Product overviewThe CellaCast PA 83 pyrometer is designed to measure the temperature of molten metals on automatic casting machines (plug and ladle casting). Its rectangular measuring field provides reliable readings even when the pouring stream shifts within the field.
Key features- Measuring range: 650 to 1,700 °C (also available in other segments up to 2,400 °C)
- Wear-free, maintenance-free optical measuring system for pouring-stream temperature measurement
- Rectangular measuring field for reliable measurement with fluctuating stream position
- ATD function for automatic recording and monitoring of temperature per casting
- Two-colour measuring method for interference-free measurement in presence of dust and vapour
- Through-the-lens sighting or video camera option for alignment and monitoring
- Large, bright LED display
Measuring field / Measuring field calculator summaryMeasuring distance mm - Measuring field width mm - Measuring field height mm
0.00 mm - 19.00 mm - 19.00 mm
16.00 mm - 18.60 mm - 18.31 mm
32.00 mm - 18.19 mm - 17.62 mm
48.00 mm - 17.79 mm - 16.93 mm
64.00 mm - 17.38 mm - 16.24 mm
80.00 mm - 16.98 mm - 15.55 mm
96.00 mm - 16.57 mm - 14.86 mm
112.00 mm - 16.17 mm - 14.17 mm
128.00 mm - 15.76 mm - 13.48 mm
144.00 mm - 15.36 mm - 12.79 mm
160.00 mm - 14.96 mm - 12.10 mm
176.00 mm - 14.55 mm - 11.41 mm
192.00 mm - 14.15 mm - 10.71 mm
208.00 mm - 13.74 mm - 10.02 mm
224.00 mm - 13.34 mm - 9.33 mm
240.00 mm - 12.93 mm - 8.64 mm
256.00 mm - 12.53 mm - 7.95 mm
272.00 mm - 12.12 mm - 7.26 mm
288.00 mm - 11.72 mm - 6.57 mm
304.00 mm - 11.32 mm - 5.88 mm
320.00 mm - 10.91 mm - 5.19 mm
336.00 mm - 10.51 mm - 4.50 mm
352.00 mm - 10.10 mm - 3.81 mm
368.00 mm - 9.70 mm - 3.12 mm
384.00 mm - 9.29 mm - 2.43 mm
Optical variants & lensesRectangular measuring field; available lenses include:
- Standard objective PZ 20.01: focus 0.4 m – ∞
- Close-up PZ 20.03: focus 0.2 m – 0.4 m
- Wide-angle PZ 20.05: focus 0.2 m – ∞
- Telephoto I PZ 20.06: focus 1.2 m – ∞
- Telephoto II PA 20.06: focus 0.6 m – ∞
- Objective F50 PZ 20.08: focus 0.3 m – ∞
- Macro PA 40.01 (for 750–2400 °C): focus 0.086 m – 0.115 m
Measuring principle & detectionTwo-colour measuring principle (ratio method) with double photodiode; spectral ranges 0.95 µm / 1.05 µm.
Alignment / SightingThrough-the-lens sighting, laser pilot light and optional video camera for alignment and monitoring. Video output (camera model): Composite PAL, 1 Vpp, 75 Ω.
Functions- ATD (Automatic Temperature Detection) for discontinuous processes
- Overtemperature signalling (internal temperature thresholds)
- Simulation/service functions for measured value or current signal
- Contamination monitoring with adjustable thresholds
Scope of delivery (typical)- Pyrometer CellaTemp PA
- Connection cable VK 02/A (5 m)
- Video cable VK 02/F (5 m) for camera models
- USB cable VK 11/D (1.8 m)
- Software CellaView and short manual
NotesMultiple versions available (AF 1, AF 3, AF 10, AF 11, AF 13) with different measuring ranges and focus distances. Several accessory and mounting options exist for electrical and mechanical integration.
Technical specifications- Measuring range: 650–2400 °C in segments (common: 650–1700 °C; 750–2400 °C)
- Sensor: Double photodiode
- Spectral range: 0.95 µm / 1.05 µm
- Response time t98: ≤ 10 ms (depending on range and thresholds)
- Measurement uncertainty: 1.5 % of reading [°C]
- Repeatability: 3 K
- Temperature coefficient: 0.05 %/K
- Resolution current output: 0.2 K + 0.03 % of selected range
- Resolution interface: 0.1 K; display resolution: 1 K
- Analog output: 0(4)–20 mA, linear, switchable, scalable (≤ 500 Ω)
- Analog input: 0–10 V
- Switching outputs: 2 × open collector 24 V DC, ≤ 30 mA
- Switching inputs: 2 × to 24 V
- Interfaces: USB, RS 485
- Power supply: 24 V DC +10 % / -20 %; current ≤ 175 mA
- Display: 4-digit red LED, digit height 8 mm; 2 × status LEDs; 3 control buttons
- Video output (camera model): Composite PAL, 1 Vpp, 75 Ω
- Connection: M12 thread 8-pin
- Operating ambient temperature: 0–65 °C; storage: -20–+80 °C
- Permissible humidity: max. 95 % r.H. (non-condensing)
- Dimensions: Ø 65 mm × 220 mm (max. 277 mm)
- Housing: Stainless steel V2A (1.4305)
- Protection class: IP 65 (DIN 40050)
- Weight: approx. 0.9 kg
- Measuring modes: two-colour (plus selectable single-colour 1/2)
- Adjustable parameters: measuring range, emissivity, transmittance, smoothing, ATD settings, alarm limits, linearization, LED status, simulation, °C/°F; camera models: white balance and TBC
- Software: CellaView