Product overviewThe CellaTemp® PX 31 is a digital fibre-optic pyrometer designed for non-contact temperature measurement from 550 to 2500 °C. The system uses a separated optical measuring head connected to the electronics via a fibre optic cable, enabling measurements in electromagnetically noisy environments and in confined spaces. The measuring head tolerates ambient temperatures up to 250 °C without additional cooling.
Special features- Measuring range variants up to 3000 °C
- IO-Link interface for digital communication
- Focusable, interchangeable lenses for precise distance adjustment
- Broadband anti-reflective precision optics
- Readable red LED display with remote visibility
- All parameters configurable via front keypad
- Diagnostic test current output
- 1 analogue output (0/4–20 mA) and 2 switching outputs
- Configurable source and ATD (automatic temperature detection) function
Properties / selectable options- Measuring range (typical): 550–2500 °C (other ranges up to 3000 °C available)
- Focus distance examples: 0.2 m–∞; 0.12 m–∞; 0.033–0.045 m
- Sighting: Laser pilot light
- Example versions: CellaTemp® PX 31 AF 11; PX 31 AF 21; PX 31 AF 22
Technical data- Sensor: Photodiode
- Spectral range: 0.78–1.06 µm
- Response time t98: ≤ 50 ms (T > 600 °C); ≤ 2 ms (T > 800 °C)
- Measurement uncertainty: 0.75 % of reading
- Repeatability: 2 K
- Temperature coefficient: 0.05 %/K
- Resolution (analogue output): 0.2 K + 0.03 % of range
- Resolution (interface): 0.1 K; display resolution: 1 K
Optical variants- Measuring heads for 550–2500 °C: PA 41.01 (M30) focus 0.2 m–∞; PA 41.05 (M16) focus 0.12 m–∞; PZ 41.18 (M16) focus 0.033–0.045 m
- Measuring head for 700–3000 °C: PA 41.02 (M16) focus 0.5 m–∞
Electrical parameters- Analogue output: 0(4)–20 mA, linear, switchable, scalable
- Load resistance: ≤ 500 Ω
- Switching outputs: 2 × Open Collector 24 V DC, ≤ 150 mA
- Interface: IO‑Link
- Supply: 24 V DC (+10 % / -20 %); current consumption ≤ 175 mA
Features- Sighting: Laser pilot light
- Display: 4‑digit red LED, digit height 8 mm
- Status: 4 LEDs
- Control: 3‑button keypad
General parameters- Connection: M12, 5‑pin
- Ambient temperature (electronics): 0–65 °C; measuring head: up to 250 °C (no cooling)
- Storage: -20–+80 °C
- Humidity: ≤ 95 % RH, non‑condensing
- Housing: Stainless steel V2A (1.4305); protection class IP65
- Dimensions: electronics Ø 65 mm × 187 mm; measuring head depends on type
- Weight: approx. 0.9 kg
Adjustable parameters- Analogue output mode and scaling
- Smoothing filter, memory mode and hold time
- Emissivity and transmittance
- Alarm limits and operating mode for switching outputs
- ATD function parameters; simulation of current and temperature; unit °C/°F
Functions- Overtemperature signal (internal temperature > 75 °C)
- Service function: simulate measured value or current signal
Scope of delivery- Pyrometer CellaTemp® PX
- Connection cable VK 02/L AF 1 (5 m)
- Measuring head
- Short manual
- * Fibre optic cable ordered separately
SoftwareSW 50
Specifications- Model family: CellaTemp® PX
- Main measuring range: 550–2500 °C
- Spectral range: 0.78–1.06 µm
- Sensor: Photodiode
- Analogue output: 0(4)–20 mA
- Interface: IO‑Link
- Switching outputs: 2 × Open Collector 24 V DC
- Response time: ≤ 50 ms (T > 600 °C), ≤ 2 ms (T > 800 °C)
- Measurement uncertainty: 0.75 % of reading
- Protection class: IP65
- Ambient temperature (electronics): 0–65 °C; measuring head up to 250 °C
- Housing: Stainless steel V2A (1.4305)
- Weight: approx. 0.9 kg