: 190 : 1
  • Focus distance: 0.2 m - ∞
  • Measuring head: PA 41.01
  • Measuring principle: Two-colour
  • Analog output: 0(4) - 20 mA
  • Interfaces: USB, RS 485
  • Power supply: 24 V DC (+10 % / -20 %)
  • Operating ambient temperature (electronics): 0 - 65 °C; measuring head up to 250 °C
  • Housing: Stainless steel V2A (1.4305)
  • Protection class: IP65
  • Weight: approx. 0.9 kg
  • Included software: CellaView

Catalogs

No catalogs are available for this product.

See all of Keller Pyrometer Systems‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

Shenzhen International Semiconductor & IC Exhibition
Shenzhen International Semiconductor & IC Exhibition

9-11 Sep 2026 Shenzhen (China)

Inter Foundry 2026
Inter Foundry 2026

10-12 Sep 2026 Coimbatore (India)

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.