Components:- Pyrometer CellaTemp PK 11 BF 2
- Mounting PK 01-027
- Cable VK 02/L AF 1
Special features:- Compact infrared thermometer with bright LED display and control panel
- Broadband anti-reflective precision lens
- Analogue output and IO-Link interface
- Mounting fitting with flow-optimized air purge to avoid contamination with minimal air consumption
- Flexibly adjustable holding device
Main data (summary):Version: CellaTemp PK 11-K001
Measuring range: 0 - 1000 °C
Target size: 11 mm
Focus distance: 0.3 m
Shape of the measuring field: round
Measuring principle: one-colour
Measurement parameters:Measuring range: 0 - 1000 °C
Sensor: Thermopile
Spectral range: 8 - 14 µm
Response time t90: ≤ 60 ms
Measurement uncertainty: 0.75 % of temperature reading [°C] plus 2.0 K
Repeatability: 1 K
Temperature coefficient: 0.1 K/K (T < 250 °C); 0.04 %/K (T > 250 °C)
Resolution current output: 0.1 K + 0.005 % of selected measuring span
Resolution interface: 0.1 K
Resolution display: 0.1 K < 200 °C; 1 K ≥ 200 °C
Electrical parameters:Analog output: 0(4) - 20 mA linear, switchable, scalable
Resistance: ≤ 500 Ω
Switching output: 2 x PNP Open Collector 24 V DC, 2 x 150 mA max.
Interface: IO-Link V1.1.3
Power supply: 18 - 32 V DC
Current consumption: ≤ 50 mA at 24 V DC
Features:Display: 4-digit red LED, digit height 8 mm
Status display: 3 x LED
Control elements: 3 buttons
General parameters:Connection: M12 thread 5-pin connection (A-coding)
Ambient temperature: 0 - 65 °C
Storage temperature: -20 - +80 °C
Permissible humidity: 95 % r.H. max. (non-condensing)
Dimensions: Ø 30 x 185 mm (without plug)
Housing: Stainless steel V2A (1.4305)
Protection class: IP 65 acc. to DIN 40050
Weight: approx. 0.4 kg
Adjustable parameters:Analog output 0/4 - 20 mA; Scaling of the analogue output; Emissivity via quick adjustment; Transmission of the protective glass; Damping time constant; Hold time of the maximum value memory; Operating mode, source and switching point, switch-on and switch-off delay of the switching contacts; Temperature correction for process-specific influences using interpolation points (X/Y pairs); Vitality indicator; Service parameters; Reset to factory setting; Key lock; Display of temperature or "run" in the display; Temperature unit °C/°F; Simulation of temperature
Functions:Overtemperature signal: Signal display at an internal temperature > 75 °C
Service function: Simulation of a measured value
Diagnostic function: Indicates reverse polarity, overload and incorrect supply voltage
Reverse polarity protection: for power supply, analogue output and switching output
Scope of delivery:Infrared thermometer CellaTemp PK
Manual (short)
2 fixing nuts
Software:SW 50
Measuring field (selected):Measuring distance / Measuring field diameter (examples):
0.00 mm / 16.50 mm
36.00 mm / 17.16 mm
72.00 mm / 17.82 mm
108.00 mm / 18.48 mm
144.00 mm / 19.14 mm
180.00 mm / 19.80 mm
900.00 mm / 33.00 mm
Technical specifications:- Model: PK 11-K001
- Measuring range: 0 - 1000 °C
- Target size (nominal): 11 mm
- Focus distance: 0.3 m
- Spectral range: 8 - 14 µm
- Response time (t90): ≤ 60 ms
- Measurement uncertainty: 0.75 % of reading + 2.0 K
- Analog output: 0(4)-20 mA (linear, scalable)
- Interface: IO-Link V1.1.3
- Power supply: 18 - 32 V DC
- Protection class: IP65
- Housing: Stainless steel V2A (1.4305)
- Dimensions: Ø 30 x 185 mm
- Weight: approx. 0.4 kg