KLN manufactures various cleaning machines acc. to ATEX (ATmosphère EXplosibles) for the use of combustible liquids. The cleaning machines can be used separately or in combination with other methods.
Cleaning machines for combustible liquids with a flash point of FP>55°C
In the ordinance on industrial safety and health (BetrSichV) combustible liquids with an FP>55°C are no longer registered. The requirement to safety for handling combustible liquids, however, remains valid.
The safety data sheets inform on all data relevant for safety when handling the respective combustible liquid. In appendix II of the REACH directive (EC) No. 1907/2006 the content of the safety data sheets is determined.
The cleaning tanks must be operated at a well ventilated place. The MAK (maximum working place concentration) values must be observed.
The combustible cleaning agent can be filled in directly into the tanks. The ultrasonic generators are set up separately. A safety thermostat (setting 15°C below the flash point) controls the adherence to a max. temperature and in case of excess temperature it switches the machine off. The cover included in the delivery avoids emissions from the tank during standstills.
The machines can also be used in connection with aqueous cleaning methods.
heating
extraction
cooling tube
ultrasonic frequencies 30 and/or 40 kHz
automation system
product carrier