General purpose accelerometer B07B01
uniaxialIEPEwith TEDS

General purpose accelerometer - B07B01 - LNS Dynamics LLC - uniaxial / IEPE / with TEDS
General purpose accelerometer - B07B01 - LNS Dynamics LLC - uniaxial / IEPE / with TEDS
Add to favorites
Compare this product

Characteristics

Number of axes
uniaxial
Technology
IEPE
Other characteristics
for general purposes, for machine condition monitoring, for continuous structure monitoring, constant-current, with TEDS, with analog output, ultra-light, IP68
Frequency

Max.: 6,000 Hz

Min.: 1 Hz

Description

Product overview
  • General-purpose uniaxial IEPE accelerometer B07B01
  • Sensitivity: 200 mV/g
  • Range: ±25 g
  • Frequency response (5%): 1–6000 Hz
  • Temperature range: -40 to 120 °C
  • Connector/mount: 10-32 (side) and M5 (side); female mounting


Key features
  • IEPE output suitable for vibration measurement and condition monitoring
  • Stainless steel housing with laser-welded IP68 sealing
  • TEDS option available
  • Lightweight: 14.5 g


Technical specifications
  • Sensitivity: 200 mV/g
  • Range: ±25 g
  • Frequency range [5%]: 1–6000 Hz
  • Frequency range [10%]: 0.5–8000 Hz
  • Resonant frequency: ≥26 kHz
  • Broadband resolution: 0.00005 g rms
  • Linearity: 1%
  • Transverse sensitivity: ≤5%
  • Excitation voltage: 20–30 Vdc
  • Constant current excitation: 2–20 mA
  • Output bias voltage: 8–12 Vdc
  • Output impedance: ≤100 Ω
  • Max acceleration: 200 g
  • Max shock: 500 g
  • Temperature range: -40 to 120 °C
  • Sensitivity temperature coefficient: -0.1 %/°C
  • Sealing: Laser welding, IP68
  • Housing material: Stainless steel
  • Output connector: 10-32 (side) and M5 (side)
  • Mounting: 10-32 female, M5 female
  • Weight: 14.5 g
  • TEDS: Optional


Typical applications
  • Machinery condition monitoring
  • Vibration analysis on test benches
  • Structural monitoring and modal testing
  • Portable and embedded measurement systems


Mounting & connection
  • Female 10-32 or M5 mounting for threaded installation
  • Side connectors for compact installations
  • Recommended excitation: constant-current IEPE supply 2–20 mA, 20–30 Vdc